Retentive On Delay Timers
MECH 1500 Retentive On Delay Timers Retentive – accumulates total time instruction has been energized and retains it when it de-energizes, meaning that it resumes timing when it is energized again. Application: Pumping applications. If a pump stops in the middle of filling, it can pick back up where it started.
2
Retentive On Delay Timers
MECH 1500 Retentive On Delay Timers Begins to time when it is first energized. Contacts remain off while it is timing If de-energized before preset time has elapsed, it continues to time. Contacts energize after the preset time has elapsed. Example: Used in applications where the total operating time of a machine must be tracked for preventative maintenance
3
Retentive On Delay Timers
MECH 1500 Retentive On Delay Timers Reset Instruction– Output instruction that resets retentive timer instructions having the same address.