Presentation is loading. Please wait.

Presentation is loading. Please wait.

Current status of estimation of Eγ resolution

Similar presentations


Presentation on theme: "Current status of estimation of Eγ resolution"— Presentation transcript:

1 Current status of estimation of Eγ resolution
12/19(Tue) analysis meeting Y.Kato

2 To know the Eγ resolution is equal to know the momentum resolution!
Strategy If reaction is assumed, Eγ is calculated analytically from measured momentum. In the case of γ p → k+ Λ(1116), To know the Eγ resolution is equal to know the momentum resolution!

3 LLH2 run25452-25968 Analyzed data …LLH2 run23690-24058
Situation is different in these runs. →later

4 ・σfromΔp is estimated from MC.
γ p → k+ Λ(1116) γ p → π+ π- p ΔEγ(GeV) Momentum of k+(GeV/c) Eγ(GeV) ・σfromΔp is estimated from MC. ・vertex,decay-in-flight,chi2probability,ybar cut is included. It is neccesary to investigate momentum resolution of MC and real data is differnte or not.

5 → MC γ p →k+ Λ(1116)→k+ p pi- Real data γ(p,p pi-)X line+gauss fit
Check the invariant mass of real data and MC γ p →k+ Λ(1116)→k+ p pi-  Real data line+gauss fit 3sigma cut is applied M(ppi-) γ(p,p pi-)X σ=1.30±0.03MeV MC σ=1.24MeV

6 Smear the momentum resolution of MC
If ΔEγ is assumed , momentum resolution of real data can be obtained from missing mass. ΔEγ is assumed to be 12MeV MC black:Real data Red :MC smear ΔP(GeV/c) σ=1.31MeV Pk+(GeV/c)

7 γ p → k+ Λ(1116) ΔE after smear of MC for various mode
Red: Before smear black: after smear ΔEγ Eγ(GeV) Fit by constant value→11.9MeV±0.1

8 γ p → pi+ pi- p Red: Before smear black: after smear ΔEγ=11.8MeV±0.1

9 γ p → k+ k- p Red: Before smear black: after smear ΔEγ=10.7MeV±0.3

10 The hint for the reason of inconsistency between real data and MC
number of hits used in the tracking Real data MC number of hits removed in the tracking

11 γ p →k+ Λ(1116) Red: nhits<16 Black: nhits>=16 ΔEγ(GeV) Pk+(GeV/c)

12 Run dependence γp → k+ Λ γp → π+ π- p run23690-24058 run23690-24058
pk+(GeV/c) change of ΔEγ or Δp ?

13 check the invariant mass
run run σ=1.30±0.03MeV σ=1.26±0.04MeV

14 How large invariant mass change if run dependence of missing-mass
is all due to the change of momentum resolution? smear to adjust run smear to adjust run σ=1.31MeV σ=1.47MeV

15 γp→pi+pi-p vty(mm) VTY dependence run23690-24058 run25452-25968
black: Red: γp→pi+pi-p ΔE(GeV) vty(mm)

16 Summary ・Validity of momentum resolution in MC is essential to determine Eγ resolution. ・Invariant mass study indicates momentum resolution is under estimated in MC. ・Simple smearing makes inconsistency. ・Number of hits is different in real data and MC ・Run dependence of missing mass resolution can’t explain by the change of momentum resolution.


Download ppt "Current status of estimation of Eγ resolution"

Similar presentations


Ads by Google