Presentation is loading. Please wait.

Presentation is loading. Please wait.

Observed CE/RE Failures in the Display Product CE(Conducted Emission )

Similar presentations


Presentation on theme: "Observed CE/RE Failures in the Display Product CE(Conducted Emission )"— Presentation transcript:

1 Observed CE/RE Failures in the Display Product CE(Conducted Emission )
Failure observed in 90MHz range RE(Radiated Emission ) Failure Seen in 896MHz . With the near field probe test observed this emission is coming From the LVDS input section from Interface connector to Deserializer Input . ** x929 Serializer is using and the clock frequency is 90MHz from serializer . Deserializer to LCD clock is 45MHz .

2 Deserializer DS90UB948TNKDTQ1 Interface Connector TOP Layer 1 Deserializer Input Section Layout

3 Deserializer Input Section Layout
GND Layer 2 Is this split plane is okay for The differential signal ?. We are controlling impedance Of 100Ω by matching the trace length. FPD_R0_P Trace length : mm FPD_R0_N Trace length : mm. Deserializer Input Section Layout

4 Power Layer 3 Deserializer Input Section Layout

5 Bottom Layer 4 Deserializer Input Section Layout

6 TOP Layer 1 Deserializer Output Section Layout

7 GND Layer 2 Deserializer Output Section Layout

8 Power Layer 3 Deserializer Output Section Layout

9 Bottom Layer 4 Deserializer Output Section Layout


Download ppt "Observed CE/RE Failures in the Display Product CE(Conducted Emission )"