ENTER OUR FRIEND MR. RELAY
3
Material needed : Relay (120 VAC coil) Socket for relay Some wire Push button (optional) Indicator Light (optional - Available on some relays)
4
Always: LOCK - TAG & TEST BEFORE Starting any electrical work
5
To Supervisor L(101) N (102) R
8
To Supervisor L(101) N (102) R “Close” Circuit by momentarily ‘jumping from line to coil
11
To Supervisor L(101) N (102) R Push button option to close circuit
12
So with the red and white connected to power the relay’s coil remains de-energized
13
Until the pushbutton switch is closed or a jumper used
Push button option to close circuit
14
Once the relay coil is activated the relays N. O
Once the relay coil is activated the relays N.O. contacts close and the jumper should be removed or switch opened L(101) N (102) R
15
The relay will remained “LATCHED” until power is interrupted
The relay will remained “LATCHED” until power is interrupted. If power is lost the relay will de-energized and remain in that state. L(101) N (102) R Optional indicator light