Advances in Experimental Percutaneous Pulmonary Valve Replacement

Similar presentations


Presentation on theme: "Advances in Experimental Percutaneous Pulmonary Valve Replacement"— Presentation transcript:

1 Advances in Experimental Percutaneous Pulmonary Valve Replacement
Tim Attmann, MD, Thomas Jahnke, MD, René Quaden, MD, Andreas Boening, MD, PhD, Stefan Muller-Hulsbeck, MD, PhD, Jochen Cremer, MD, PhD, Georg Lutter, MD, PhD  The Annals of Thoracic Surgery  Volume 80, Issue 3, Pages (September 2005) DOI: /j.athoracsur Copyright © 2005 The Society of Thoracic Surgeons Terms and Conditions

2 Fig 1 Valved segment of a bovine jugular vein inside the nitinol stent: (a) during suturing process and (b) view from above on a bicuspid valve with thin, transparent cusps. The Annals of Thoracic Surgery  , DOI: ( /j.athoracsur ) Copyright © 2005 The Society of Thoracic Surgeons Terms and Conditions

3 Fig 2 Endoscopic view from above on a valved stent in the in vitro pulsatile flow system: (a) prompt and wide opening of the cusps during systole and (b) complete closure during diastole. The Annals of Thoracic Surgery  , DOI: ( /j.athoracsur ) Copyright © 2005 The Society of Thoracic Surgeons Terms and Conditions

4 Fig 3 Preimplantation angiography of the right ventricular outflow tract and the pulmonary artery. The annulus is 20.3 mm. Note: there is little contrast agent in the right atrium (arrow). The Annals of Thoracic Surgery  , DOI: ( /j.athoracsur ) Copyright © 2005 The Society of Thoracic Surgeons Terms and Conditions

5 Fig 4 Three-dimensional computed tomography reconstructions of the heart in volume rendering technique modus after implantation of a valved stent in the pulmonary position. Spin degrees: −22 for the left upper picture, +23 for the left lower picture, +68 for the right upper picture, and +90 for the right lower picture. The Annals of Thoracic Surgery  , DOI: ( /j.athoracsur ) Copyright © 2005 The Society of Thoracic Surgeons Terms and Conditions

6 Fig 5 Completion angiography after valved stent deployment. No neovalve insufficiency is detected. The Annals of Thoracic Surgery  , DOI: ( /j.athoracsur ) Copyright © 2005 The Society of Thoracic Surgeons Terms and Conditions

7 Fig 6 Typical shape of pressure curves during catheter pullback through the valved stent. The Annals of Thoracic Surgery  , DOI: ( /j.athoracsur ) Copyright © 2005 The Society of Thoracic Surgeons Terms and Conditions

8 Fig 7 Fluoroscopy with application device in situ. Note the alteration of the geometry of cardiac structures induced by the extra-stiff guidewire and by the application device. The black arrow indicates the position of the pulmonary annulus before introduction of the guide wire and the application device. The white arrow indicates the new position of the pulmonary annulus. The Annals of Thoracic Surgery  , DOI: ( /j.athoracsur ) Copyright © 2005 The Society of Thoracic Surgeons Terms and Conditions

9 Fig 8 (a) Perfect position of the valved stent. The right ventricular outflow tract and pulmonary artery are cut longitudinally. The arrow indicates a native pulmonary valve leaflet. (b) Valved stent after explantation. Note the thin and transparent leaflets. The small defect (arrow) disappeared during water rinse testing. (c) Imprint of the valved stent on the native pulmonary valve and on the intima of the right ventricular outflow tract and pulmonary trunk. Minor endocardial lesions of the right ventricle are indicated by the arrow. The Annals of Thoracic Surgery  , DOI: ( /j.athoracsur ) Copyright © 2005 The Society of Thoracic Surgeons Terms and Conditions