1 PowerShield Battery Monitoring Systems protecting your power supply

2 PowerShield - Data Center Solutions
Permanent monitoring solution designed for stand-by batteries Complete package including hardware & software Designed to allow IEEE/IEC best practice Fast, accurate, safe & smart Visibility of your battery assets Be in control of your batteries. P r o t e c t i n g y o u r p o w e r s u p p l y

3 P r o t e c t i n g y o u r p o w e r s u p p l y
In the Battery Room Modular layout for safety, efficiency, scalability - Sentinel controller + m-Senzor battery sensors Up to 1280 blocks / 16 strings per hardware system Stand-alone system operation with on-board memory Can operate without PC or external comms UL, CUL, CE, C-Tick, FCC, KCC certified Fast & tidy installation Battery & UPS brand neutral Maintain manufacturer flexibility & capability for future expansion P r o t e c t i n g y o u r p o w e r s u p p l y

4 P r o t e c t i n g y o u r p o w e r s u p p l y
In the Battery Room All parameters sampled continuously & automatically Rapid identification of catastrophic failures Automatic data logging Allows historic & predictive trending over battery lifetime Automatic data logging of battery discharge Live assessment of performance Capacity analysis UPS self-test & intermittent charging compatibility Make best use of UPS functionality All events and alarms time & date stamped P r o t e c t i n g y o u r p o w e r s u p p l y

5 P r o t e c t i n g y o u r p o w e r s u p p l y
At the Battery Individual block voltage, sampled simultaneously every 4 seconds True real-time visibility Individual block impedance, sampled daily Sampled only in Float for best comparison & life trending Internal high precision reference for self-calibration Individual block temperature option Measured at negative terminal as per IEEE recommendations Accurate & block specific thermal runaway detection P r o t e c t i n g y o u r p o w e r s u p p l y

6 P r o t e c t i n g y o u r p o w e r s u p p l y
At the Battery 750VDC optical isolation at battery Increased safety of personnel & facility Install flexibility & efficiency – consolidate different block & string voltages [UPS, 48V, genset, emergency lighting] Factory terminated cable sets with no fusing required Intelligence at the battery Ripple & noise rejection Self-protection Bi-colour LED for fast identification No more manual battery testing. P r o t e c t i n g y o u r p o w e r s u p p l y

7 P r o t e c t i n g y o u r p o w e r s u p p l y
Raising the Alarm Alarms for block voltage, impedance & temperature [thermal runaway]; string voltage & current; ambient temperature All alarm settings user-editable, but with initial defaults offered Self-learnt automatic baseline for impedance All alarm settings are battery & application specific Detailed, specific alarm information – to individual block level System intelligence applies appropriate limit set for battery state – Float/Charge/Discharge/Idle Notification of change of string state Alarms for internal system diagnostics P r o t e c t i n g y o u r p o w e r s u p p l y

8 P r o t e c t i n g y o u r p o w e r s u p p l y
In the Control Room Alarm & data options for data center integration: Ethernet to PowerShield Link software Allows review at all levels – control room, facility managers, service providers, equipment suppliers. Both life trend and discharge event data presented Battery data stays under your control & ownership ModbusRTU/TCP or SNMP to local building management system Integrate with existing facility systems Allows implementation of multiple alarm sets Dry contacts for additional alarm outputs or actions Dedicated serial port for local service & diagnostics High visibility & ownership of your battery assets. P r o t e c t i n g y o u r p o w e r s u p p l y

9 Accessing Your Battery Data
P r o t e c t i n g y o u r p o w e r s u p p l y

10 PowerShield Link Software
New Dashboard screen for Link – see all the batteries in your facility at a single screen. Fast overview Onscreen alarm pop-ups Single click for site report Simple colour coded buttons Drill down to battery specific detail & alarms Multi-seat, multi-user P r o t e c t i n g y o u r p o w e r s u p p l y

11 PowerShield Link Software
Permanent connection to multiple sites – unlimited total number of batteries Real time battery status, including discharge Remote access via LAN Alarm & activity log alarm alerts Battery database for life trending Graphing & analysis tools Automated data management Battery management is more than just waiting for alarms P r o t e c t i n g y o u r p o w e r s u p p l y

12 PowerShield Link Software
Comprehensive user report set Preformatted PDF or Raw CSV data Facility summary Discharge – individual events in detail, activity summary Trending – Impedance change, end-of-life, charge voltage, temperature Alarm history, fault tracking, service log Warranty claim support documentation Reports suitable for management & service teams Independent remote Reporting Service available P r o t e c t i n g y o u r p o w e r s u p p l y

13 P r o t e c t i n g y o u r p o w e r s u p p l y
PowerShield Users Equinix – Hong Kong, Singapore, Australia, New Zealand HP – Austin TX, Australia IBM – Australia, New Zealand, UK, South Africa, France Bank of America – UK, Hong Kong, Singapore, Australia Microsoft - Ireland Huawei - China Bloomberg - global Barclays Bank – UK "PowerShield gives us the confidence to get on with running our business with the peace of mind that, should there be a power outage, our backup battery is in A1 condition."  - Television New Zealand P r o t e c t i n g y o u r p o w e r s u p p l y

14 P r o t e c t i n g y o u r p o w e r s u p p l y
PowerShield Ltd Developing battery monitoring solutions since 1996 In-house hardware & software teams Strong R&D team with continuous product development and battery research Independent of battery & UPS suppliers CTO is working group member of the IEEE Stationary Battery Committee. Current Vice Chair of IEEE 1491 Guide for Selection and Use of Battery Monitoring Equipment in Stationary Applications. P r o t e c t i n g y o u r p o w e r s u p p l y

15 P r o t e c t i n g y o u r p o w e r s u p p l y
PowerShield Ltd Global reach, local focus PowerShield technical & reseller support in territory – USA, Singapore, UK Stock holdings – USA, Singapore, UK Factory trained installation partners globally - direct access to factory support if required P r o t e c t i n g y o u r p o w e r s u p p l y

16 Notes: What We Measure & Why
Individual block voltage – ensure correct charge and performance under load Individual block impedance – impedance change gives a solid life trend and end of life assessment. Ambient temperature at the cabinet/rack – high temperatures kill batteries. A 10°C increase gives a 50% decrease in life expectancy String current – allows detection of unbalanced strings, and provides rapid understanding of battery activity String voltage – confirmation of UPS operation & compliance with battery specification Individual block temperature [optional] – better knowledge of temperature gradients in cabinets; pre-empt thermal runaway P r o t e c t i n g y o u r p o w e r s u p p l y

17 Looking After Your Batteries
A 10°C increase gives a 50% decrease in life expectancy P r o t e c t i n g y o u r p o w e r s u p p l y

18 Looking After Your Batteries
Incorrect float voltage significantly affects life expectancy P r o t e c t i n g y o u r p o w e r s u p p l y