Vacuum status at KEKB Junji Haba
2
KEKB Vacuum system
3
Vacuum monitoring
4
HER vacuum characteristics
Dependence on HER current is clear. <p> ~ 0.3 (0A) 1.2 (1.3A) x10-7Pa 1nTorr (PEPII) =1.3 x 10-7 Pa (KEKB) Far from “base pressure dominance” Not always simple linear relation Some show a clear thermal behavior Beam life time is a function not only of pressure but also luminosity or beam-beam effect.
5
2004 June
6
Heat up at the feed back kicker structure Discharge starts around 0.9A at septum?
8
Life time is predetermined by luminosity
9
Beam-beam also affects the lifetime
LER current HER beam size vs LER current HER life and beam size
10
LER vacuum characteristics
Current dependence is clear <p>~ 0.2 (0A) 0.8 (1.6A) x10-7Pa Thermal behavior everywhere we have the parts with a special internal shape like GV, crotches, injection chamber etc.