A Novel Device for Plating Process Diagnostics
‘L-Cell’ A Novel Device for Plating Process Diagnostics L-Chem, Inc. Shaker Heights, OH 44120
2
Introducing a novel, multi-purpose device that provides:
Process parameters Process diagnostics Fully automated No expertise required Fast (2 min./test)
3
OUTLINE Rationalle and need Current tecnology and its defficiencies
The L-Cell - principles and description Examples Conclusions
4
Issues in Plating Predictive Design Meeting Specs., Optimization
Process Control and Maintenance Environmental and Health New Materials
5
} L-Cell Available Tools FUTURE: PAST: Predictive Design
Optimization Process Control } Computer Aided Design Software - ‘Cell-Design’ PAST: L-Cell FUTURE: Hull-Cell Electroanalytical Techniques- Polarization studies Conductivity Titration (reactant conc.)
6
Limitations of CAD Software
INPUT Cell configuration Cell Anodes Racks and Shields OUTPUT Current distribution Deposit thickness distribution Potential distribution Overpotential (polarization) Parasitic reaction rates Alloy composition Part’s evolving shape Deposit texture Operating Conditions current or voltage (DC or Periodic) temperature flow Numerical ‘Solver’ Process Properties Electrode polarization Electrolyte conductivity Diffusivity Often Missing
7
Issues with Obtaining Process Data using Conventional Approach
Strong dependence on trace additives Proprietary formulations Lack of fundamental mechanistic understanding Laboratory experiments often do not duplicate process conditions Flow dependence Cost: Potentiostat ~ $ 20, ,000 Rotating disk electrode ~ $ 10,000 PhD investigator ~ $ 100K/yr i V
8
Limitations of the Hull-Cell
Qualitative Current distribution is inherently inaccurate – varies with material No quantitative data
9
The L-Cell Provides: Comprehensive electrochemical process parameters
Polarization curves Kinetics parameters Conductivity Process diagnostics: Indication of process variation due to additives consumption contamination Tool for process adjustment using a small (50 ml) volume Sample plated at a number of different and precisely known current densities for visual and analytical off-line testing Composition of alloy – partial currents Thickness measurements – current efficiency as f(i) Fully automated, fast (2 min.) experiment designed for non-experts Equipment is relatively inexpensive
10
THE L-Cell – Principle of Operation
Multi-electrode cartridge and a cell that allows a separate current feed to each segment Electronics to provide a different and precisely measured current density to each segment Automated data acquisition and analysis Plated cartridge with segmented electrodes Cross-section
11
The L-Cell: Table-top design
12
The multi-pin connector
13
The L-Cell: Table-top design
14
The L-Cell: Table-top design
Watts Nickel Testing
15
Design of the L-Cell ‘Cell-Design’ Modeling Top View (cross-section):
Anode: oxygen evolution Segmented cathode (plated cartridge) Current distribution – different between segments but uniform on each segment Potential distribution: Reference electrode
16
THE L-Cell – Analytical Approach
Unknowns: Cathodic polarization curve: iK =f (hA) Cathodic overpotentials (i0, aC, aA) Conductivity Measure: Segmental current densities Voltages (including reference electrodes) Conductivity Voltage balances Across the cell Overpotentials Data analysis Butler-Volmer fit kinetics parameters (i0, aC, aA)
17
DATA ANALYSIS Butler-Volmer: Mass transport included: CE = CB CB CE
(pure kinetics, No transport limitations) CE = CB Mass transport included: CB CE Here, i0 is measured at CB and:
18
DATA ANALYSIS Tafel approximation:
Equivalent mass transport boundary layer thickness
19
DATA ANALYSIS ik = Equivalent pure ‘kinetics‘ current derived from the measured current density, i
20
The L-Cell System
21
DATA AQUISITION 0.18 1.25 1.09 29.0 18.1 14.2 8.3 5.0 22. 6 3.02
22
Cu deposition Copper sulfate 0.5 M pH=2 Polarization curve
Kinetics Parameters
23
Cu deposition Copper sulfate 0.5 M pH=2 100 ppm PEG
24
Comparing two tests Cu deposition Copper sulfate 0.5 M pH=2
Compare with: 100 ppm PEG Pure Cu w/PEG
25
Specification of acceptable deviation
w/PEG
26
Copper deposition from copper sulfate No additives; pH=2
27
Copper deposition from copper sulfate pH=2
No PEG 100 ppm PEG Log i [mA/cm2]
28
Nickel Deposition from a standard Nickel Watts Electrolyte
Overpotential, η [V]
29
Nickel Deposition from a standard Nickel Watts Electrolyte
Overpotential, η [V]
30
Wagner Number
31
Throwing Power
32
Summary - The L-Cell Provides:
Process properties: Polarization, Kinetics, Conductivity Use ‘regular production’ solution By-pass specialized testing – no special expertise needed No need to scan v-i, or apply transients – use steady-state data Fast (2 min.), completely automated Produces deposit samples plated at different current densities Process diagnostics tool