Conext RL 3, 4 and 5kVA Grid Tie Inverters Designed for Flexible and Efficient Residential Solar Solutions v3.0.

Similar presentations


Presentation on theme: "Conext RL 3, 4 and 5kVA Grid Tie Inverters Designed for Flexible and Efficient Residential Solar Solutions v3.0."— Presentation transcript:

1 Conext RL 3, 4 and 5kVA Grid Tie Inverters Designed for Flexible and Efficient Residential Solar Solutions v3.0

2 Agenda 1 Schneider Electric’s Bankability 2 Why Conext RL Inverters 3
Conext Designed for Performance 4 Connectivity and Communications 5 Service, Support and Warranty Explain sections – and how long we will speak on each topic. Want people to ask questions during the presentation. I will try to answer them. If I can’t I will get back to you.

3 A partner you can trust for Quality & Reliability
Schneider Electric Bankability – the global specialist in energy management Balanced geographies – FY 2013 sales Year-end 2013 employees North America 25% Asia Pacific 27% Rest of World 18% Western Europe 30% billion € sales in 2013 % of sales in new economies people in 100+ countries of sales devoted to R&D 43 23.6 4-5% Other Schneider Electric brands well-known for Quality and Reliability: A partner you can trust for Quality & Reliability

4 A partner you can trust for Quality & Reliability
Schneider Electric Australia – service and support by a strong local partner A partner you can trust for Quality & Reliability

5 Agenda 1 Schneider Electric’s Bankability 2 Why Conext RL Inverters 3
Conext Designed for Performance 4 Connectivity and Communications 5 Service, Support and Warranty Explain sections – and how long we will speak on each topic. Want people to ask questions during the presentation. I will try to answer them. If I can’t I will get back to you.

6 Schneider Electric Bankability
Why select Conext RL? Schneider Electric Bankability Flexible Higher Return on Investment Easy to Install Easy to Service Designed for Reliability 6

7 Conext RL Applications
> Residential Solar with Flat Roofs > Residential Solar with Partial Shading > Residential Solar with odd number of Modules > Residential Solar with Multiple Pitched Roofs > Residential Solar with Different Orientation Roofs (East-West)

8 Conext RL – A new Generation of Inverters
The Conext RL Series are tier 1, premium single phase grid-tie inverters from the global specialist in energy management, Schneider Electric Characterized by their reliability, performance and durability The Conext RL inverters feature high conversion efficiency, low start up voltage, wide MPPT window and shade tolerant algorithm which translates to higher energy yield, superior performance and higher return on investment The Conext RL inverters operate across a wider temperature and humidity range and are ideal for Australian conditions Available as 3kVA (3kW), 4kVA (4kW) and 5kVA (4.95kW) power ratings 8

9 Best in Class Power to Weight Ratio
Highest power to weight ratio compared with the two leading brands in the market Conext RL inverters feature superior thermal performance with fanless operation A lighter inverter is easier to handle and takes less time to install Power to Weight Ratio watts / kg * Comparison of Conext RL 5000E against other two leading inverters in the market 9

10 Best in Class Operating Temperature Range
Conext RL inverters operate from -20 to +65 degrees centigrade and is a better match for Australian conditions Conext’s temperature derating is competitive and most cases superior across the entire product range Maximum Operating Temperature Operating Temperature 0C * Comparison of Conext RL 5000E against other two leading inverters in the market 10

11 Best in Class Power Conversion Efficiency
Conext RL Inverters feature a European Efficiency > 0.5% higher than the other two leading brands in the market Conext RL peak efficiency is also highest in its class at 97.5% A higher efficiency means greater energy yield from the same number PV solar modules European Efficiency Efficiency % “More than half of all respondents would pay at least a % premium for a 1% efficiency gain” – IMS Research, Global survey of 350+ distributors, wholesalers, installers, integrators and EPCs, Dec 2011 * Comparison of Conext RL 5000E against other two leading inverters in the market 11

12 Best in Class Operating Window
Conext RL 5000E inverter features a start up voltage of 90VDC, this means the inverter starts to operate earlier in the day and turns off latter in the evening A low start up voltage means higher energy yield as inverter starts to operate at lower light levels compared with competitive products Voltage Operating Window Voltage V * Comparison of Conext RL 5000E against other two leading inverters in the market 12

13 Best in Class Cost Competiveness
Conext RL Inverters represent are competitively priced ($/ watt) against the other tier 1 inverter brands in the market A high energy yield and low cost results in a more attractive payback and ROI Relative Cost per Watt, $ / W Relative Cost Schneider Electric Brand A Brand B Relative costs based on survey by Schneider Electric (Jan 2014) comparing three leading brands in market at installer cost level * Comparison of Conext RL 5000E against other two leading inverters in the market 13

14 Conext RL vs Brands A & B Tier 1 Competitors
Brand A Brand B Note: MPPT includes no. of MPPTs and MPPT voltage range; ambient conditions includes IP rating and operating temperature range; Ease of handling includes W/kg and W/dm3; Analysis for a representative 3kW inverter

15 Agenda 1 Schneider Electric’s Bankability 2 Why Conext RL Inverters 3
Conext Designed for Performance 4 Connectivity and Communications 5 Service, Support and Warranty Explain sections – and how long we will speak on each topic. Want people to ask questions during the presentation. I will try to answer them. If I can’t I will get back to you.

16 Conext Mechanical Feature Set
16

17 Conext Mechanical Feature Set
Natural cooling, fan-less operation, with a wide operating temperature range from -20oC to +65oC. IP65 environmental rating from dust and water ingression, suitable for indoor or outdoor installation Removable, AC connector rated at IP67 Genuine MC4 connectors for DC solar connections White powdered coated aluminum enclosure for heat reflection, durability, high strength and low weight Fast and simple to install, mounting bracket included 17

18 Conext Designed for Performance
Wide Grid Voltage Operation Operates with Unbalanced Arrays Low Voltage Ride Through Conext Designer Software Shade Tolerant Algorithm

19 Shade Tolerant MPPT Algorithm
An ability to harvest the maximum amount of energy from a PV array is one of the small number of critical features a PV inverter can offer to optimise return on a PV system investment (ROI) Partially shaded arrays can introduce significant challenges when optimising harvest energy Energy harvest is maximized at the V-I point of inflection, for traditional MPPT trackers this coincides at the local maxima at the highest array voltage 19

20 Shade Tolerant MPPT Algorithm
Schneider Electric’s Shade-Tolerant Fast SweepTM MPPT Algorithm harvests maximum possible power at “Global Maximum,” unlike Traditional MPPT algorithms that track “Localized Power Bump” The Shade Tolerate Algorithm for string inverters can even result in higher energy yield than micro inverters in many common situations of shade.* * White Paper – Photovoltaic String Inverters and Shade- Tolerant Maximum Power point Tracking: Toward Optimal Harvest Efficiency and Maximum ROI, by Dr Andrew Swingler, © 2010 Schneider Electric 20

21 Conext Supports Flexible Solar Array Configurations
Comments Power Output Number of Panels > 12 Exceeds Voc > 550VDC at low temperatures 9 to 11 Very good design – operates within MPPT window across whole temperature range 4.5 to 5.5 kW 7 to 8 Good design – operates within MPPT window across whole temperature range at slightly less yield (< 1%) 3.5 to 4.0 kW 4 to 6 Warning – operates outside MPPT at high ambient temperature but still within operating range of inverter 2.0 to 3.0 kW < 3 Outside operating range of inverter will not start Array 2 Conext RL 5000E Calculated using a ET Solar 250W poly solar module, operated over -10 to +65oC ambient temperature 21

22 String 1: 12 modules 2820W STC, String 2: 7 modules 1645W STC
Supports Installations with Unbalanced Arrays Applications 2 Independent Strings String 1: 12 modules 2820W STC, String 2: 7 modules 1645W STC 600 Vdc 200 500 400 300 100 550 Yingli P235 (235 W) 1 x 12 Array 1 1 x 7 Array 2 Power (W) 2820 1645 Maximum Voltage at Cold Conditions 533 311 Minimum Voltage at Hot Conditions 283 165 Residential solar with odd number of modules Residential solar with multiple pitched roofs Conext RL 4000E Notes: Assumed Voc in cold conditions is 120% of Voc at STC Assumed Vmpp in hot conditions is 80% of Vmpp at STC 22

23 Wide Operating Voltage Maximizes Energy Harvest
Conext RL’s broad operating voltage range extends your solar day – additional yield early morning and late afternoon Operating Voltage Range of Conext RL 3000E DC voltage (V) at each MPPT channel 3.0 kW 1.7 kW 90V V V 500V V 550V Output power (W) 1.0 kW 23

24 with different orientation roofs (East-West)
Supports Arrays on Roofs with Different Orientations Due to the different orientations, the East and West facing solar modules are exposed to different irradiation levels throughout the day As a result their PV outputs are different throughout the day This leads to array mismatching and sub-optimal PV system performance Conext RL dual MPPT inverter is the right choice to handle such scenario Residential solar with different orientation roofs (East-West) 24

25 Derating of output power due to grid voltage
Wide Voltage Operating Window Conext RL Inverters Derating of output power due to grid voltage Conext RL Inverters operate at full rated power output when the grid voltage varies from 216 to 276Vac Conext RL operate at a reduced output from 216 to 184Vac A wide voltage operating window means the Conext inverter is producing energy with even with large variations in grid voltage Operating Voltage Range of Conext RL 5000E 4.95 kW 4.3 kW 184V V V Output power (W) AC Mains Input Voltage 25

26 Derating of output power due to grid voltage
Low Voltage Ride Through Conext RL Inverters Derating of output power due to grid voltage Low Voltage Ride Through (LVRT) is also known as Fault Ride Through (FRT) and refers to a feature that keeps the inverter online during short duration voltage dips to help support the grid The value U1 can be as low as 20% of Unonimal input at a duration of 200mSec Default settings t1 = 0.2, t2 = 0.4 & t3 = 0.4 secs U2 = 85%, U1 = 20% of Unominal Presently not able to change these settings through the software U grid / U nominal 100% 1 U2 2 U1 3 t1 = 0.2s t2 = t3 = 0.4s Time (secs) 26

27 Conext Designer Software
Conext Designer Software – free download from Schneider Electric Solar Website, compatible with Windows and Mac OS Helps to simplify and expedite the configuration of the solar PV plant Extensive library of PV Solar Modules, with ability to add user defined PV Solar Modules Program allows user to optimize Solar PV Solution for maximum performance estimated yield User adjustable parameters; temperature range, inclination, azimuth 27

28 Conext Designer – Project Design
28

29 Conext Designer – Plant Design
29

30 Conext Designer – Results Summary
30

31 Agenda 1 Schneider Electric’s Bankability 2 Why Conext RL Inverters 3
Conext Designed for Performance 4 Connectivity and Communications 5 Service, Support and Warranty Explain sections – and how long we will speak on each topic. Want people to ask questions during the presentation. I will try to answer them. If I can’t I will get back to you.

32 Conext Connectivity & Communications
ModBus Communications (open standard) interface as standard Optional Ethernet Interface with embedded Webpage available, that can be viewed of any smart device (tablet, smart phone, PC, smart TV etc..) Programmable digital output (N.O. / N.C.) contacts Conext RL Inverters supported and integrated through to third party applications such as MeteoControl, SolarLog, StuctureWare, SCADA and EGX300 products Local or remote monitoring options 32

33 Conext RL Local Monitoring
Hardwired Wireless 33

34 Conext RL Ethernet Card
Fast and easy to install and configure Web pages accessible through built in web server Monitor basic PV plant performance from inside the home Fully flexible operation – login as Owner, Installer or Engineer, password protected levels Supports multiple languages Events log to assist troubleshooting Ethernet Card 34

35 Dashboard – Monitor PV Plant Performance
35

36 Conext RL Remote Monitoring
36

37 Conext RL Conext Monitor 20
Compact, low cost monitoring and control unit Suitable for PV systems up to 3 inverters or 20kW Easy to configure and use Monitor PV plant performance using a web portal Remote active power control possible Multi language support Real time and historical data Conext Monitor 20 37

38 Dashboard – Monitor PV Plant Performance
38

39 Agenda 1 Schneider Electric’s Bankability 2 Why Conext RL Inverters 3
Conext Designed for Performance 4 Connectivity and Communications 5 Service, Support and Warranty Explain sections – and how long we will speak on each topic. Want people to ask questions during the presentation. I will try to answer them. If I can’t I will get back to you.

40 Designed for Reliability
Schneider Electric Solar PV inverters undergo Multiple Environmental Over Stress Testing (MEOST) to identify weaknesses in order to make improvements Conext RL is tested above its specified operating range of -20oC to +65oC Unit is operated from -40oC to +90oC for determination of reliability margin Unit is tested to check if it can withstand consecutive rapid thermal transitions Improvements are made on the design based on findings at cold / hot temperature & vibration Types of Reliability Testing: THB: Temperature humidity bias Salt-Fog testing HALT: Highly accelerated life test MEOST: Multiple Environmental over stress testing Custom reliability testing Extreme Weather Conditions -30C to +100C Vibration Input / Output Usage Profiles VDC / VAC Combined Stresses

41 Training and Technical Support
Australia wide training for the Conext RL products and listed with the Clean Energy Council and attracting 40 CPD points Technical support from 8.00am to 5.30pm Monday to Friday on (Central Time) Level 1, 2 and 3 technical support

42 Warranty Support Field or in store replacement service
Australian based test and repair service available for out of warranty equipment Factory trained and certified technicians

43 Summary: Conext RL is Flexible and Efficient Residential Solar Solution
High Energy Harvest Low Cost of Installation and Maintenance Protection of the Value of your Asset Schneider Electric Bankability Easy to Install Flexible Easy to Service Designed for Reliability Minimizes Total Cost of Ownership 43


Download ppt "Conext RL 3, 4 and 5kVA Grid Tie Inverters Designed for Flexible and Efficient Residential Solar Solutions v3.0."