Download presentation
Presentation is loading. Please wait.
Published byΩσαννά Δράκος Modified over 5 years ago
1
Angioplasty Balloon-associated Coronary Debris and the EZ FilterWire
Vascular Protection in High-Risk Non-ST Elevation Acute Coronary Syndromes Angioplasty Balloon-associated Coronary Debris and the EZ FilterWire M Webster Auckland City Hospital Auckland, NZ on behalf of R Whitbourn, D McLean, C Juergens, H Lowe, G Barbeau, P Matsis, D Walters, G Devlin, W Hui, D Brieger, G Tully and the A-F Investigators
2
Study Design Prospective, multicenter, unblinded, two-arm, randomized trial Selected high-risk patients with nonSTEMI acute coronary syndromes PCI using the BSC FilterWire vs standard PCI without FilterWire 150 patient pilot for pivotal protocol Provision for two additional cohorts - up to 450 patients
3
Study Population Non ST elevation ACS with "high risk" clinical features during 24 hours prior to angiography elevated troponin angina at rest dynamic ST or T wave changes (not ST elevation MI) Culprit lesion with "high risk" angiographic features (2 or more of the following) intra-coronary filling deficit consistent with thrombus lesion ulceration eccentric shape irregular or scalloped border abrupt edges to the lesion lesion length >20 mm
4
Primary Endpoint In-hospital MACE
- death, recurrent myocardial infarction (CK-MB>3x normal), emergency CABG, repeat target vessel revascularisation
5
Baseline Characteristics
FilterWire Control Patients, n Age, mean (sd) 58(11) 60(13) Male, % European, % Previous angina, % Diabetes, % Smoker – never, % Hypertension, % Dyslipidemia, %
6
Primary Endpoint
7
Secondary Endpoints FilterWire Control MACE 30 day, % 12 11
Change CK-MB (20) 4.1(6) Change troponin T (0.7) 0.4(0.6) Device success, % n/a Embolic recovery, % n/a Post-PCI TIMI III, %
8
Why Was There No Benefit With FilterWire?
Wrong patho-physiology? embolism occurs during PCI for nonSTEMI - histology, thrombectomy, MRI Wrong lesions selected? only 42% had emboli captured Incomplete protection? embolism with positioning the device filter mouth/ vessel wall apposition incomplete side branch protection small particle embolism Insufficient study population - type II error
9
Summary A-F is the only randomised trial of a vascular protection device undertaken in non-STEMI acute coronary syndrome patients No difference between FilterWire and control groups in in-hospital MACE or post-proceure CK-MB or troponin elevation Routine use of vascular protection devices in such patients does not appear warranted
Similar presentations
© 2025 SlidePlayer.com. Inc.