Download presentation
Presentation is loading. Please wait.
1
Stent Grafting Acute Aortic Dissection: Comparison of DeBakey Extent IIIA Versus IIIB
Amr Arafat, MD, Eric E. Roselli, MD, Jay J. Idrees, MD, Ke Feng, BS, Lauren Banaszak, BS, Matthew Eagleton, MD, Venu Menon, MD, Lars G. Svensson, MD, PhD The Annals of Thoracic Surgery Volume 102, Issue 5, Pages (November 2016) DOI: /j.athoracsur Copyright © 2016 The Society of Thoracic Surgeons Terms and Conditions
2
Fig 1 Survival for DeBakey type IIIA (black) vs DeBakey type IIIB (gray) acute complicated aortic dissection after thoracic endovascular aortic repair. Each step represents a death. Number at risk and SE are represented below the graph. The Annals of Thoracic Surgery , DOI: ( /j.athoracsur ) Copyright © 2016 The Society of Thoracic Surgeons Terms and Conditions
3
Fig 2 Aortic reintervention for DeBakey type IIIA vs DeBakey type IIIB acute complicated aortic dissection after thoracic endovascular aortic repair. Each step represents a death. Number at risk and SE are represented below the graph. The Annals of Thoracic Surgery , DOI: ( /j.athoracsur ) Copyright © 2016 The Society of Thoracic Surgeons Terms and Conditions
4
Fig 3 Representation of change in aortic diameter at baseline vs 12 months after thoracic endovascular aortic repair measured outer wall to outer wall in a plane orthonormal to the centerline of blood flow at various levels in DeBakey type IIIA vs DeBakey type IIIB acute complicated aortic dissection. *Denotes significant difference between the baseline and 12-month measurement. The Annals of Thoracic Surgery , DOI: ( /j.athoracsur ) Copyright © 2016 The Society of Thoracic Surgeons Terms and Conditions
5
Fig 4 Representation of change in true lumen area at baseline vs 12 months after thoracic endovascular aortic repair measured outer wall to outer wall in a plane orthonormal to the centerline of blood flow at various levels in DeBakey type IIIA vs DeBakey type IIIB acute complicated aortic dissection. *Denotes significant difference between the baseline and 12-month measurement. The Annals of Thoracic Surgery , DOI: ( /j.athoracsur ) Copyright © 2016 The Society of Thoracic Surgeons Terms and Conditions
6
Fig 5 Representation of change in the false lumen (FL) short-axis diameter at baseline vs 12 months after thoracic endovascular aortic repair measured in a plane orthonormal to the centerline of blood flow at various levels in DeBakey type IIIA vs DeBakey type IIIB acute complicated aortic dissection. *Denotes significant difference between the baseline and 12-month measurement. The Annals of Thoracic Surgery , DOI: ( /j.athoracsur ) Copyright © 2016 The Society of Thoracic Surgeons Terms and Conditions
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.