Download presentation
Presentation is loading. Please wait.
Published byAlejandra Limer Modified over 10 years ago
1
Case Study - By Ameya Tandulkar
2
Facts LocationLondon, UK SectorResidential Dates2005 -2011 Total Area65,000m 2 Cost£500 million ClientProject Grande (Guernsey) Ltd The ArchitectRogers Stirk Harbour + Partners Structural EngineerOve Arup & Partners Services EngineerCundall Cost ConsultantGardiner & Theobald Project ManagerGVA Second London Wall Project Management Planning ConsultantDP9 Fire ConsultantExova Warrington Fire Landscape ArchitectGillespies Interior DesignCandy & Candy Interior ArchitectBFLS Public Lighting DesignJames Turrell Main ContractorLaing ORourke 11/4/20112
3
Aerial view of the site 11/4/20113
4
Location 11/4/20114
5
3D View 11/4/20115
6
3D View 11/4/20116
7
CONCEPT Concept 11/4/20117
8
The brief for One Hyde Park was for a landmark development which complements and enhances the rich textures of the existing local architecture, whilst creating a structure which integrates well with the neighbouring buildings. With the exception of the former Bowater House, one of the key consistent features was the expression of verticality, ranging from the bays of Mandarin Oriental Hotel to the verticality of the Hyde Park Barracks tower. The existing rooflines – a dynamic and prominent feature of the local context – are characterised by the cupolas, turrets, gables and chimney stacks of the adjacent Mandarin Oriental Hotel. Detailed analysis of the site context suggested that the buildings separating the Park from Knightsbridge were disjointed and disparate in height, style and composition, resulting in a varied architecture along the northern side of Knightsbridge. In recognition of the context – and in contrast to the design of Bowater House – a series of interlinked pavilions was conceived to allow permeability and offer views of Hyde Park from Knightsbridge. The separation of the pavilions was conceived to create a stronger visual connection between Knightsbridge and the Park than had previously existed.The separation of the pavilions was conceived to create a stronger visual connection between Knightsbridge and the Park than had previously existed. The relationship of the pavilions with each other and with neighbouring buildings follows a radial pattern emanating from a central point well within the Park. This has resulted in a complementary alignment with the immediately adjacent buildings of Wellington Court and Mandarin Oriental Hotel, as well as reinstating – as close as possible – the sweep of the original road and pavement alignment to Knightsbridge.This has resulted in a complementary alignment with the immediately adjacent buildings of Wellington Court and Mandarin Oriental Hotel, as well as reinstating – as close as possible – the sweep of the original road and pavement alignment to Knightsbridge. The shaping of the pavilions – which widen towards the centre of the site and taper towards the perimeter – allows for oblique lateral views from each pavilion towards Knightsbridge to the south and the Park to the north. The passenger cores are used by residents for primary access to the apartments and penthouses, and service cores are used for secondary access by staff and for providing service access to the apartments. These cores are intended to be as light and transparent as possible, to maximise visual connections between the Park and Knightsbridge.These cores are intended to be as light and transparent as possible, to maximise visual connections between the Park and Knightsbridge. 11/4/20118
9
Orientation 11/4/20119
10
Site permeability 11/4/201110
11
Residential Accommodation 11/4/201111
12
Definition of boundaries 11/4/201112
13
Definition of edges 11/4/201113
14
Daylight and sunlight relationships 11/4/201114
15
Views to Hyde Park and oblique views to Knightsbridge 11/4/201115
16
Relationship between 'served' and 'servant' spaces 11/4/201116
17
Massing diagram 11/4/201117
18
Proposed massing adjustment and existing grain analysis 11/4/201118
19
Canopy over Edinburgh Gate acts as a visual and acoustic barrier 11/4/201119
20
Landscape area within site constraints 11/4/201120
21
Diagram showing views and privacy screens 11/4/201121
22
Diagram showing aspect and views 11/4/201122
23
Ground floor public realm 11/4/201123
24
DESIGN 11/4/201124
25
Design The overall footprint of the redefined site has determined the width and length of the pavilions as well as the differences between each building and the width of the passenger cores and support service cores. This approach has helped to provide a continuity of the building edge to the new southern boundary of the site along Knightsbridge. The shaping of each pavilion maximises its perimeter, allowing all the principal rooms to be located at the northern and southern ends along the edges of the pavilions, providing panoramic views across London. Secondary rooms are located further along the perimeter towards the centre of the pavilions, offering controlled views northwards and southwards, with tertiary spaces (those not requiring natural daylight) accommodated within the central part of the floorplates. The geometry of the privacy screens and the shape of the pavilions have combined to generate many of the interior spaces. Views are controlled by the use of carefully positioned privacy screens placed externally to the façade. These screens prevent overlooking from one apartment to another. This also prevents overlooking between pavilions. A typical level façade system consists of triple glazing comprising an outer single pane, a ventilated cavity containing an interstitial vertical roller blind, and an inner double-glazed unit, all rigorously following the geometry of the pavilions. Views are controlled by the use of carefully positioned privacy screens placed externally to the façade. The narrow promontories at the north and south end of each pavilion are intended to form the leading edges of the development. This gives it a slender appearance on both the Hyde Park and Knightsbridge sides. The scale of the scheme is evident when seen in terms of its relationship to the bays and projections evident in the predominantly Victorian and Edwardian buildings which surround it.This gives it a slender appearance on both the Hyde Park and Knightsbridge sides. The pavilions are separated by highly transparent circulation cores comprising lobbies, stairwells and lift shafts and providing clarity between served and servant spaces. The pavilions vary in height, stepping up in increments of two storeys. The two-storey increments accord with the grain of the local context, providing scale, grain and legibility to the development and offering residents impressive views across London. The pavilions are separated by highly transparent circulation cores comprising lobbies, stairwells and lift shafts and providing clarity between served and servant spaces. Architectural expression and selection of materials reflect the division of each pavilion into three distinct zones: top, middle and base. This, in turn, references the prevalent vertical zoning found in other local buildings. Flat, neutral greys have been used at the top of the building, whilst red/brown patinated copper privacy screens are used in the middle, reflecting the predominant colouration of Knightsbridge. Lower levels are neutral, similar to the stone plinths of the surrounding buildings, recessed behind the structural columns of the exposed white concrete frame. 11/4/201125
26
Long elevation showing context of One Hyde Park 11/4/201126
27
North elevation 11/4/201127
28
Aerial view from Knightsbridge 11/4/201128
29
View from Knightsbridge 11/4/201129
30
View from Sloane Street 11/4/201130
31
Detailed bay 11/4/201131
32
Rendering perspectives showing cladding systems 11/4/201132
33
Detail model showing privacy screens and stairwell 11/4/201133
34
Detail model showing balconies 11/4/201134
35
CONSTRUCTION 11/4/201135
36
A top-down construction methodology was used which offered significant programme benefits by overlapping the construction processes above and below ground, allowing excavations and construction works below ground to take place under cover and the superstructure above ground to proceed in parallel. Below ground, four levels of basement, covering the entire site footprint, were excavated in two-tier sections, each six metres high. The intermediate levels were then inserted into these double-height spaces as necessary. The lower two levels have been primarily designated for residential stores and car and cycle parking, which are served by two car lifts from the entrance setting-down area. The upper two levels – comprising some double-height spaces – are occupied by residential and neighbouring Mandarin Oriental Hotel leisure facilities, central plant and the loading dock area, served by two truck lifts. Following the casting of the ground-floor slab, the superstructure works commenced in parallel with the excavation of the basements. Above ground, two levels of floor slabs were installed in approximately 16-day cycles – the two-storey perimeter pre-cast concrete columns being erected first, then the single storey in situ / pre-cast internal columns, prior to casting an intermediate level floor slab, then the next level of single-storey columns erected, followed by the next floor slab. Teams working in parallel on each of the four pavilions repeated this cycle. The delivery of the southern sections of Pavilions B and C was staggered, allowing the road realignment to be completed, at which point, these areas were progressed and rejoined the overall programme. The superstructure of all four pavilions took 14 months to construct.The superstructure of all four pavilions took 14 months to construct. For lateral stability to the pavilions, a total of 48, two-storey high, perimeter steel cross braces are used – in the north/south orientation – across the whole development. These help to free up internal space permitting flexibility to the apartment configurations. The external visible structural elements to the pavilions are made from pre-cast concrete – containing crushed limestone aggregate together with a high content of mica, to create a stone-like appearance with light-reflecting quality that heightens the whiteness of these elements. The core structures located in between the pavilions and at the ends, consist of steel components designed and engineered to bolt together. A mock-up of parts of an apartment was built in a warehouse in North London to give those working on the project a tangible view of the quality aspirations for the project as well as addressing buildability issues. This established the quality benchmark ensuring that quality control is maintained across all apartments within the development. One Hyde Park has adopted a collaborative approach, combining the skills and expertise of some of the best professionals in the architecture, art, design and construction industries. At the height of the project, more than 2,000 people were working on the construction site. 11/4/201136
37
Cross bracing 11/4/201137
38
Installation of cross bracing at the top levels of One Hyde Park 11/4/201138
39
Ground level works 11/4/201139
40
View from Harvey Nicholls during construction 11/4/201140
41
11/4/201141
42
11/4/201142
43
11/4/201143
44
11/4/201144
45
11/4/201145
46
11/4/201146
47
11/4/201147
48
11/4/201148
49
FLOOR PLAN 11/4/201149
50
11/4/2011 Case Study for Bombay Realty ( Business Development - Land) 50
51
VISUALS 11/4/201151
52
11/4/201152
53
11/4/201153
54
THANKS 11/4/201154
Similar presentations
© 2024 SlidePlayer.com. Inc.