Presentation is loading. Please wait.

Presentation is loading. Please wait.

Multicenter Nellix EndoVascular Aneurysm Sealing system experience in aneurysm sac sealing  Dittmar Böckler, MD, PhD, Andrew Holden, MBChB, Matt Thompson,

Similar presentations


Presentation on theme: "Multicenter Nellix EndoVascular Aneurysm Sealing system experience in aneurysm sac sealing  Dittmar Böckler, MD, PhD, Andrew Holden, MBChB, Matt Thompson,"— Presentation transcript:

1 Multicenter Nellix EndoVascular Aneurysm Sealing system experience in aneurysm sac sealing 
Dittmar Böckler, MD, PhD, Andrew Holden, MBChB, Matt Thompson, MD, Paul Hayes, MD, Dainis Krievins, MD, Jean-Paul P.M. de Vries, MD, PhD, Michel M.P.J. Reijnen, MD, PhD  Journal of Vascular Surgery  Volume 62, Issue 2, Pages (August 2015) DOI: /j.jvs Copyright © 2015 Society for Vascular Surgery Terms and Conditions

2 Fig 1 Schematic of Nellix devices after deployment.
Journal of Vascular Surgery  , DOI: ( /j.jvs ) Copyright © 2015 Society for Vascular Surgery Terms and Conditions

3 Fig 2 Schematic of cross section of Nellix devices within the aneurysm. Journal of Vascular Surgery  , DOI: ( /j.jvs ) Copyright © 2015 Society for Vascular Surgery Terms and Conditions

4 Fig 3 Nellix console with four ports and a close-up view of the in-line pressure transducer. Journal of Vascular Surgery  , DOI: ( /j.jvs ) Copyright © 2015 Society for Vascular Surgery Terms and Conditions

5 Fig 4 Kaplan-Meier curves of the composite end point, Nellix occlusion, reintervention, and type Ia endoleak. The composite end point was defined as the occurrence of type I or type III endoleak, sac enlargement >5 mm, death, aneurysm rupture, or aneurysm-related reintervention. Bars represent standard errors. Journal of Vascular Surgery  , DOI: ( /j.jvs ) Copyright © 2015 Society for Vascular Surgery Terms and Conditions

6 Fig 5 Contrast-enhanced computed tomography (CT) scan (axial view) demonstrates a type II endoleak in communication with lumbar arteries at 3 months (A) and 12 months (B) postoperatively. The aneurysm was 65 mm in diameter at baseline, and the blood lumen was small (34 mL). The aneurysm sac diameter remained unchanged through 1 year, with a slight increase in the size of the type II endoleak cavity. Journal of Vascular Surgery  , DOI: ( /j.jvs ) Copyright © 2015 Society for Vascular Surgery Terms and Conditions


Download ppt "Multicenter Nellix EndoVascular Aneurysm Sealing system experience in aneurysm sac sealing  Dittmar Böckler, MD, PhD, Andrew Holden, MBChB, Matt Thompson,"