NAF Product Training
2
NAF-eValuate
3
NAF-eValuateTM What is NAF-eValuate?
FDT-based software package for configuration and diagnostics Includes: PACTwareTM software cd PACTwareTM user manual NAF-eValuate Quick guide NAF-LinkIT DTMs
4
FDT / DTM NAF-LinkIT fully integrated with FDT / DTM
5
FDT / DTM What is FDT? FDT is a standardised software interface description FDT defines the co-operation between drivers (DTMs) and a FDT container PACTware is a FDT frame FDT container DTM
6
FDT / DTM What is a DTM? A DTM (Device Type Manager) is a driver for
instruments components communication interfaces A DTM includes all instrument-specific data and functions all graphic elements and dialogues for adjustment A DTM is no independently executable software HART
7
FDT / DTM PACTware frame Process Automation Configuration Tool
Device Type Manager (DTM) Field Device Tool (FDT) Container HART
8
FDT / DTM PACTware frame
The Device Type Manager plugs into any FDT Compliant Frame like PACTware Manufacturer-independent: One tool for all instruments
9
FDT / DTM System integration One DTM for all FDT systems
Same functionality in all systems Industrial IT FieldCare or with any other FTD frame application
10
FDT / DTM NAF-LinkIT : Overview
11
FDT / DTM NAF-LinkIT : Parameter (Identifier)
12
FDT / DTM NAF-LinkIT : Parameter (Parameter)
13
FDT / DTM NAF-LinkIT : Parameter (Configuration)
14
FDT / DTM NAF-LinkIT : Parameter (Characterization) Features
Custom defined Characteristic line with up to 22 points Linear Quick open Equal percentage
15
FDT / DTM NAF-LinkIT : Parameter (Travel) Features
Configurable travel stop Cut-off function
16
FDT / DTM NAF-LinkIT : Parameter (Alarms) Features
Freely defined alarm limits
17
FDT / DTM NAF-LinkIT : Parameter (Tuning) Features
Individual setting of P and I parameters for increasing and decreasing movement
18
FDT / DTM NAF-LinkIT : Parameter (Options) Features
Easy start up of options
19
FDT / DTM NAF-LinkIT : Parameter (Maintenance) Features
Configuration of 4 independent Historian from 15 Minutes, hours, days up to 60 Months (5 Years) Configuration of Service Reminder in x Hours
20
FDT / DTM NAF-LinkIT : Parameter (Partial stroke test) Features
Intelligent valve solutions for safety systems and Emergency Shutdown (ESD) applications On-line testing and diagnosis Manual or Automatic activation of the test Freely definable stroke range
21
FDT / DTM NAF-LinkIT : Parameter (LCD) Features
Possible to turn the LCD text 180° The LCD text is available in 3 language where the 3e language is exchangeable
22
FDT / DTM NAF-LinkIT : Measured Values (Measurement) Features
Show measurement like Setpoint, Control deviation, valve position etc,
23
FDT / DTM NAF-LinkIT : Measured values (Trend Viewer) Features
Trend Viewer shows Setpoint Stem position Valve position Control deviation Output 1 Output 2 The scale could easily be changed with the mouse pointer (time and value)
24
FDT / DTM NAF-LinkIT : Diagnostics (Status Detail / Overview) Features
Easy overview show if the positioner is Ok or if there is an alarm
25
FDT / DTM NAF-LinkIT : Diagnostics (Status Detail / Process) Features
Measured Temperature Values as Drag-Pointers for Min.- and Max. Temperatures Temperature Alarms if the Temperature is below -40°C/°F or above 80°C/176°F Power Supply Alarms for Low and High Power
26
FDT / DTM NAF-LinkIT : Diagnostics (Status Detail / Hardware) Features
Information about fail in hardware like Electronic Components Internal Electronic Interfaces External Electronic Interfaces Mechanical Interfaces
27
FDT / DTM NAF-LinkIT : Diagnostic (Status Detail / Calibration)
Features No Autostart done Configuration
28
FDT / DTM NAF-LinkIT : Diagnostic (Status Detail / Position Alarms)
Features Show Historical and Current alarms
29
FDT / DTM NAF-LinkIT : Diagnostic (Status Detail / Service Management)
Features Displays the status for the operator if the valve needs to be serviced or if the valve is GOOD Display of total non-resetable operation time in hours Display of operation time since last service Display of Service Reminder, when the operator shall be informed about the next service Cycle Counter and Travel Sum
30
FDT / DTM NAF-LinkIT : Diagnostic (Status Detail / Position History)
Features Position History to identify the valve position of valve/actuator over the time Position History can be differentiated from 15 Minutes up to 5 Years All data stored inside the positioner to allow later investigation in the workshop Historian available up to 5 years
31
FDT / DTM NAF-LinkIT : Position History - Evaluation
Over specified Valve Under specified Valve
32
FDT / DTM NAF-LinkIT : Diagnostic (Status Detail / Service Management)
Features 5 different Response Status are detected and displayed Offline Steady Transient Offset Unstable Response History can de differentiated from 15 Minutes up to 5 Years All data stored inside the positioner to allow later investigation in the workshop Historian available up to 5 years
33
FDT / DTM NAF-LinkIT : Diagnostic (Status Detail / Service Management)
Evaluation over the last 15 Minutes 1% of its time the valve has been „Offline“ 81% of its time the valve was in a „Steady“ state 13 % of its time the valve was „Transient“ = moving 4% of its time the valve was „Offset“ = remaining Control deviation 1% of its time the valve-position was oscillating around the set point and caused the valve to be „Unstable“
34
FDT / DTM NAF-LinkIT : Trend Viewer – Indication of Unstable control behaviour Features Indication of leakage in piping between positioner and actuator Leakage in actuator piston
35
FDT / DTM NAF-LinkIT : Diagnostics (Status List) Features
“RED” Failure “YELLOW” Maintenance required “GREEN” Ok “GREY” Information
36
FDT / DTM NAF-LinkIT : Additional Functions