LASER SYSTEM STATUS G.Gatti , A. Ghigo , C.Vicario , P.Musumeci ,
M. Petrarca , S. Cialdi , D. Filippetto REVIEW COMMITTEE 16/11/05
2
LASER SYSTEM STATUS OVERVIEW PULSE SHAPING Measurements & Calculations
SYSTEM PERFORMANCES Characterization PULSE SHAPING Measurements & Calculations UV TEMPORAL DIAGNOSTICS X-Correlator Streak Camera TIMING RF Synchronization & Jitter Measurement RF Power Triggering BEAM TRANSFER LINE Designed Set-up, Feedback
3
RF Reference R&S 2,856 GHz f/36 Pumps Seed Line Ext. Synch. Evolution
Nd:YLF Continuum Nd:Yag Verdi Nd:YVO4 Pumps 800 nm 10 nJ 80 MHz 100 fs Hidra CPA Ti:Sa Amplifier RGA + 2 MP Mira Ti:Sa Oscillator THG UV Stretcher Seed Line 800 nm 50 mJ 10 Hz 100 fs 266 nm 4 mJ 10 Hz 100 fs 266 nm 1,8 mJ 10 Hz ps DAZZLER TeO2 Synchro Lock PLL RF Reference R&S 2,856 GHz Ext. Synch. f/36
4
CHARACTERIZATION : OSCILLATOR
SPECTRUM GAUSSIAN SPECTRUM ∆λ=12nm FWHM PULSE LENGHT 130 fs FWHM 205 fs FWHM AUTOCORRELATION Single Shot AutoCorrelator
5
CHARACTERIZATION : AMPLIFIER
NEW IR TEMPORAL DIAGNOSTIC 400 fs STREAK-CAMERA TRANSVERSE INTENSITY TEM00 PULSE LENGHT 104 fs FWHM AUTOCORRELATION 2 DIFFERENT COMPRESSOR CONFIGURATIONS (CHIRP)
6
CHARACTERIZATION : UPCONVERSION
THG CRITICAL ELEMENT SLIGHTLY OUT OF SPECS 2 mJ REQUESTED 1.4mJ MEASURED NEW BBO BLUE SPECTRUM SH-BLUE 400 nm COMPROMISE BW/POWER UV SPECTRUM M2x: 2.7 M2y: 1.9 TH-UV 266 nm
7
STABILITY MEASUREMENTS
Out of Amplifier at 800 nm 2% Power Variations
8
PULSE SHAPING GOAL: 10ps Flat Top- 1ps rise time
Frequency Domain Filtering Through AO Device: DAZZLER EXPERIMENTAL SETUP -X-CORRELATOR NEW UV TEMPORAL DIAGNOSTIC READY -FIRST RESULTS OBTAINED IN FRASCATI X-CORRELATOR DIAGNOSTICS SPECTROM. SPECTROM. IR IR BLUE UV Hidra CPA Ti:Sa Amplifier RGA + 2 MP Mira Ti:Sa Oscillator THG DAZZLER TeO2 UV Stretcher
9
PULSE SHAPING: FREQ. DOMAIN
METHOD:COMPENSATE AMPLIFIER 2nd ORDER AND HIGHER MEASURING 1st 2nd 3rd HARMONIC & COMPARING WITH CALCULATIONS CHANGING CHIRP TERM & FIXING HIGH ORDER DAZZLER Stretcher Amplifier (RGA) AMPLIFIER Power Amplifier (Multipass) 2nd ORDER COMPENSATION Ф2=25000 fs2 Compressor 1st H. 800nm 2nd H. 400nm TO UPCONVERSION 3rd H. 266nm
10
PULSE SHAPING: FREQ. DOMAIN
1st H. 800nm 2nd H. 400nm 3rd H. 266nm
11
PULSE SHAPING: TIME/FREQ. DOMAIN
CHANGING CHIRP FOCALIZING UV
12
X-CORRELATOR UV BBO CRYSTAL BLUE IR DELAY LINE
-HIGH RESOLUTION (PROBE BEAM) -REMOTE CONTROLLED UV BBO CRYSTAL BLUE IR DELAY LINE
13
AND SPECTRUM MEASUREMENTS
X-CORRELATOR TILT OF 2nd HARM CRYSTAL GOOD MATCH WITH THEORY AND SPECTRUM MEASUREMENTS
14
X-CORRELATOR t t BBO SOLUTIONS PLANNED NEED OF A REFERENCE
UV STRETCHER GIVES SPATIAL DISPLACEMENT ON WAVELENGHTS INTERACTION VERY SENSITIVE TO BEAMS DISPLACEMENTS, TRANSVERSE DIMENSIONS, POWER OF THE BEAMS t SOLUTIONS PLANNED NEED OF A REFERENCE STREAK CAMERA UPGRADE FOR UV t BBO
15
TIMING: JITTER MEASUREMENTS (LASER SIDE)
Synchro Lock RF Reference R&S 2,856 GHz f/36 PLL2 f X 9 LO Mira Ti:Sa Oscillator BPF 9th H. MIXER 2 LO PLL1 BPF Fundam. MIXER 1 DRIVING SYSTEM f=c/2L PZT GALVO L
16
INTERNAL TIMING : RF POW TRIG ?
79,3 MHz SYNC.IN SDG RF system 4 µs before laser beam 10 Hz f/100 REP. RATE IN DELAY GENER. f/100 EXT. LINE SYNCH. QSW PC1 PC2 10 Hz 10 Hz 1 KHz Evolution Nd:YLF Continuum Nd:Yag Verdi Nd:YVO4 Hidra CPA Ti:Sa Amplifier RGA + 2 MP Mira Ti:Sa Oscillator THG DAZZLER TeO2 UV Stretcher
17
TRANSFER LINE CCD FP PIPE CLEAN ROOM Cathode
YAG CCD M5 M1 FP L1 PIPE Computer MM G CLEAN ROOM L2 L4 W C2 L3 C1 Cathode - Positioning Feedback Ready Optics Arriving Optical Table Arriving M3 M2 M4 r
18
CONCLUSIONS PERFORMING SYSTEM PULSE SHAPING IN PROGRESS
CONTACTS FOR OTHER WAYS NEED OF EFFICIENT TIME DIAGNOSTIC SYNCHRONIZATION IN AGREEMENT WITH SPECS WAITING LAST COMPONENTS FOR TRANSFER LINE MOUNTING DEVELOPED SOFTWARE FEEDBACK FOR POSITIONING STABILITY