Cyprus Pump Test
2
Cyprus
5
Aquifer Study Area
6
Yeşilkoy Aquifer Area Recharge Area Discharge Area Water Levels in Local Wells 2002 - 2006 2 m drop 5 m drop
7
Yesilkoy Geology Calcarenite in the Yeşilkoy aquifer Hydraulic Conductivity of Calcarenite
8
Yesilkoy Aquifer Initial Conceptual Model (Unconfined aquifer)
9
Yesilkoy Pump Test
10
Pumping Well
11
Observation Well
12
Pump Test Results Hand measured Drawdown and Recovery for YK-109 Transducer measured Data for Drawdown and Recovery of YK-109
13
Pump Test Analysis YK-109 Drawdown Analysis using Theis Method in AquiferTest
15
Match Point 1/u = 10, W(u) = 1.0 t = 150 min, s = 11 cm
16
Theis Method Example Match Point 1/u = 10, W(u) = 1.0 t = 150 min, s = 11 cm Q = 0.4359 m3/min
18
Yeşilköy Aquifer Updated Conceptual Model (Leaky confined aquifer)