STELR Ranging Multimeter
2
It has part code LB313-010 marked on the case
STELR Ranging Multimeter These instructions refer the STELR Ranging Multimeter that was introduced during 2017 It has part code LB marked on the case The older (non-ranging) multimeter has the part code ST marked on the case Instructions for the older multimeter can be found on the STELR website here: energy/#how-to-use
3
How to measure resistance Other measurements
STELR Ranging Multimeter Features Input jacks Turning on (and off) LCD display How to measure voltage How to measure current How to measure resistance Other measurements Use of the ‘select’ button Use of the ‘hold’ button
4
STELR Ranging Multimeter
LCD display
5
STELR Ranging Multimeter
LCD display Select button
6
STELR Ranging Multimeter
LCD display Hold button Select button
7
LCD display Hold button Select button Rotary switch
STELR Ranging Multimeter LCD display Hold button Select button Rotary switch
8
LCD display Hold button Select button Rotary switch Shock-proof case
STELR Ranging Multimeter LCD display Hold button Select button Rotary switch Shock-proof case
9
LCD display Hold button Select button Rotary switch Shock-proof case
STELR Ranging Multimeter LCD display Hold button Select button Rotary switch Shock-proof case Input jacks
10
STELR Ranging Multimeter
Please also refer to the instruction leaflet accompanying each multimeter.
11
STELR Ranging Multimeter
Input jacks
12
The centre jack is a common negative
STELR Ranging Multimeter The centre jack is a common negative Input jacks
13
The centre jack is a common negative
STELR Ranging Multimeter The centre jack is a common negative The right jack should be used as positive for all measurements except when measuring between 200mA and 10A Input jacks
14
STELR Ranging Multimeter
Input jacks
15
STELR Ranging Multimeter
Note that when connected this way the maximum values are 600V and 200mA. A 200mA fuse protects this circuit and the fuse will ‘blow’ if these values are exceeded. Input jacks
16
The centre jack is a common negative
STELR Ranging Multimeter The left jack should only be used as positive for when measuring between 200mA and 10A. For example when using the wind turbine. The centre jack is a common negative Input jacks
17
STELR Ranging Multimeter
Input jacks
18
STELR Ranging Multimeter
Note that when connected this way the maximum values for current is 10A. This circuit has no fuse for protection and a current of 10A can be passed through the circuit for a maximum of 10 seconds before the multimeter will be damaged. Input jacks
19
Turning the multimeter on
STELR Ranging Multimeter Turning the multimeter on
20
Rotary switch in OFF position
STELR Ranging Multimeter Rotary switch in OFF position
21
Turn rotary switch to any other setting to turn on
STELR Ranging Multimeter Turn rotary switch to any other setting to turn on
22
The display will activate once the multimeter is turned on
STELR Ranging Multimeter The display will activate once the multimeter is turned on Turn rotary switch to any other setting to turn on
23
https://stelr.org.au/stelr-modules/renewable-energy/#how-to-use
STELR Ranging Multimeter If the display does not activate, it means either the battery is flat or the fuse has blown. Go to to find out how to change the battery and the fuse.
24
https://stelr.org.au/stelr-modules/renewable-energy/#how-to-use
STELR Ranging Multimeter If the display does not activate, it means either the battery is flat or the fuse has blown. Go to to find out how to change the battery and the fuse. The multimeter will automatically power off if unattended for over 5 minutes. To reactivate, turn to off and then to any other setting.
25
STELR Ranging Multimeter
LCD display
26
LCD display A reading of ‘0L’ indicates that the multimeter is
STELR Ranging Multimeter A reading of ‘0L’ indicates that the multimeter is off-scale. LCD display
27
STELR Ranging Multimeter
Measuring voltage
28
Measuring voltage There are two voltage settings
STELR Ranging Multimeter There are two voltage settings Measuring voltage
29
STELR Ranging Multimeter
AC Voltage Measuring voltage
30
STELR Ranging Multimeter
There are no STELR activities that require the use of AC. Students should never use this setting. AC Voltage Measuring voltage
31
STELR Ranging Multimeter
DC Voltage Measuring voltage
32
Measuring voltage DC Voltage
STELR Ranging Multimeter DC Voltage When measuring DC voltage students should always use the right hand socket for the positive lead Measuring voltage
33
Measuring voltage DC Voltage
STELR Ranging Multimeter DC Voltage The multimeter is auto ranging for voltage and will measure any voltage up to 1000V on this setting. Measuring voltage
34
STELR Ranging Multimeter
Measuring resistance
35
Measuring resistance There is one resistance setting
STELR Ranging Multimeter There is one resistance setting Measuring resistance
36
Measuring resistance There is one resistance setting
STELR Ranging Multimeter There is one resistance setting When measuring resistance, students should always use the right hand socket for the positive lead. Measuring resistance
37
Measuring resistance There is one resistance setting
STELR Ranging Multimeter There is one resistance setting The multimeter is auto ranging for resistance and will measure any resistance up to 40 M on this setting. Measuring resistance
38
STELR Ranging Multimeter
Measuring current
39
Measuring current There are three different current settings
STELR Ranging Multimeter There are three different current settings Measuring current
40
STELR Ranging Multimeter
When the dial is set to any of the three current settings, the default is to measure direct current (DC) There are three different current settings Measuring current
41
STELR Ranging Multimeter
To measure AC current, press the select switch. This toggles between AC and DC current There are no STELR activities that require the use of AC. Students should never use this setting. Measuring current
42
STELR Ranging Multimeter
To measure current, always start with the meter set to amps Measuring current
43
STELR Ranging Multimeter
To measure current, always start with the meter set to amps When using the amps setting the left-hand positive socket must be used Measuring current
44
STELR Ranging Multimeter
If the reading is less than one amp, move the dial to the milliamp position Measuring current
45
STELR Ranging Multimeter
If the reading is less than one amp, move the dial to the milliamp position When using the milliamps setting the right-hand positive socket must be used Measuring current
46
STELR Ranging Multimeter
If the reading is less than one milliamp, move the dial to the microamp position Measuring current
47
STELR Ranging Multimeter
If the reading is less than one milliamp, move the dial to the microamp position When using the microamps setting the right-hand positive socket must be used Measuring current
48
STELR Ranging Multimeter
Other measurements
49
STELR Ranging Multimeter
There are other settings on the multimeter that can be used for testing frequency, capacitance, transistors and diodes. These are not required for use as part of the STELR program, but may be of general use in other programs. For detailed instructions on the use of these settings, please refer to the Digital Multimeter Operator’s Manual sheet included with the multimeters.
50
STELR Ranging Multimeter
Capacitance
51
STELR Ranging Multimeter
Capacitance Diode testing
52
STELR Ranging Multimeter
Frequency Capacitance Diode testing
53
Frequency Capacitance Diode testing Transistor testing
STELR Ranging Multimeter Frequency Capacitance Diode testing Transistor testing
54
STELR Ranging Multimeter
Hold button
55
When using the wind turbine, a fluctuating current is measured.
STELR Ranging Multimeter When using the wind turbine, a fluctuating current is measured. This is a result of the variable wind flow from the fan. Pressing the hold button, ‘freezes’ the reading. Pressing the hold button a second time returns the meter to the variable measurements. Students can be encouraged to take three readings, five or 10 seconds apart, and average them for a more accurate measurement.
56
STELR Ranging Multimeter
Press hold button to ‘freeze’ the reading. Press again to ‘unhold’ the display.
57
Backlighting the screen
STELR Ranging Multimeter Backlighting the screen
58
STELR Ranging Multimeter
Press and hold the ‘hold’ button for two seconds until it beeps, and the screen will light up
59
Press again to turn off the backlight.
STELR Ranging Multimeter Press again to turn off the backlight. It is recommended that use of the backlight button is minimised, as it tends to drain the battery quite quickly.
60
STELR Ranging Multimeter
stelr.org.au