Presentation is loading. Please wait.

Presentation is loading. Please wait.

Gluteus Medius Repair With Double-Row Fixation

Similar presentations


Presentation on theme: "Gluteus Medius Repair With Double-Row Fixation"— Presentation transcript:

1 Gluteus Medius Repair With Double-Row Fixation
J. W. Thomas Byrd, M.D.  Arthroscopy Techniques  Volume 2, Issue 3, Pages e247-e250 (August 2013) DOI: /j.eats Copyright © 2013 Elsevier Inc. Terms and Conditions

2 Fig 1 On viewing of a left hip, the viewing portal for the 30° arthroscope is posterior to the vastus lateralis ridge (VLR). Distally is a Clear-Trac working cannula (Smith & Nephew). A Healicoil anchor is being inserted from a proximal portal. A probe has been introduced anteriorly to retract the tendon while seating the anchor. © J. W. Thomas Byrd. Arthroscopy Techniques 2013 2, e247-e250DOI: ( /j.eats ) Copyright © 2013 Elsevier Inc. Terms and Conditions

3 Fig 2 A grasper assesses the mobility of the tendon. (A) Moving the tendon proximally exposes the bony footprint. (B) The tendon is mobilized distally over its insertion site. © J. W. Thomas Byrd. Arthroscopy Techniques 2013 2, e247-e250DOI: ( /j.eats ) Copyright © 2013 Elsevier Inc. Terms and Conditions

4 Fig 3 The anterior of 2 double-loaded Healicoil anchors is being inserted in the proximal portion of the bony footprint. © J. W. Thomas Byrd. Arthroscopy Techniques 2013 2, e247-e250DOI: ( /j.eats ) Copyright © 2013 Elsevier Inc. Terms and Conditions

5 Fig 4 The more posterior of the 2 Healicoil anchors is being inserted. The colored sutures of the anterior anchor are seen emerging from the anchor hole (arrow); these have already been passed in a mattress fashion through the proximal tendon. © J. W. Thomas Byrd. Arthroscopy Techniques 2013 2, e247-e250DOI: ( /j.eats ) Copyright © 2013 Elsevier Inc. Terms and Conditions

6 Fig 5 The 4 sutures from the 2 double-loaded anchors have been tied, leaving 1 suture limb from each knot to be incorporated into the distal fixation. © J. W. Thomas Byrd. Arthroscopy Techniques 2013 2, e247-e250DOI: ( /j.eats ) Copyright © 2013 Elsevier Inc. Terms and Conditions

7 Fig 6 The distal Footprint anchor is driven into place, incorporating 2 suture limbs from the proximal knots. © J. W. Thomas Byrd. Arthroscopy Techniques 2013 2, e247-e250DOI: ( /j.eats ) Copyright © 2013 Elsevier Inc. Terms and Conditions

8 Fig 7 The final repair construct is inspected with secure double-row fixation. © J. W. Thomas Byrd. Arthroscopy Techniques 2013 2, e247-e250DOI: ( /j.eats ) Copyright © 2013 Elsevier Inc. Terms and Conditions


Download ppt "Gluteus Medius Repair With Double-Row Fixation"

Similar presentations


Ads by Google