Presentation is loading. Please wait.

Presentation is loading. Please wait.

SCM2100-V Series:Precision Vacuum Measurement

Similar presentations


Presentation on theme: "SCM2100-V Series:Precision Vacuum Measurement"— Presentation transcript:

1 SCM2100-V Series:Precision Vacuum Measurement
Vacuum Pressure Transmitter 4-20mA Loop output Tem-Tech Lab SCM2100-V Series:Precision Vacuum Measurement 4-20mA Loop(15VDC) output Isolated type (4-wire system) Disconnection Detect LED Applications ・Saffire™ vacuum sensor is designed to reduce the drift and ambient pressure sensitivity associated with metal diaphragm capacitive gauges ・The SCM2100-V is the perfect solution for controlling or monitoring process gases of any type in vacuum applications Features & Benefits Saffire™ stick sensor construction results in two sided naturally balanced  pressure measurement Small footprint allows for mounting near chamber or in thigh space Mounting orientation has no affect on sensor zero Crystalline sensor design results in a robust zero stability when exposed to high pressure 4-20mA loop (15VDC) output , disconnection detect function IP65 Auto zero function

2 SCM2100-V Series Tem-Tech Lab Dimensions(mm) Specifications
Model SCM2100-V Application Various type of Vacuum equipments, Process gas control and Measurement Full Scale Range 10, 100, 500, 1000 Torr (kPa range available) Burst Pressure 400kPa Accuracy (L.H.R.*1 ) ±0.075%FS Output 4-20mA Power Supply 20~28VDC(24VDC recommend) 0.2A Operating Temp. -5 to 40 ℃ Zero Temperature Coefficient ± 0.01%FS/℃ Span Temperature Coefficient Resolution 0.01%FS Responsive 100ms Materials Exposed To Gases SUS316L, Inconel®, Sapphire Fitting VCR ¼”, ½”(standard); KF-16, ICF-34(option) Electrical Connector OMRON XS2, DC 4wire Enclose IP65 Weight Approx 316g note: *1 Linearity, Hysteresis & Repeatability Ordering Information (*SCM2100-V12T-F1-x) Model - Output Vacuum Range Fitting Type & Size X SCM2100 V 4-20mA loop 11T  10 Torr F1 Female VCR 1/4” (Std.) 12T  100 Torr F2 Female VCR3/8” 52T  500 Torr F3 Female VCR 1/2” (Std.) 13T  1000 Torr K1 KF-16(NW16KF) K2 KF-25(NW25KF) C1 ICF-34,others Tem-Tech Lab Head Office Tsukishima, Chuo-ku Tokyo Japan TEL: FAX: Osaka Branch # Minamikawahori-chou, Tennoji, Osaka, Osaka Japan TEL: FAX: URL: Contact : Specifications are subject to change without notice. AGENT: 1St Edition:Issued in Japan in 2013 No part of this publication may be reproduced or duplicated without the prior written permission of Tem-Tech Lab


Download ppt "SCM2100-V Series:Precision Vacuum Measurement"

Similar presentations


Ads by Google