Download presentation
Presentation is loading. Please wait.
Published byJimmy Wyand Modified over 10 years ago
1
Preferred Utilities Manufacturing Corporation
2
q Introduction q Architecture q Communication Networks q Operation Workstation q Summary Preferred Utilities Manufacturing Corp.
3
Founded in 1920 and in continuous operation since then. We are an engineering - based manufacturer of combustion and fuel handling products for industrial, institutional, and commercial power plants. Our Core Business is Combustion Control. Preferred Utilities Manufacturing Corp.
4
Sales representative organizations supported by Regional Managers cover all major markets throughout the United States. Headquarters Danbury, CT Preferred Utilities Manufacturing Corp.
5
Pre-wired Combustion Control/ Flame Safeguard Control Cabinet SCADA/Flex System Integrated Flame Scanner and Oxygen Analyzer! Single Boiler Remote Control
6
Simple Local Control with Expanded View Remote Control Two Controllers shown as Five (5) Faceplates
7
Multiple Equipment Control System
8
Intuitive Remote Control
10
q Multiple, physically separated, controller and/or I/O nodes q Controllers and I/O nodes may be located close to the process being controlled q Multiple remote operator workstations q Reliable, high speed communications network Distributed Control System: q Loop Controllers can be used as backup control station if the workstation, or communication network breaks down
11
Local Control Network (Modbus) PCC-III Controllers Redundant Workstations Distributed Control System:
12
Distributed Communication Network RS-485 Modbus…. q High Speed: 1200-38,400 baud q Mode: ASCII or RTU q Medium: 3 wire shielded cable, up to 4000 ft in length q RS232/RS485 Converters: Used to interface to SCADA workstation communication ports
13
Typical Communication Network Slower Comm. Speed BMS Equipment Networked On A Separate Highway
14
Input / Output Flexible…. Supporting over 7,000 words of I/O Data Some Typically Networked Items: Allen Bradley Data Highway Allen Bradley SLC 500 Cleaver Brooks Hawk Fireye E300/E100 GE 90-30, 90-70 Honeywell 7700/7800
15
Remote Monitoring Flexible…. Dedicated Phone Line Control of Multiple Locations Alarm Pager: Monitors Alarms and events for any location
16
Operator Workstation Features…. q Intellution iFix q Centralized Boiler Control q Data Acquisition q Alarm Monitoring q Historical Trending q Boiler Tuning q Reports
17
Smart, Central Boiler Control
20
Alarm Management
21
Smart, Central Boiler Control
23
Data Acquisition
25
Historical Trending
27
Boiler Tuning
28
Meaningful Reports q Total steam generated by the plant and each boiler q Total fuel used by the plant and each boiler q Average cost of steam q Efficiency of the plant and each boiler q Heating degree days for the reporting period q Make-up water flow in pounds and also as a percent of steam flow q Hours of operation for each boiler q Steam flow to each of the distribution headers q All reported for the shift, day, month, and year day, or shift depending on the report being generated.
29
Meaningful Reports
30
Preferreds DCS Summary SCADA/Flex is a…. 4 Distributed Control System with Loop Controller local control security 4 Integrated controls system, compatible with other systems and control components 4 Incorporates a Boiler Room Focus and Experience
31
Preferred Utilities Manufacturing Corp For further information, contact... Preferred Utilities Manufacturing Corporation 31-35 South St. Danbury CT T: (203) 743-6741 F: (203) 798-7313 www.preferred-mfg.com