Download presentation
Presentation is loading. Please wait.
1
Dual Floc Tube Water Treatment System
How to Use the Dual Floc Tube Water Treatment System Dual Floc Sock Housing Sock 2 Chitosan PTS Sock 1 DBP 2100 DBP-2100 Floc Sock 2 lbs. Specifications: Length: 72 Inches Width: 6 in. diameter Fabric: Knit fabric Natural Polymer: 2.0 lbs. (dry weight) Treatment: 200,000 1 mg/L Passive Treatment Sock 2-lb. Specifications: Length 72 Inches Width: 5 in. diameter Fabric: Woven polypropylene Chitosan: 2.0 lbs. (dry weight) Treatment: 200,000 1 mg/L Sound Environmental Concepts, LLC nd Woodinville, WA *
2
Engineered SEC Settling Basin Design
Side View Top View Dual Sock Housing Engineered SEC Settling Basin Design Crushed Rock Dam Discharge Structure
3
Stormwater Detention Basin Treatment
Biochar Filter Dual Sock Housing Dual Sock Housing Pump Stormwater Detention Basin Treatment
4
1-2 Chitosan Socks & 1 DBP-2100 Sock
FLOW RATE US GPM 100 200 300 400 500 600 700 800 TURBIDITY NTU 1250 1500 1750 2000 2250 2500 1000 750 250 1-2 Chitosan Socks & 1 DBP-2100 Sock 2-3 Chitosan Socks & 1.5 DBP-2100 Socks 3-4 Chitosan Socks & 2 DBP-2100 Socks 4+ Chitosan Socks & 2.5 DBP-2100 Socks Dual Floc Water Treatment System APPLICATION CURVE – TURBIDITY VS FLOW RATE pH Range Sound Environmental Concepts, LLC nd Ave SE Woodinville, WA *