1 HT-180 Handshake Tester for

2 HT-180 – Current Status Built on the technology of our 882 HDCP
compliance test feature – the worlds first and only commercially available HDCP Compliance Test application. Troubleshoots HDCP, HPD and EDID interoperability problems and helps identify problems. Provides both up-steam and down-stream views of HDMI component interactions. Enhanced localization features anticipated -- LCD display with error code reporting -- Save “Trace” Files

3 HT-180 – What does it do? Assists in the troubleshooting of HDMI
Interoperability and handshake problems Identifies 5V, Current and Hot Plug Issues Identifies EDID problems Localizes HDCP handshake problems

4 HT-180 – Typical root causes
EDID Failures -Checks if EDID port was not acknowledged -Checks if EDID port access was attempted by source -Verifies that EDID header and checksums are valid -Checks if EDID read was triggered by hot plug detection Hot Plug Failures -Checks hot plug for < 100ms deassertion -Verifies that hot plug downstream assertion is passed to upstream -Checks if hot plug detection assertion upstream was not the result of downstream problem -Measures +5v signals for voltage and current draw on a source HDCP Failures -Checks for invalid Aksv from source -Verifies that source write of An occurs prior to write of Aksv -Verifies that source read of Bcaps occurs prior to read of R0’ -Verifies that source write of Aksv occurs prior to read of R0’ -Checks for invalid Bksv from sink -Checks if Ri’ is read without second phase of authentication (in case of repeater) -Checks if HDCP reauthentication was triggered by hot plug detection -Checks if HDCP port is not acknowledged -Checks for excessive HDCP re-authentication attempts by source -Verifies that source attempted to access sink HDCP port -Checks if the READY bit is not set as a result of any of the following failure conditions: Repeater did not attempt to read Bksv downstream receiver Source did not begin reauthentication after five seconds Invalid Bksv

5 HT-180 – Operation HT-180 is inserted in an HDMI system. The product will test up to Three different devices for interoperability problems by displaying Error codes on the LCD as well as in HTML trace files.

6 HT-180 – Operation Set up a trace using Immediate evaluation on
displayed on the LCD Set up a trace using the trace file capture software Running on a connected PC

7 HT-180 – Operation Ticket No. Customer Info Products!! System Captured trace files allow system information to be sent to a lab for analysis. Each trace can specifically identify the components of the system tested, date and location.

8 HT-180 – Enhanced failure indication (DDC Protocol Traces)
Reason & action codes -Digests DDC protocol data -Provides root cause code -Documentation provides corrective action DDC protocol traces -USB captures DDC data -Customer service call card with documentation associates activity with DDC trace files

9 HT-180 – Enhanced failure indication (reason & action codes)
Error Codes are shown on the LCD, indicating more precise failure mode and referring to a list of causes as well as possible solutions. Additionally, an “A”, “B” or “C” rating can suggest Severity of the diagnosis.

10 HT-180 – Support Documentation HT-180 Error Code Reference Guide
Consultation (if necessary) DDC trace analysis

11 Current Reason Code Listings
NO_ERROR 0x00, EDID_HEADER_BAD 0x01, EDID_CHECKSUM_BAD 0x02, EDID_NOT_READ 0x03, EDID_READ_INCOMPLETE 0x04, EDID_READ_DURING_HPD_LOW 0x05, EDID_READ_NACKED_HPD_HI 0x06, LARGE_EDID_WITHOUT_EDDC 0x07, EDID_NOT_READ_AFTER_HPD 0x08, EDID_CROSSED_256_BYTES 0x09, AKSV_BAD 0x10, BKSV_BAD 0x11, FACSIMILE_AKSV 0x12, FACSIMILE_BKSV 0x13, HDCP_NOT_ATTEMPTED 0x14, HDCP_READ_DURING_HPD_LOW 0x15, HDCP_NACKED_HPD_HI 0x16, AKSV_WRITTEN_BEFORE_AN 0x17,

12 Current Reason Code Listings
AKSV_WRITTEN_WRONG_ORDER 0x18, AKSV_SENT_MULT_TIMES 0x19, HDCP_WENT_BEYOND_LENGTH 0x1A, KSV_FIFO_READ_INCOMPLETE 0x20, KSV_FIFO_READ_NOT_5_MULT 0x21, KSV_FIFO_HAD_BAD_KSV 0x22, KSV_FIFO_HAD_FACSIM_BKSV 0x23, KSV_FIFO_WITHOUT_BSTATUS 0x24, KSV_FIFO_READ_TOO_LONG 0x25, KSV_FIFO_MISSING_BKSV 0x26, KSV_FIFO_WITH_NO_DEVS 0x27, KSV_FIFO_WITH_NO_READY 0x28, R0_READ_WITHIN_100MS 0x30, R0_READ_BEFORE_BCAPS 0x31, R0_READ_WITHOUT_AKSV 0x32, R0_READ_BEFORE_BKSV 0x33, RI_MISMATCH_CAUSE_REAUTH 0x34, R0_MISMATCH_CAUSE_REAUTH 0x35,

13 Current Reason Code Listings
SOURCE_USES_SHORT_READS 0x36, BCAPS_RESERVED_BITS_SET 0x40, BCAPS_NOT_READY_IN_TIME 0x41, NO_REAUTH_AFTER_NO_READY 0x42, DS_FAIL_WITH_NO_HPD 0x43, BCAPS_NOT_POLLED 0x44, BCAPS_READY_CAUSE_REAUTH 0x45, BSTATUS_HAD_MAX_DEVS_EX 0x50, BSTATUS_HAD_MAX_CASC_EX 0x51, BSTATUS_RESERVED_SET 0x52, BSTATUS_NOT_HDMI_MODE 0x53, BSTATUS_HDMI_NO_BCAPS 0x54, BSTATUS_DEVS_0_WITH_DEV 0x55, BSTATUS_DEV_CNT_0_PROB 0x56, BSTATUS_MAX_STAT_NO_PASS 0x57, AINFO_1_1_SET_NO_BCAPS 0x60, AINFO_RESERVED_SET 0x61, AINFO_AFTER_AKSV 0x62,

14 Current Reason Code Listings
V_PRIME_WITH_NO_BSTATUS 0x64, V_PRIME_WITH_NO_READY 0x65, DOWNSTREAM_AUTH_NOT_UP 0x67, DOWNSTREAM_REAUTH_NOT_UP 0x68, REAUTH_CONSTANT 0x69, SOURCE_STOPS_POLLING_RI 0x6A, DDC_MISSING_STOPS 0x6C, DDC_MISSING_STARTS 0x6D, HPD_TOO_SHORT 0x70, HPD_NEVER_GOES_HIGH 0x71, HPD_NOT_PASSED_THROUGH 0x72, HPD_NOT_HIGH_AFTER_5_SEC 0x73, NO_REAUTH_AFTER_HPD 0x74, AUTH_CONTINUES_AFTER_HPD 0x75, VOLTAGE_TOO_LOW 0x78, VOLTAGE_TOO_HIGH 0x79, CURRENT_PULL_TOO_HIGH 0x7A

15 HT-180 Diagnosis & Study The HT-180 will provide a