Laboratory: A Typical Evaporation Process
2
- Open evaporator.
3
- Remove wafer holder.
4
- This is where the wafers will be during the evaporation process.
5
- Remove the bell jar.
6
- Prepare metal: e. g., use metal wire.
7
- The metal will be placed in a "basket".
8
- Some evaporators use a "coil" instead of a "basket".
9
- Both metal and basket/coil should be cleaned.
10
- They should then be dried in the dehydration oven.
11
- The basket/coil should be installed between the two electrodes,
and the metal placed inside the basket or around the coil.
12
- Move shutter to cover the filament.
13
- Put on the bell jar.
14
- Carefully load the wafers onto the wafer holder.
15
- One of the wafers may be a "test" wafer for measuring the metal layer thickness.
16
- Replace the wafer holder back on top of the bell jar.
17
- Place the cover back onto the bell jar.
18
- Lower pressure ( ~ 10-6 Torr ).
19
- Heat the filament to evaporate the metal.
20
- Cool and remove wafers.
21
- The test wafer allows measurement of film thickness.