Presentation is loading. Please wait.

Presentation is loading. Please wait.

Endovascular Repair of Acute Type B Aortic Dissection: Long-Term Follow-Up of True and False Lumen Diameter Changes  Maria Schoder, MD, Martin Czerny,

Similar presentations


Presentation on theme: "Endovascular Repair of Acute Type B Aortic Dissection: Long-Term Follow-Up of True and False Lumen Diameter Changes  Maria Schoder, MD, Martin Czerny,"— Presentation transcript:

1 Endovascular Repair of Acute Type B Aortic Dissection: Long-Term Follow-Up of True and False Lumen Diameter Changes  Maria Schoder, MD, Martin Czerny, MD, Manfred Cejna, MD, Thomas Rand, MD, Alfred Stadler, MD, Gottfried H. Sodeck, MD, Roman Gottardi, MD, Christian Loewe, MD, Johannes Lammer, MD  The Annals of Thoracic Surgery  Volume 83, Issue 3, Pages (March 2007) DOI: /j.athoracsur Copyright © 2007 The Society of Thoracic Surgeons Terms and Conditions

2 Fig 1 A 70-year old woman with acute renal failure caused by acute type B aortic dissection. (A) Angiogram before stent graft implantation shows the entry tear located close to the left subclavian artery (LSA). (B) Compromised visceral, renal, and iliac arteries by a dynamic process. (C) Remarkable true lumen expansion after implantation of two Talent endoprostheses with overstenting of the LSA. (D) Restoration of blood flow in the abdominal branches and iliac arteries after stent grafting. The Annals of Thoracic Surgery  , DOI: ( /j.athoracsur ) Copyright © 2007 The Society of Thoracic Surgeons Terms and Conditions

3 Fig 2 Box plots show the differences of (A) true and (B) false lumen diameter changes between the preprocedural computed tomography imaging and the 1-year follow-up at the level of the stented segment (L1). The Annals of Thoracic Surgery  , DOI: ( /j.athoracsur ) Copyright © 2007 The Society of Thoracic Surgeons Terms and Conditions

4 Fig 3 Box plots show the differences of (A) true and (B) false lumen diameter changes between the preprocedural computed tomography imaging and the 1-year follow-up in the thoracic aorta at the level distal of the stent-graft (L2). The Annals of Thoracic Surgery  , DOI: ( /j.athoracsur ) Copyright © 2007 The Society of Thoracic Surgeons Terms and Conditions

5 Fig 4 Box plots show the difference of (A) true (B) and false lumen diameter changes between the preprocedural computed tomography imaging and the 1-year follow-up at the level of the celiac trunk (L3). The Annals of Thoracic Surgery  , DOI: ( /j.athoracsur ) Copyright © 2007 The Society of Thoracic Surgeons Terms and Conditions


Download ppt "Endovascular Repair of Acute Type B Aortic Dissection: Long-Term Follow-Up of True and False Lumen Diameter Changes  Maria Schoder, MD, Martin Czerny,"

Similar presentations


Ads by Google