Download presentation
Presentation is loading. Please wait.
Published byTroels Hald Modified over 5 years ago
1
CIC method applied to the KASCADE-Grande muon data
Juan Carlos Arteaga-Velázquez for the KASCADE-Grande Collaboration Institute of Physics and Mathematics Universidad Michoacana CIC method applied to KG muon data – J.C. Arteaga Malargüe 2008, PAO Coll. Meeting
2
The KASCADE-Grande experiment
KASCADE-Grande (Karlsruhe Shower Core and array detector) E = eV Grande detectors measure e/ + component simultaneously KASCADE shielded scintillators allow to measure component of EAS. (E > 230 MeV sec) CIC method applied to KG muon data – J.C. Arteaga Malargüe 2008, PAO Coll. Meeting
3
Reconstruction of N Measured densities in KASCADE (r) = N f(r)
N = n(ri) / [f(ri)Aicos(z)] f(r) known from MC simulations N corrected from reconstruction systematics CIC method applied to KG muon data – J.C. Arteaga Malargüe 2008, PAO Coll. Meeting
4
Muon spectra KG data Teff = days Events 53423 28053 7082 1657 CIC method applied to KG muon data – J.C. Arteaga Malargüe 2008, PAO Coll. Meeting
5
Integral muon spectra Apply cut at constant Jcut
For a given Jcut, get N() CIC method applied to KG muon data – J.C. Arteaga Malargüe 2008, PAO Coll. Meeting
6
Muon attenuation curves
Get attenuation curves Choose the mean CIC method applied to KG muon data – J.C. Arteaga Malargüe 2008, PAO Coll. Meeting
7
Reference angle Find reference angle ref for normalization:
N24 of each event For the moment use only showers < 42o CIC method applied to KG muon data – J.C. Arteaga Malargüe 2008, PAO Coll. Meeting
8
Muon spectra Good agreement between muon spectra for vertical showers
CIC method applied to KG muon data – J.C. Arteaga Malargüe 2008, PAO Coll. Meeting
9
Muon spectra Difference between MC and KG muon attenuation lengths
FLUKA/QGSJET II CIC method applied to KG muon data – J.C. Arteaga Malargüe 2008, PAO Coll. Meeting
10
Muon spectrum for vertical showers
CIC method applied to KG muon data – J.C. Arteaga Malargüe 2008, PAO Coll. Meeting
11
Muon number systematic uncertainties
CIC method applied to KG muon data – J.C. Arteaga Malargüe 2008, PAO Coll. Meeting
12
Summary Using the CIC method, we compared the muon spectra for different without the influence of MC models. Good agreement among reconstructed muon spectra from KG data on vertical showers with the CIC method. Simulated Λ is different from the one obtained from the CIC method and the KG data. CIC method applied to KG muon data – J.C. Arteaga Malargüe 2008, PAO Coll. Meeting
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.