Magnetic Stimulation of One-Dimensional Neuronal Cultures

Similar presentations


Presentation on theme: "Magnetic Stimulation of One-Dimensional Neuronal Cultures"— Presentation transcript:

1 Magnetic Stimulation of One-Dimensional Neuronal Cultures
Assaf Rotem, Elisha Moses  Biophysical Journal  Volume 94, Issue 12, Pages (June 2008) DOI: /biophysj Copyright © 2008 The Biophysical Society Terms and Conditions

2 Figure 1 A model of TvMS of one-dimensional neuronal cultures. (A) A circular coil (blue circles) is positioned 5mm above one-dimensional neuronal ring cultures (blue disk). The rings are parallel to and concentric with the coil, which discharges a maximum voltage load of 5000V from the MS capacitor. This creates a pulse of magnetic field which is oriented along the red lines (the mild deformation of magnetic field lines near the blue disk is due to the presence of a metal coating on the disk as is the case with our coverslips; see Methods). By Faraday's law, the induced electric field lies on planes that are parallel to the plane of the coil along rings concentric with the coil, and depends on the change of magnetic flux through these rings. (B) A closeup of the horizontal cross-section along the plane of the ring cultures in panel A. The relative value of the electric field is color-coded, and its direction depicted by white arrows. Larger rings enclose a larger area of flux and therefore the electric field induced at those rings is stronger. (C) The membrane potential of a neurite that is 0.2-mm long (green) compared to that of a neurite 6-mm long (blue). Both neurites have a length constant of λ=0.3mm. The induced electric field (300V/m) is parallel to the neurite and the membrane potential peaks at the neurite ends. The membrane potential of neurites that are shorter than their length constant is simply linear with their length L, while the membrane potential of neurites that are longer than λ is governed by λ. The passive time constant is τ<1μs (see Theoretical Background). Biophysical Journal  , DOI: ( /biophysj ) Copyright © 2008 The Biophysical Society Terms and Conditions

3 Figure 2 Experimental setup. (A) A bright field image of a patterned 24-mm coverslip. The white areas are neuronal cultures. The photographed pattern consists of ring cultures in arcs of different length. Radial lines serve as a control (see Methods). Each ring's width is ∼200μm. (B and C) An inverted microscope images fluorescent dyes sensitive to calcium transients of neurons reacting to magnetic pulses. The magnetic coil (blue circles) is located 5mm concentrically above the neuronal ring culture, which is placed in a petri dish (blue outline). A pickup coil (red circle) positioned on the circumference of the petri dish measures the voltage induced by the magnetic pulse. (D) The measured dynamics of the magnetic stimulator coil (MS capacitor voltage load=5000kV) as integrated from the pickup coil. Induced electric field (calculated for a ring radius of 14mm) is depicted in green while the magnetic field is depicted in blue. Biophysical Journal  , DOI: ( /biophysj ) Copyright © 2008 The Biophysical Society Terms and Conditions

4 Figure 3 Fluorescent measurements of calcium transients. (A, Top) Image taken with a low-magnification stereoscope of a 30-mm coverslip containing four concentric ring cultures (14, 13, 12, and 11mm in radius) that were imaged during magnetic stimulation. The field of view of the high-magnification imaging microscope is marked with a green circle. (A, Bottom) A single fluorescence image from the field of view of the imaging microscope. Numbered boxes denote the regions of interest for which the average intensity is displayed in panel B. (B) The ΔF/F (i.e., the ratio between transient and background fluorescence) intensities of each green region in panel A is plotted versus time (blue traces, each trace was normalized according to its maximum amplitude, which was 5–10% ΔF/F in all regions). The exact timing of each of the TvMS pulses is marked with a dashed vertical black line and the amplitude of the magnetic pulse in Tesla is denoted above each line. Both spontaneous activity and evoked activity is observed. (C) The responses of each region to TvMS, clustered according to the strength of the stimulation. Each trace is taken from panel B during the 4s that follow each stimulation. As illustrated in Fig. 5 A, ring cultures with larger radius (regions #1 and #2) respond to weaker stimulations and vice versa. The measured magnetic field threshold in this case is 1.3 T for regions #1 and #2, 1.7 T for region #3, and 2.7 T for region #4. Biophysical Journal  , DOI: ( /biophysj ) Copyright © 2008 The Biophysical Society Terms and Conditions

5 Figure 4 The success rate of TvMS for different lengths of cultures. Black line depicts the normal cumulative distribution that fits the data, with the parameters presented in the figure. Biophysical Journal  , DOI: ( /biophysj ) Copyright © 2008 The Biophysical Society Terms and Conditions

6 Figure 5 (A) Measurements of magnetic field thresholds in the experiment. The y-value of each point is the magnetic field threshold measured for a specific ring culture while the x-value of each point is the radius of that specific culture. The color coding denotes both the electric field threshold and the probability to measure an excitation. Regions of equal colors confine similar values of electric field threshold. Warmer colors (according to the color-bar in the figure) denote a higher probability to measure these thresholds (as described in Methods). The white frame outlines the experimentally accessible phase space. (B) The cumulative sum of the actual density of data points in each color region in panel A. For each value of electric field threshold (corresponding to similar color regions in A), the probability to measure a threshold as high as this value is plotted. Red line depicts the normal cumulative distribution that fits the data, with the parameters presented in the figure. (Inset) For each value of electric field threshold, the probability to measure a threshold at a bin around this value is plotted. Red line depicts the normal distribution that fits the data, with the same parameters presented in the main figure. Biophysical Journal  , DOI: ( /biophysj ) Copyright © 2008 The Biophysical Society Terms and Conditions

7 Figure 6 Single neuron response. (A) Fluorescent analysis of video taken from a 10× field of view. The image is the average intensity of the fluorescent signal across four events of 450 frames each. Green contour encloses areas that were spontaneously active during the first event (at 4.5μM of CNQX, the highest concentration at which spontaneous bursting activity persisted across the whole culture). Red points represent locations that responded to TvMS during the last three events (at CNQX concentration of 9μM, for which no bursting activity was observed). (B) Traces of the fluorescence signal (in units of the relative change of intensity as a fraction of the background intensity) during the four events: green traces (top row), average intensity of all coordinates enclosed in the green contour; and red traces (bottom row), average intensity of all red coordinates. TvMS pulses are marked with a dashed vertical line, with the intensity of the induced electric field indicated in V/m. Biophysical Journal  , DOI: ( /biophysj ) Copyright © 2008 The Biophysical Society Terms and Conditions

8 Figure 7 Modeling the membrane potential of a finite neurite undergoing magnetic stimulation. Color-coded maps of the maximal membrane potential that is reached in response to a 100V/m induced electric field, portrayed as a function of λ and L. Each map was calculated for a different τ, with the top row corresponding to axons and the bottom row corresponding to dendrites. Dashed contours represent the biologically relevant ranges of L and λ in axons (ellipsoid, top row) and dendrites (half-circle, bottom row). The maximal membrane potential that can be attained in dendrites is approximately half what can be attained by axons. The membrane potential in each of the maps was calculated as described in the Appendix. Potential contour values are in mV. Biophysical Journal  , DOI: ( /biophysj ) Copyright © 2008 The Biophysical Society Terms and Conditions


Download ppt "Magnetic Stimulation of One-Dimensional Neuronal Cultures"