Volume 2, Issue 1, Pages 14-15 (January 2017)
Successful removal of a surgical clip eroded into the hepaticojejunostomy site by use of a short-type single-balloon enteroscope Hideaki Koga, MD, Akio Katanuma, MD, Toshifumi Kin, MD, Kei Yane, MD, Hiroyuki Maguchi, MD, PhD VideoGIE Volume 2, Issue 1, Pages (January 2017) DOI: /j.vgie Copyright © 2016 The Authors Terms and Conditions
2
Figure 1 Coronal reconstruction of contrast-enhanced CT view showing mild dilatation of the bile duct with an enhancing wall (yellow arrow) and the surgical clips after laparoscopic cholecystectomy near the hepaticojejunostomy site. VideoGIE 2017 2, 14-15DOI: ( /j.vgie ) Copyright © 2016 The Authors Terms and Conditions
3
Figure 2 Surgical clip eroded into the bile duct at the anastomotic site. VideoGIE 2017 2, 14-15DOI: ( /j.vgie ) Copyright © 2016 The Authors Terms and Conditions
4
Figure 3 ERCP view showing obstruction of the bile flow at the level of the surgical clip. VideoGIE 2017 2, 14-15DOI: ( /j.vgie ) Copyright © 2016 The Authors Terms and Conditions
5
Figure 4 Extraction of the clip with biopsy forceps.
VideoGIE 2017 2, 14-15DOI: ( /j.vgie ) Copyright © 2016 The Authors Terms and Conditions
6
Figure 5 Clip after removal.
VideoGIE 2017 2, 14-15DOI: ( /j.vgie ) Copyright © 2016 The Authors Terms and Conditions
7
Figure 6 Direct per-oral cholangioscopic view showing no bile duct wall injury and no other clips remaining in the proximal bile duct. VideoGIE 2017 2, 14-15DOI: ( /j.vgie ) Copyright © 2016 The Authors Terms and Conditions