Chaney et al.’s funhaler study (2004)

Similar presentations


Presentation on theme: "Chaney et al.’s funhaler study (2004)"— Presentation transcript:

1

2 Chaney et al.’s funhaler study (2004)
Area: Developmental Theme: External influences on childrens behaviour The Funhaler is a paediatric small volume spacer that makes it easier for young children to take their asthma based medication. It is designed to improve compliance in asthmatic children through being both functional in delivering medication and fun to use due to an incentive module

3 Psychological literature
• Operant conditioning is a form of associative learning, whereby associations and connections are formed between stimuli and responses that didn’t exist before learning occurs. • Operant conditioning involves learning through the consequences of behavioural responses. Funhaler is based on the principle of positive reinforcement…

4 Background to the study
Poor adherence to the correct use of inhalers is major problem (Chaney et al, 2004). Rates of compliance for asthmatic children range from 30% to 70%. Although reasons for poor adherence are varied, Watt et al proposed that a positive interplay of adherence considerations with aerosol output factors would improve medication adherence in young asthmatics. The aim of this study was therefore to show that the use of a novel asthma spacer device, the “Funhaler”, which incorporates incentive toys isolated from the main inspiratory circuit by a valve, whilst not compromising drug delivery, can provide positive reinforcement which leads to improved adherence in young asthmatics.

5 Two inhalers 1… Breath-a-tech 2…. Funhaler Research method Field experiment Conducted in the participants’ home settings in Australia Repeated measures design. The independent variables (IVs) were: (i) whether the child used a standard/small volume spacer device – the Breath-a-Tech (Scott-Dibben, Australia) (ii) whether the child used a Funhaler (InfMed Ltd, Australia). The dependent variable (DV) was the amount of adherence to the prescribed medical regime. Self- report from parents on compliance

6 Sample 32 children (10 male, 22 female; age range years, mean age 3.2 years; average duration of asthma 2.2 years) prescribed drugs delivered by pMDI and spacer were recruited. The children’s parents provided informed consent and also participated in the study through completing questionnaires and taking part in a phone interview. They also helped (where necessary) in the use of the inhalers.

7 Procedure Step 1: A comparison was made between the aerosol output of the standard/small volume spacer device (235ml Breath-a-Tech) and the 225ml Funhaler. Overall no significant differences were observed. The comparison was therefore complementary, indicating that the use of a Funhaler rather than a standard inhaler does not compromise drug delivery Step 2: Participants were then asked to use a Funhaler instead of their normal pMDI and spacer inhaler to administer their medication. Questionnaires were competed (by parents) after sequential use of the Breath-a-Tech inhaler and the Funhaler. The first questionnaire was completed at the beginning of the research before the Funhaler had been used. After 2 weeks of using the Funhaler a second questionnaire was done.

8 Procedure Data collected from the self-report related to:
How easy each device was to use Compliance of parents and children Treatment attitudes. Furthermore, during the course of the study each parent was called at random to find out whether they had attempted to medicate their child the day before.

9 Procedure The Funhaler incorporates a number of features to distract the attention of children from the drug delivery event itself and to provide a means of self reinforcing the use of effective technique. The Funhaler makes spacers appealing to children in the following ways: It isolates incentive toys (e.g. spinner and whistle) in a separate branch to the standard inhalation circuit, placing them outside the expiratory valve of the spacer to avoid problems of contamination and interference of drug delivery. The inhaler is easy to use in the correct way. The design attempts to link the optimal function of the toys to the deep breathing pattern related to effective medication. Children may get bored of the toys. However, the design allows the incentive toy module to be replaced with a range of different toys.

10 Results The use of the Funhaler was associated with improved parental and child compliance. When surveyed at random, 38% more parents were found to have medicated their children the previous day when using the Funhaler, compared to their existing small volume spacer device (22/27 versus 16/27 respectively; p = 0.016). (parent compliance) 60% more children took the recommended four or more cycles per aerosol delivery (24/30 versus 15/30; p = 0.02) when using the Funhaler compared with the standard/small volume spacer. Significantly more parents reported they were ‘always’ successful in medicating their child using the Funhaler (22/30), compared to their existing device (3/30).

11 Conclusions Improved adherence, combined with effective delivery characteristics, suggest that the Funhaler may be useful for management of young asthmatics The use of the Funhaler could possibly be used to improve adherence The use of functional incentive devices such as the Funhaler may improve the health of children More research is recommended in the long-term effectiveness of the Funhaler