Laboratory: A Typical Lithography Process
2
- Place the wafer in a tin plate.
3
- To make sure that the wafer is completely dry, place the tin plate containing the wafer into the dehydration oven for 30 minutes to "Pre-Bake" it.
4
- Using teflon tweezers, place the wafer on the wafer chuck in the center of the Photoresist Spinner.
5
- Using a Nitrogen Gun, blow the wafer surface to remove any dust particles.
6
- Using an eye dropper, flood the wafer surface with primer to facilitate resist adhesion to substrate.
7
- Press the spin button which will cause the wafer to spin at ~ 5000 rpm. Centrifugal force will cause excess primer to move away from the center until all wafer is primed and ready to accept resist. Then release spin button.
8
- No photos could be taken while resist is applied since it is sensitive to light. Actually all lighting in the clean room is covered by yellow filters.
9
- Give the resist a soft-bake in an oven at temperatures between 90 and 120 °C to semi-harden the resist. Meanwhile setup the mask aligner.
10
- For each layer there is a separate mask (patterned glass).
11
- Place the mask in the wafer holder so that the emulsion side of the mask is facing downward toward the wafer.
12
- Slide the wafer holder into the mask aligner.
13
- Tighten the two knobs to secure the wafer holder in place.
14
- Bring the resist-covered wafer back from the soft-bake oven.
15
- Carefully place the wafer on the wafer chuck of the aligner.
16
- Carefully slide the wafer chuck into the aligner so that the wafer is positioned under the mask.
17
- Slowly raise the lever so that the wafer comes into contact with the mask Then press the button marked “Separation” that will cause the wafer ~ 0.5 mm away from the mask without being scratched..
18
- Adjust the microscope knobs as well as knobs (three) that allow you to move the wafer in horizontal and vertical directions.
19
- Press expose button. A very bright light will come on inside the aligner. The exposure time is set according to the type of resist (~10 s)
20
- The type of developer solution used is determined by the type of resist chosen.
21
- Carefully place the wafer into a chemically resistant carrier.
22
- Be sure to lock the wafer so that it is firmly secured.
23
- Immerse the wafer in the developer for the recommended time ( ~ 30 s).
24
- Immediately after plunge the wafer into the beaker filled with water to stop the development process.
25
- Use a de-ionized water gun to completely clean the wafer.
26
- Use nitrogen gun to thoroughly dry the wafer, front and back.
27
- Inspect the wafer under the microscope to see if the patterns are clear and well defined.
28
- If everything is OK , place the wafer in the hard-bake oven which should be preheated to the required temperature ( °C).