1
Splash
2
TB8100 BASE STATION TA2444-01 Change Over Module
3
Change Over Module Provides automated failure protection for TB8100
If the master channel fails, the antennas and User Interface are switched over to the standby channel Solution is an equivalnet to the T800 + TA703 Changeover Module, but vastly more flexible. Uses Task Manager and an Applications PCB Operation can be customised by modifying supplied Task Manager template file (QA2444A8X) Can be fitted to either a single or dual channel rack frame
4
Change Over Module Alarms can be allocated to two priority groupings, ‘high’ and ‘low’, ensures best channel is always selected. Eg. Slave channel is active channel Master channel has low priority alarm. If Slave channel detects high prioirty alarm, system will change-over back to the to Master channel as it’s alarm has a lower priority. Default change over timings setup for ~5 seconds. Optional external power sensors can be used to measure power levels at the antenna. Receiver input is monitored by comparing RSSI levels and gate outputs from both channels. A shared heart beat ensures the idle channel will seize control if active channel fails completely. The same Task Manager template files are used in BOTH channels.
5
Change Over Module Also refer to:
TA Change-over Module Operation and Service Manual. (M ) Requires either: 25 way isolated SIF 25 way E&M SIF
6
Change Over Module
7
Lets take a look at the programming software...
8
Splash