1 Welcome to PHOENIX CONTACT Masterversion 13 Electromagnetic and electronic circuit-breaker CLIPLINE complete

2 Masterversion 13 2 / Name / Department / Date UT 6-TMC M 0,5A … UT 6-TMC M 16A Circuit Breaker UT 6-TMC M Thermomagnetic Circuit Breaker as part of CLIPLINE complete UT 6-TMC M 0,5A UT 6-TMC M 1A UT 6-TMC M 2A UT 6-TMC M 4A UT 6-TMC M 5A UT 6-TMC M 6A UT 6-TMC M 8A UT 6-TMC M 10A UT 6-TMC M 12A UT 6-TMC M 15A UT 6-TMC M 16A Highlights

3 Masterversion 13 3 / Name / Department / Date Circuit Breaker UT 6-TMC M Two bridge channels for the standard FBS x-6 bridge Due to the plug bridge no need for wiring Time-saving

4 Masterversion 13 4 / Name / Department / Date 38 37 -F18 Circuit Breaker UT 6-TMC M Three positions for UC-TM12 or ZB 12 marking material. Enough space for big and easy readable designations. Clear marking for device and connection point information Fast and clear marking

5 Masterversion 13 5 / Name / Department / Date Circuit Breaker UT 6-TMC M Exact positioning of all markers High quality impression

6 Masterversion 13 6 / Name / Department / Date Circuit Breaker UT 6-TMC M 30% less space required Space-saving 12,3 17,5

7 Masterversion 13 7 / Name / Department / Date Circuit Breaker UT 6-TMC M If the circuit breaker is switched off you can see the white collar. Clear visibility of the switching status. This allows a fast identification of the faulty circuit. High availability

8 Masterversion 13 8 / Name / Department / Date Circuit Breaker UT 6-TMC M No competitive product in the market Phoenix Contact product

9 Masterversion 13 9 / Name / Department / Date Certification Body StandardApproved asFile-No.Approval Mark VDEIEC 60934 Circuit Breaker for Equipment ULUL 1077 Supplementary Protector ULCSA 22.2 No. 235 Supplementary Protector Approvals Circuit Breaker UT 6-TMC M

10 Masterversion 13 10 / Name / Department / Date mains input power supply 24 V DC magnetic valves, signal lamps, heating systems, industrial PC´s, fans… Application main application for UT 6-TMC M

11 Masterversion 13 11 / Name / Department / Date Circuit Breaker – Product Range TCP TMC TMCP ECP-E TCP/DC ECPEC-E

12 Masterversion 13 12 / Name / Department / Date Circuit Breaker Thermomagnetic protection Thermal protection Electronic protection

13 Masterversion 13 13 / Name / Department / Date Circuit Breaker - Shut-down behavior Thermal & magnetic Electronic Short CircuitApplication Overload Over- load

14 Masterversion 13 14 / Name / Department / Date Thermal Switch-off TCP Switching capacity Nominal current Voltage Marking Switching function max. 8 x I N 0.1 A – 10 A AC 250 V / DC 65 V Yes On & off switch incl. electric isolation TCP...

15 Masterversion 13 15 / Name / Department / Date Thermal Switch-off TCP-Applications Safeguarding of inductive loads FanMotorsHeating elements

16 Masterversion 13 16 / Name / Department / Date Thermal Switch-off TCP - comparison Switching capacity Nominal current Voltage Marking Switching function 150 A 5 A – 30 A DC 32 V No Can be switched back on again incl. electric isolation max. 8 x I N 0.1 A – 10 A AC 250 V / DC 65 V Yes On & off switch incl. electric isolation TCP...TCP.../DC32V

17 Masterversion 13 17 / Name / Department / Date Thermal Switch-off TCP/DC - Areas of applications Protection of DC board and battery systems Cars & TrucksShipbuildingIndustry

18 Masterversion 13 18 / Name / Department / Date Thermal Switch-off TCP – Socket und accessoires UK 6-FSI/CUK 4-FSI/C

19 Masterversion 13 19 / Name / Department / Date Circuit Breaker Thermomagnetic protection Thermal protection Electronic protection

20 Masterversion 13 20 / Name / Department / Date Thermal & magnetic Electronic Short CircuitApplication Overload Over- load Over- load, Short circuit Circuit Breaker - Shut-down behavior

21 Masterversion 13 21 / Name / Department / Date Magnetic Switch-off TMC - Comparison Switching capacity Nominal current Nominal voltage Shut-down behavior Approbation Width TMC... max. 800 A 0.2A...16A AC 250V / DC 65V Fast blow and normal UL 1077 12.5 mm max. 800 A 0,5A...16A AC 240V / DC 28V normal UL 1077 12,3 mm UT 6-TMC...

22 Masterversion 13 22 / Name / Department / Date Magnetic Switch-off TMCP Socket and Accessoires Fixed bridge pluggable FBST 500 TMCP Socket – 2-position TMCP Socket M Termination element TMCP Connect LR Signal bridge for free slots TMCP SB

23 Masterversion 13 23 / Name / Department / Date Device protection with system Thermomagnetic Circuit Breaker at the CLIPLINE complete Push-In-System

24 Masterversion 13 24 / Name / Department / Date Magnetic Switch-off TMC & TMCP-Applications IndustryPlant constructionMachine building Secondary protection for industrial systems

25 Masterversion 13 25 / Name / Department / Date Circuit Breaker Thermomagnetic protection Thermal protection Electronic protection

26 Masterversion 13 26 / Name / Department / Date Circuit Breaker - Shut-down behavior Thermal & magnetic Electronic Short CircuitApplication Overload Over- load Over- load, Short circuit Over- load, Short circuit Attenuation/Capacity 1.8 x I N

27 Masterversion 13 27 / Name / Department / Date Electronic Switch-off ECP - comparison Voltage Nominal current Current limiting Elec. Isolation Assembly ECP DC 24V 1A...10A 1.8 x IN Yes Pluggable on TMCP-Socket-M

28 Masterversion 13 28 / Name / Department / Date Voltage Nominal current Current limiting Elec. Isolation Assembly DC 24V 1A...10A 1.8 x IN Yes Pluggable on TMCP-Socket-M ECP ECP-E... DC 24V 1A...12A 1.8 x IN No Pluggable on TMCP-Socket-M Electronic Switch-off ECP - Comparison

29 Masterversion 13 29 / Name / Department / Date Electronic Switch-off ECP - Comparison Voltage Nominal current Current limiting Elec. Isolation Assembly DC 24V 1A...12A 1.8 x IN No Din-Rail mountable DC 24V 1A...10A 1.8 x IN Yes Pluggable on TMCP-Socket-M EC-E... ECP ECP-E... DC 24V 1A...12A 1.8 x IN No Pluggable on TMCP-Socket-M

30 Masterversion 13 30 / Name / Department / Date EC-EECP-EECP Productrange Circuit Breaker

31 Masterversion 13 31 / Name / Department / Date Electronic Switch-off EC(P) Applications Plant constructionMachine building24 VDC-circuits Controllable secondary protection with status signal

32 Masterversion 13 32 / Name / Department / Date AC-area change DC-area distribute Application

33 Masterversion 13 33 / Name / Department / Date Specific Characteristic The power is limited VS.

34 Masterversion 13 34 / Name / Department / Date How to define the circuit breaker? What is the load behavior? Transmission – how long is the wire? How much space is available? Specific Characteristic

35 Masterversion 13 35 / Name / Department / Date What is the loads behavior? MCBEC-E Resistance ohmic Capacities Induktiv loads A, B, C, D C, D B, C, D Specific Characteristic

36 Masterversion 13 36 / Name / Department / Date Cable Length NominalC, 6 A6A Short Cicuit Area>7-times1,8-times Trip Current>42 A~11 A Max. Resistance24V/42A= 0,57 Ohm24V/11A= 2,18 Ohm Length at 1,0mm²15 meter50 meter Length at 0,5mm²5 meter30 meter Length at 0,34mm²effects source20 meter MCBEC-E Transmission – How long is the wire?

37 Masterversion 13 37 / Name / Department / Date Assembly How much space is available? 62,5mm : 5pol = 12,5mm 175mm : 5pol = 35mm

38 Masterversion 13 38 / Name / Department / Date Technical parameter

39 Masterversion 13 39 / Name / Department / Date Distribution up to 63 A Technical parameter

40 Masterversion 13 40 / Name / Department / Date Group-signalling with plug-in bridges Technical parameter

41 Masterversion 13 41 / Name / Department / Date Technical parameter

42 Masterversion 13 42 / Name / Department / Date All at a glace Small and compact design Energy-saving by current limitation Secure on long wires Easy assembly by pluggable bridges Highest value at capacities Distribution up to 50 A