Innovative Filtration Solution Laboratory Filtration Product Technical Details
2
Axiva Strength An Eight years old company. A dedicated team of 70 professionals. In-house Analytical Labs for Quality consistency and R & D. “AXIVA ” brand Available in more than 45 countries across the globe. Every filter box is supplied with ‘COA’ inside. Sterilization certificate available for every batch with protocol
3
Quality Assurance Quality Assurance Lab is studded with all modern instruments including “HPLC” Trained & experienced Scientists are working to ensure quality in each & every filter.
5
Syringe Filters – Non Sterile Nylon PTFE PVDF CA PES MCE Glass fibre Double Layered Triple Layered
6
Nylon Syringe Filters - Non Sterile Applications : HPLC Solvents Sample Filtration Mobile phase separation For aqueous as well as organic solvent filtration Available sizes : 4 mm, 13 mm, 25 mm, 33 mm Technical Specification : Wetability : Hydrophilic Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm Extractable (NVR) : Very low (within limit as specified in USP XXIV) Initial Water flow rate : 35.4 ml/min for 0.2 μm & 67.2 ml/min for 0.45 μm (at 10 psi for 25 mm) Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm Target Market : Pharma – QC & R&D Available Porosity : 0.22 & 0.45 microns
7
PTFE Syringe Filters - Non Sterile Applications : For Analytical and Research applications & for Air sampling. Used under extreme chemical or temp. Conditions. For non- aqueous base organic solvent filtration Ideal for filtration of highly aggressive colloidal solutions. Available sizes : 4 mm, 13 mm, 25 mm, 33 mm Technical Specification : Wettability : Hydrophobic Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm Extractable (NVR) : Very low (within limit as specified in USP XXIV) Initial Water flow rate : 21 ml/min for 0.2 μm & 29.3 ml/min for 0.45 μm (at 10 psi for 25 mm) Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
8
PVDF Syringe Filters - Non Sterile Applications : For Analytical and Research applications. For aqueous as well as organic solvent filtration Filtration of difficult filter solutions. Available sizes : 4 mm, 13 mm, 25 mm, 33 mm Technical Specification : Wettability : Hydrophilic Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm Extractable (NVR) : Very low (within limit as specified in USP XXIV) Initial Water flow rate : 41.3 ml/min for 0.2 μm & 94.3 ml/min for 0.45 μm (at 10 psi for 25 mm) Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
9
CA Syringe Filters - Non Sterile Applications : Suitable for filtration of Protein solutions. For aqueous as well as organic solvent filtration Available sizes : 4 mm, 13 mm, 25 mm, 33 mm Technical Specification : Wettability : Hydrophilic Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm Extractable (NVR) : Very low (within limit as specified in USP XXIV) Initial Water flow rate : 38.4 ml/min for 0.2 μm & 72.3 ml/min for 0.45 μm (at 10 psi for 25 mm) Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
10
PES Syringe Filters - Non Sterile Applications : For Analytical and Research applications. Recommended for aqueous as well as organic solvent filtration Filtration of difficult filter solutions. Available sizes : 4 mm, 13 mm, 25 mm, 33 mm Technical Specification : Wettability : Hydrophilic Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm Extractable (NVR) : Very low (within limit as specified in USP XXIV) Initial Water flow rate : 46.2 ml/min for 0.2 μm & 68.0 ml/min for 0.45 μm (at 10 psi for 25 mm) Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
11
MCE Syringe Filters - Non Sterile Applications : For Analytical and Research applications. Recommended for aqueous as well as organic solvent filtration Filtration of difficult filter solutions. Available sizes : 4 mm, 13 mm, 25 mm, 33 mm Technical Specification : Wettability : Hydrophilic Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm Extractable (NVR) : Very low (within limit as specified in USP XXIV) Initial Water flow rate : 46.2 ml/min for 0.2 μm & 68.0 ml/min for 0.45 μm (at 10 psi for 25 mm) Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
12
Glass Fiber Syringe Filters - Non Sterile Applications : Sample cleaning Particle removal For High throughput Removes particulate that interferes with UV/VIS spectrophotometric analysis Can be used alone or in series with another Axiva syringe filter Available sizes : 13 mm, 25 mm, 33 mm Technical Specification : Effective Filtration Area : 0.8 cm for 13mm & 3.9 for 25mm Sample Volume : <20ml for 13mm & <150 ml for 25mm Typical Hold-Up Volume (with air purge) : <20μl for 13mm and <100μl for 25mm Maximum Operating Temperature : 82°C (180°F) at 2.1 bar (210 kPa, 30 psi) Typical Water Flow Rate : 795 ml/min at 1.0 bar
13
Double Layered Syringe Filters - Non Sterile Applications : Sample cleaning Particle removal For High throughput Removes particulate that interferes with UV/VIS spectrophotometric analysis Can be used alone or in series with another Axiva syringe filter Available sizes : 13 mm, 25 mm Technical Specification : They are widely applicable for filtration of colloidal solutions. Also used in the filtration of typical filter solution (viscous solutions)
14
Triple Layered Syringe Filters - Non Sterile Applications : Eliminates sample contamination Requires less hand pressure, even with the most difficult samples Processes three to seven times more sample volume Available sizes : 25 mm Technical Specification : They are widely applicable for filtration of colloidal solutions. Also used in the filtration of typical filter solution (viscous solutions)
15
Sterilized Syringe Filters Nylon PTFE PVDF CA PES MCE Double Layered Triple Layered
16
Nylon Syringe Filters - Sterile Applications : HPLC Solvents Sample Filtration Mobile phase separation For aqueous as well as organic solvent filtration Available sizes : 4 mm, 13 mm, 25 mm, 33 mm Technical Specification : Wettability : Hydrophilic Sterilization : ETO Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm Extractable (NVR) : Very low (within limit as specified in USP XXIV) Initial Water flow rate : 35.4 ml/min for 0.2 μm & 67.2 ml/min for 0.45 μm (at 10 psi for 25 mm) Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
17
PTFE Syringe Filters - Sterile Applications : For Analytical and Research applications & for Air sampling. Used under extreme chemical or temp. Conditions. For non- aqueous base organic solvent filtration Ideal for filtration of highly aggressive colloidal solutions. Available sizes : 4 mm, 13 mm, 25 mm, 33 mm Technical Specification : Wettability : Hydrophobic Sterilization : ETO Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm Extractable (NVR) : Very low (within limit as specified in USP XXIV) Initial Water flow rate : 21 ml/min for 0.2 μm & 29.3 ml/min for 0.45 μm (at 10 psi for 25 mm) Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
18
PVDF Syringe Filters - Sterile Applications : For Analytical and Research applications. For aqueous as well as organic solvent filtration Filtration of difficult filter solutions. Available sizes : 4 mm, 13 mm, 25 mm, 33 mm Technical Specification : Wettability : Hydrophilic Sterilization : ETO Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm Extractable (NVR) : Very low (within limit as specified in USP XXIV) Initial Water flow rate : 41.3 ml/min for 0.2 μm & 94.3 ml/min for 0.45 μm (at 10 psi for 25 mm) Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
19
CA Syringe Filters - Sterile Applications : Suitable for filtration of Protein solutions. For aqueous as well as organic solvent filtration Available sizes : 4 mm, 13 mm, 25 mm, 33 mm Technical Specification : Wettability : Hydrophilic Sterilization : ETO Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm Extractable (NVR) : Very low (within limit as specified in USP XXIV) Initial Water flow rate : 38.4 ml/min for 0.2 μm & 72.3 ml/min for 0.45 μm (at 10 psi for 25 mm) Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
20
PES Syringe Filters - Sterile Applications : For Analytical and Research applications. Recommended for aqueous as well as organic solvent filtration Filtration of difficult filter solutions. Available sizes : 4 mm, 13 mm, 25 mm, 33 mm Technical Specification : Wettability : Hydrophilic Sterilization : ETO Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm Extractable (NVR) : Very low (within limit as specified in USP XXIV) Initial Water flow rate : 46.2 ml/min for 0.2 μm & 68.0 ml/min for 0.45 μm (at 10 psi for 25 mm) Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
21
MCE Syringe Filters - Sterile Applications : For Analytical and Research applications. Recommended for aqueous as well as organic solvent filtration Filtration of difficult filter solutions. Available sizes : 4 mm, 13 mm, 25 mm, 33 mm Technical Specification : Wettability : Hydrophilic Sterilization : ETO Effective filtration area : 0.1cm² for 4mm, 0.8 cm² for 13mm, 3.9 cm² for 25mm & 4.6 cm² for 33mm Hold up volume : <10 μl for 4mm, < 20 μl for 13mm, < 50 μl for 25mm & < 80μl for 33mm (after air purge) Integrity Test : Water Bubble point > 50psi for 0.2 μm & >30 psi for 0.45 μm Extractable (NVR) : Very low (within limit as specified in USP XXIV) Initial Water flow rate : 46.2 ml/min for 0.2 μm & 68.0 ml/min for 0.45 μm (at 10 psi for 25 mm) Filtration Volume : < 1ml for 4mm, 1-10ml for 13mm, 10-100ml for 25mm & 30-150 ml for 33mm
22
Double Layered Syringe Filters - Sterile Applications : Sample cleaning Particle removal For High throughput Removes particulate that interferes with UV/VIS spectrophotometric analysis Can be used alone or in series with another Axiva syringe filter Available sizes : 13 mm, 25 mm Technical Specification : They are widely applicable for filtration of colloidal solutions. Also used in the filtration of typical filter solution (viscous solutions)
23
Triple Layered Syringe Filters - Sterile Applications : Eliminates sample contamination Requires less hand pressure, even with the most difficult samples Processes three to seven times more sample volume Available sizes : 25 mm Technical Specification : They are widely applicable for filtration of colloidal solutions. Also used in the filtration of typical filter solution (viscous solutions)
24
Air Vent Filters PTFE
25
Air Vent Filters Applications : Applicable for small volume venting & degassing Venting bioreactors Fermentation tanks & carboys Sterile gas purging of culture vessel Pharmaceutical vents Laboratory : clean or sterile: gases, solvents, reagents, drying gases Electronics : photo resists, solvents, gases for research Available sizes : 50 mm Technical Specification : Wettability : Hydrophobic Sterilization : ETO Max. Operating Pressure : 60 psi Bubble Point : > 24 psi in 70% IPA Air Flow Rate : 10 NLPM at 50 psi Housing Burst at 25°C : 75 psi (5.17 bar)
26
Membrane Disc Filters Nylon C.N. P.T.F.E. P.E.S
27
Nylon Membrane Filter Applications : Sterilizing filtration of aq. solution & Bioassay Ideal for HPLC solvents Mobile phase separation & Solvent filtration Technical Specification : Color : White Wettability : Hydrophilic Extractable (NVR) : Very low (within limit as specified in USP XXIV) Surface : Plain Operating Temp. : 0 75 C (max) Heat Stability : Maintain integrity for 5 cycles of autoclave at 1210C for 30 minutes Available sizes : 13 mm, 25 mm, 47 mm
28
C.N. Membrane Filter – Non Sterile Applications : Ideal for microbial analysis. Suitable for aqueous and protein filtration. Technical Specification : Color : White Wettability : Hydrophilic Surface : Plain Available sizes : 13 mm, 25 mm, 47 mm, 90 mm
29
C.N. Membrane Filter - Sterile Applications : Ideal for microbial analysis. Suitable for aqueous and protein filtration. Technical Specification : Color : White Wettability : Hydrophilic Surface : Plain Sterilization : ETO Available sizes : 47 mm
30
Gridded Membrane Filters Cellulose Nitrate Sterile (Individually packed)
31
Gridded Membrane Filters - Sterile Applications : Ideal for microbial analysis. Suitable for aqueous & protein filtration and protein analysis Technical Specification : Color : White Wettability : Hydrophilic Surface : Gridded, Black Sterilization : ETO Available sizes : 47 mm
32
PTFE Membrane Filter Applications : For Analytical and Research applications & for Air sampling Used under extreme chemical or temp. Conditions For non- aqueous base organic solvent filtration Ideal for filtration of highly aggressive colloidal solutions Technical Specification : Color : White Wettability : Hydrophobic Extractable (NVR) : Very low (within limit as specified in USP XXIV) Surface : Plain Available sizes : 13 mm, 25 mm, 47 mm, 142 mm
33
PES Membrane Filter Applications : For Protein sampling For aqueous as well as organic solvent filtration Prevent blow through low molecular weight protein Filtration of difficult filter solutions Technical Specification : Color : White Wettability : Hydrophilic Extractable (NVR) : Very low (within limit as specified in USP XXIV) Surface : Plain Heat Stability : Maintain integrity for 5 cycles of autoclave at 121 Degree Celsius for 30 minutes Available sizes : 13 mm, 25 mm, 47 mm, 142 mm
34
Blotting Membranes Nylon C.N In rolls & sheets.
35
C.N. Blotting Membrane Applications : Ideal for Microbiology Analysis Suitable for aq. and protein filtration Recommended for Western Blotting Applicable for low molecular weight proteins. Technical Specification : Wettability : Hydrophilic Maximal Protein/nucleic acid binding : upto 80 -100 μm/cm sq. Available sizes : 100 X 100 mm, 200 X 200 mm, 300 X 300 mm, 300 mm X 3 meters
36
Nylon Blotting Membrane Applications : Ideal for DNA & RNA transfers Recommended for Southern Blotting. Technical Specification : Wettability : Hydrophilic High binding capacity : 99.7% Available sizes : 100 X 100 mm, 200 X 200 mm, 300 X 300 mm, 300 mm X 3 meters
37
Glass Fibre Filters GF/1F GF/3F 2934 AX
38
Environmental Filters for PM 2.5
39
Filter Funnel Plastic Filter Funnel Glass Filter Funnel S.S. Filter Funnel
40
Plastic Filter Funnel Applications : Have three vent on top for dosing. Silicon Cover Provided Technical Specification : Polycarbonate P. P. with silicon ‘O’ ring and cork. Recessed filter support and graduated funnel. Funnel cover can be vented asceptically using disposable PTFE filter. Available sizes : 47 mm
41
Glass Filter Funnel Available sizes : 47 mm
42
S.S. Filter Funnel Available sizes : 47 mm Applications : Provide large filtration area, Unique design for high flow rate. Technical Specification : All Stainless Steel 316 with external S. S. clamp & Neoprene
43
Filter Holders S.S. Filter Holders Plastic Filter Holders
44
S.S. Filter holders Applications : Provide large filtration area, Unique design for high flow rate & Widely compatible. Technical Specification : Body : S. S. 316 Mesh : S. S. 316 Gasket : PTFE Available sizes : 13 mm, 25 mm
45
Plastic Filter holders Applications : Provide large filtration area, Unique design for high flow rate & Widely compatible. Technical Specification : Body : Polycarbonate Transparent Mesh : Polycarbonate Transparent Gasket : Silicone Available sizes : 13 mm, 25 mm
46
Filtration Assembly Single place Three Place Six Place
47
Vacuum Pumps For Single Place Assembly: Maximum Flow : 15 LPM FOR 3 & 6 PLACE ASSEMBLY Maximum Flow : 45 LPM
48
Vacuum Pumps - single place Applications : High product recovery, suitable for Single place filtration assemblies Technical Specification : Maximum vacuum : 23 (in Hg) Maximum Flow : 15 LPM Motor : 1/8 HP Power : 220 - 230 V
49
Vacuum Pumps – 3 & 6 place Applications : High product recovery, For superfine filtration. suitable for high filtration assemblies Technical Specification : Maximum vacuum : 26 (in Hg) Maximum Flow : 45 LPM Motor : 1/4 HP Power : 220 - 230 V
50
Filter Papers Qualitative Filter Papers
51
Filter paper Applications : Filter Papers Ideal for general laboratory filtration and sugar syrup filtrationFilter Papers Technical Specification : Basis Weight : 85-87gsm Retention : Medium crystalline Filter speed : Medium fast GSM : 90 (approx) pH Resolution : Very low Wet strength : High Ash contents : < 0.1% Available sizes : 5.0, 7.0, 9.0, 11.0, 12.5, 15.0, 18.5, 24.0, 32.0
52
Cellulose Extraction Thimbles
53
Applications : Cellulose Extraction Thimbles Frequently used in Soxhlet, Tectator Extractors Located inside of extractor body to extract the solvents for dust sampling.Cellulose Extraction Thimbles Technical Specification : DOP Retention (% @ 0.3 μm) : 99.8 % Maximum Temperature : 120 degree celsius Wall Thickness : 1.5 mm (approx) Available sizes : 22 x 80, 25 x 80, 28 x 80, 30 x 80, 33 x 80, 25 x 100, 28 x 100, 30 x 100, 33 x 100
54
Lateral Flow Membranes & pads For Diagnostic Kits In Roll form
55
Our Edge Continuous improvement and new developments in products with a very efficient and effective R&D deptt Dedicated in-house Analytical labs for Quality consistency Strong and Efficient Marketing Network Highly satisfied customers
56
Why Axiva? Axiva- A brand recognized with highest level of quality Affordable Laboratory Solutions Technical support Technical Documentation for each product QC certification for each batch Very strong marketing network for timely customer support
57
Address: 424,EPIP, Industrial Estate, Sector-53, Phase-III, Kundli, Sonipat Haryana-131028 (INDIA) Phone: +91-11-40578224 Website: www.axivafilters.comwww.axivafilters.com Email: arvind@axivasichem.comarvind@axivasichem.com