Replacement of Valve Prosthesis Within Aortic Composite Graft
Paul P. Urbanski, MD, PhD The Annals of Thoracic Surgery Volume 88, Issue 6, Pages (December 2009) DOI: /j.athoracsur Copyright © 2009 The Society of Thoracic Surgeons Terms and Conditions
2
Fig 1 Operative photographs showing: (A) the deteriorated stentless valve (SPV Toronto [St. Jude Medical Inc, St. Paul, MN]) inside the vascular tube (InterGard [InterVascular, La Ciotat, France]); and (B) removal of the valve prosthesis by cutting the suture between the valve and the tube; and (C) the valve view after its complete removal. The Annals of Thoracic Surgery , DOI: ( /j.athoracsur ) Copyright © 2009 The Society of Thoracic Surgeons Terms and Conditions
3
Fig 2 Operative photographs showing (A) the passing of the pledgeted sutures for valve fixation through the annulus, and (B) the location of the pericardial valve prosthesis (Carpentier Edwards Perimount Plus [Edwards Lifesciences, Irvine, CA]) inside the vascular tube (InterGard [InterVascular, La Ciotat, France]). The Annals of Thoracic Surgery , DOI: ( /j.athoracsur ) Copyright © 2009 The Society of Thoracic Surgeons Terms and Conditions