SoLID EC photonsensor
2
Field (1.5T) Insensitive photonsensor
APD Pro: not sensitive to field, large QE (0.8) Con: radiation sensitive, low gain , bias V sensitive, noise SiPM Pro: not sensitive to field, high gain (1e6) Con: radiation sensitive (worse than APD), bias V sensitive, noise VPT (Vacuum Phototriode) Pro: radiation hard, high rate capability, not very sensitive to field within certain angle Con: low gain 10-40 Finemesh PMT con: only works up to 2.5kG within certain angle, expensive ($1600?) Previously used PMT R
3
estimation 2e4 photons for 2GeV electron 50ns pulse width 0.8 QE (APD)
Gain 100 (APD) 50 ohm 2e4/50e-9*.8*1.6e-19*100*50=0.3mV Need 1e3 amplification
4
Panda APD CMS 5x5mm2 10x10mm2 new excellent performance
in collaboration with Hamamatsu Photonics CMS 5x5mm2 10x10mm2 new excellent performance at RT and T = –25oC radiation resistent up to 1013 protons in particular at T = -25oC final concept: LAAPDs/crystal, separately readout dimensions 7 x 14 mm2 July 8, 2012 CALOR R.W.Novotny
5
spectrum Panda APD see light below 500nm S8664-1010 (10mmx10mm)
C shortwave length type (5mmx5mm)
6
Panda preamplifiers (low noise, low power)
design of descrete components for prototype studies 18mm ASIC (APFEL) large dynamic range 2 channels/ 2 ranges overall range 1 – noise level (cooled) << 2 MeV July 8, 2012 CALOR R.W.Novotny
7
HallD BCAL SiPM Dark rate increase by factor of 10
for 10e9 eq 1MeV neutron preproduction unit of S (X) MPPC with 50 m pixels, equivalent to new S12045. SPMArray unit based on ceramic design with 35 m pixels - Wafer Batch Code X4151- 05 using SPM3035 design.
8
VPT Field insensitive within 30 degree at 1.8T
Preamiplifier needs to be close to VPT RIE St. Petersburg, Russia Tetrode (photo cathode, 2 dynodes, anode) G = 24 – 45 QE = 14 – 20%
9
Finemesh PMT Has closely spaced mesh dynodes
Need to be around 30 degree to work with 1.5T
10
backup
11
WLS has light around 500nm
12
Hamamatsu has no APD for 500nm? http://sales.hamamatsu.com/index.php?id=13196302
13
Photon radiation 60Co photon 1.2MeV
1e12 photon is 1.2e9 GeV or J The remeasurements of the APD characteristics have been done after a storage of the diodes at room temperature in the order of one month
14
Neutron radiation