Day 2 Training - Technical
Sept. 18, 2008 Bus Comparisons Process Networking (F)
4
Protocol Overviews Protocol Description Special Features
Ideal Applications Digital communication on 4 to 20mA point to point wiring. Operating signal typically on 4 to 20mA Now available in wireless version for digital signal Point to point analog process controls in PID loop CAN based 4-wire (2 power; 2signal) network with up to 62 devices per segment. Length is speed dependent. Suitable for discrete or analog applications. Mainly used for motor controls(VFDs) or in factory automation with Rockwell/Allen Bradley PLCs Communication over RS485 (4000 ft/1200 meters and up to 32 devices) with separate power. Modbus+ used as an update for higher speed applications Used to connect remote I/O into legacy control systems. Also used with electric actuators Basic network supplying power and digital signal with up to 61 devices per segment. Originally designed as Profibus DP sub-Layer Very simple to install, commission and use. Use as sub layer to input discrete devices. May use with Modbus, Profibus DP, EtherNet and DeviceNet RS 485 version with up to 32 devices with on 4000 ft (length is speed dependent). PA version simiiar to FF. DP (RS485) capable of reading over 1000 input points in less than 1ms. Widely used in factory and process for both discrete and analog devices. Object oriented network up to 1900m long interconnecting 12 to 20 devices on a segment with power & signal. Build up a PID loop directly connecting function blocks. Process applications using PID loops and/or intrinsically safe hazard protection
5
FieldLink Cabinets & Enclosures
6
Topics Covered Junction Module (JM™) Compact Field Wiring Module Designed for Explosion Proof and Nonincendive Applications FieldBlock (FB, FN) Field Wiring Module Designed for Flexible Cable and Wiring Systems FieldRack (FR) Field Wiring Cabinet Designed for Enclosing Larger Field Networking Using DIN Rail System
7
JM Enclosure Features Anodized Aluminum is Epoxy Coated for Corrosion Resistance Suitable for use in heavy wash down and submersible applications with NEMA 4, 4X and 6 ratings Housing Rated for Class I & II Division 1 & 2 Groups B, C, D and Approved (FM Approved) Clear Lexan® (Div 2) cover available to view LED functions No Seal Fittings required in both Division 1 & 2 hazardous areas
8
JM Functions Drop Connectors - Passive 1-2 (2 & 4 Wire Bus) - Protected 1-1 (2 Wire Bus) mA or 240mA Switched Drop Connectors - Protected 1-1 (2 Wire Bus) mA or 240mA - Optional Factory Sealed Leads (Remove Field Device in Div Areas without Seal Fitting)
9
JM Functions I/O Modules - DeviceNet, FF H1, Modbus & AS-I
Relay Modules (Motor Controls) - DeviceNet, FF H1, Modbus & AS-I - Relays Fused for 2 Amps - Independent - Interlocking
10
JM Functions I/O with Integral Cyclone - Cv Brass or Stainless Steel - Low Power Solenoid Pilot - Piezo Pilot (FF Bus Powered) FF Bus Powered I/O and Hawkeye Sensors - Hawkeye Sensor run on ultra-low Power - May create specials with Integral Piezo Cyclone & Hawkeye Sensors
11
JM Functions Other Applications Repeater Power Conditioner
Repeater and Power Conditioner Junction Enclosure (6-Point or 12-Point Terminal Strip)
12
FieldBlock Enclosure Features
Lexan Enclosure is Durable and Corrosion Proof Suitable for use in heavy wash down and submersible applications with NEMA 4, 4X and 6 ratings Multiple Connector or Cable Gland Options Conveniently Interface with Flexible Wiring Systems Compact Design Minimizes Space Requirements Use the Partnership Program for Special Connector and/or Cable Gland Configurations
13
FieldBlock Functions Drop Connectors - Passive 1-4 (2 & 4 Wire Bus) - Protected 1-4 (2 Wire Bus) mA or 240mA Switched Drop Connectors - Protected 1-4 (2 Wire Bus) mA or 240mA
14
FieldBlock Functions I/O Modules - DeviceNet, FF H1, Modbus & AS-I
Relay Modules (Motor Controls) - DeviceNet, FF H1, Modbus & AS-I - Relays Fused for 2 Amps - Independent - Interlocking
15
FieldBlock (FN) Enclosure Features
Day 2 Training - Technical Sept. 18, 2008 FieldBlock (FN) Enclosure Features Anodized Aluminum Enclosure is Durable and Corrosion Proof Suitable for use in heavy wash down and submersible applications with NEMA 4, 4X and 6 ratings Multiple Connector or Cable Gland Options Conveniently Interface with Flexible Wiring Systems Compact Design Minimizes Space Requirements Process Networking (F)
16
FieldBlock (FN) Functions
Drop Connectors - Passive 1-6 (2 & 4 Wire Bus) - Protected 1-4 (2 Wire Bus) mA or 240mA Switched Drop Connectors - Protected 1-6 (2 Wire Bus) mA or 240mA
17
FieldRack Enclosure Features
Durable, Corrosion Proof Lexan Construction Large Sizes for Enclosing Multiple DIN Rail Components (DIN Rail Pre-attached) Completely Sealed and Vapor Tight Rated for use in Class I Div 2 Areas with Approved Components Easy to Access with Hinged Door May be Easily Fitted with Cable Glands, Conduit Hubs or Connectors. FRN1008 FRN1212