1 Day 2 Training - Sales Foundation Fieldbus
Sept. 18, 2008 Foundation Fieldbus Process Networking (C)

2 Foundation Fieldbus Protocol
Supported by most Process Instrument Companies. Designed as the Digital Bus Replacement for the 4 to 20mA Standard Well Promoted in North America as the “Process Bus”

3 Foundation Fieldbus Levels
H1 is the Field Instrument Level (We will Focus on this Level) HSE is the Computer Control Interface Level - Standard based on Fast Ethernet (100 Mbits/sec) - Uses UDP and TCP on Transport Layer and IP on Network Layer - Uses Foundation Application and User Layers with Object Oriented Process Language

4 Foundation Field Bus Networks
HSE (High Speed Ethernet) General Purpose Area Hazardous Area H1

5 FF H1 Physical Layer Bus Power/Device 15mA to 25mA Typical
Bus Voltage Must Operate from 9 to 32VDC Cable Length 1,900 meters (6,234 ft) Total Drop (Spur) Length # of Devices Max Length to m to m 2 to m

6 FF Physical Layer Transmission Speed - 31.25 Kbits/sec
Topology Tree Trunk

7 FF Physical Layer Barrier Power Supply Terminator
May be used in Intrinsically Safe Applications Number of Devices Distance, Barrier, Device Dependent Standardized IEC Terminators should be used on the trunk at the end of each segment (Used to prevent distortion and signal loss)

8 Device Types Link Master Device Capable of becoming the Link Active Scheduler Basic Device Not capable of becoming the Link Active Scheduler

9 Link Active Scheduler Must have one per segment
May have one device on segment designated as backup Issues Compel Data message (Highest priority activity) - Sends message to device Device receives Compel Data message - Device then “publishes” its data - Other devices configured to receive the data (Called “subscribers) Maintains Live List Periodically sends Probe Node messages to addresses not on the Live List Broadcasts changes to all devices Issues Pass Token for unscheduled communication

10 User Layer - Blocks Resource Blocks Transducer Blocks Function Blocks

11 User Layer – Resource Blocks
Includes read-only information that helps define the device -Manufacturer Name Model Number Materials of Construction -Device Options There may also be configurable parameters (device dependent) -Mode (e.g., Automatic or Out of Service) - Security and access limiting features (e.g., write locks) - Alarm options

12 User Layer – Transducer Blocks
Interface to sensors used to measure variables Device calibration information Sensor data Configurable mode (Automatic or Out of Service) - To perform calibration routines, most devices require that the block is Out of Service

13 Field Device Configuration
Resource Block These Configure the Device Transducer Block RB TB FB Function Block To FF Master Fieldbus

14 FF Function Blocks 21 function blocks specified for basic and advanced process control Function Block Examples Symbol Analog Input AI Analog Output AO Bias B Control Selector CS Discrete Input DI Discrete Output DO Manual Loader DD Proportional/Derivative PD Proportional/Integral/Derivative PID Ratio RA May be executed in host or Field Device

15 Consumer Producer Access (Peer to Peer)
Positioner AI-PID-AO Loop PID IN AIN OUT BKCAL_IN OUT AOUT Level Transmiter CAS_IN BKCAL_OUT

16 Function Block Scheduling
AI FB Publish (CD) PID FB AO FB Unscheduled Start Time Offset (ms) Macrocycle (ms) Cyclic Functions Control Functions Acyclic Functions - Alarms and Events - Maintenance and Diagnostic Info. - Trend Information - Configuration & Downloads Exec. time (ms) Scheduled Function Block Execution (AI) Scheduled Communication (CD) Scheduled Function Block Execution (PID) Scheduled Function Block Execution (AO)

17 Function Block Execution
Control Processor PID120 Field Devices AO 120 PID 110 AO 110 AI 120 AI 120 Function Blocks Are Supported in Control Processor or Field Devices; The Choice Is Yours!!

18 Device Description Key element that enables interoperability
Used to describe: Standard block parameters Supplier unique parameters Allow any compliant host to interoperate these parameters Available from vendor or Fieldbus Foundation DDs for devices tested with Host System typically included in release

19 Wiring and Installation Savings
100% 100% 22% 27% 57% 50% 12% Engineering 22% Assembly 51% Before After 23% Hardware 0% 4 to 20 mA Foundation Fieldbus

20 Reduced Engineering Costs
After Before

21 Additional Savings with Foundation Fieldbus
Elimination of Instruments with Multivariable Monitoring from Single Insertion Enabled Instrument Diagnostics Reduced Building Infrastructure More Process Flexibility Greater Process Optimization

22 Fieldbus Host Systems (Masters)
Emerson DeltaV Honeywell Invensys Yokogawa Smar Allen Bradley Softing

23 StoneL FF Power Supplies
Meets IEC specifications 0.35 Amps of Power

24 StoneL FF Cable Designed for Use in Standard Process Applications
PLTC, ITC 18 AWG Shielded 100m or 300m lengths Also available in I.S. Blue

25 FF Drop Connectors Direct mount Protected & Passive Drop Connectors
Day 2 Training - Sales Sept. 18, 2008 FF Drop Connectors Direct mount Protected & Passive Drop Connectors - Drop Leg Fault Protection - Easy Wiring - Direct mount type for JM or in customer’s enclosure Disconnect Switch Tee - Drop Leg Fault Protection Standard - De-energize drop leg Quickly & Conveniently Process Networking (C)

26 Day 2 Training - Sales Sept. 18, 2008 FF Drop Connectors Passive Double Drop, (1-2) - Multi Drop, DIN (1-4, 1-6) Protected mA, Single Drop (1-1) Multi Drop, DIN (1-4, 1-6) Switched Protected mA, Single Drop (1-1) Multi Switched Drop, DIN (1-4, 1-6) Process Networking (C)

27 FF Drop Connectors New Din Rail mount Drop connector
Day 2 Training - Sales Sept. 18, 2008 FF Drop Connectors New Din Rail mount Drop connector - Six (6) Device Drops Passive Protected Switched - LED indicates - Bus Power - Drop Power - Drop Short Circuit - Drop Leg Fault Protection - Din Rail mount - De-energize individual drops Process Networking (C)

28 FF I/O Module (Bus Powered Outputs)
Day 2 Training - Technical Sept. 18, 2008 FF I/O Module (Bus Powered Outputs) 2 Discrete Inputs, DI (StoneL Solid State Sensors or Special Low Power Dry Contacts) * Power Available < 6.5VDC On Current is .045 mA 2 Discrete Outputs Power output is 6.5VDC Total Current Consumption is 16mA * Discrete Inputs are not galvanically isolated from FF, Optocouplers may be needed if input device is not local Process Networking (C)

29 FF I/O Module (Externally Powered Outputs)
Day 2 Training - Technical Sept. 18, 2008 FF I/O Module (Externally Powered Outputs) 2 Discrete Inputs, 2 DI * (StoneL Solid State Sensors or Special Low Power Dry Contacts) - Power Available < 6.5VDC - On Current is .045 mA 2 Discrete Outputs, 2 DO watts Power Combined or Individual - Auxiliary 24VDC Power 1 Analog (4-20mA) Input 1 AI bit resolution (0.1%) 1 Analog (4-20mA) Output 1 AO bit resolution (0.1%) Total Communication Current Consumption is 16mA * Discrete Inputs are not galvanically isolated from FF, Optocouplers may be needed if input device is not local Process Networking (C)

30 FF Relay Module (Externally Powered)
Day 2 Training - Technical Sept. 18, 2008 FF Relay Module (Externally Powered) 2 DI same as I/O Module 1 AI & 1 AO same as I/O 2 Relay Outputs - Fused for 125/250VAC - Interlocking Independent Total Communication Current Consumption is 16mA Process Networking (C)

31 Day 2 Training - Technical
Sept. 18, 2008 StoneL FF VCTs Configuration - 2 Discrete Inputs (Solid State Sensing) - 2 Discrete Outputs with 4 Watt Maximum (Externally Powered “94”) OR 2 Discrete Outputs for Piezo Valving (Bus Powered “93”) - Current Consumption under 16mA Special Features - Watchdog Function (Predetermined Output Communication Fail State) Process Networking (C)

32 StoneL FF vs the Competition
JM I/O Smar I/O Turck Megablock StoneL FB Drop Connectors Relcom Connector Blocks StoneL DIN Drop Connectors

33 Optimal Applications When Using Process Control Loop Applications Utilizing Analog Functions When Information from Control Elements is Critical When Control in the Field is Desired In IS Applications Discrete Applications Using FF Lower number of Discrete Inputs interspersed with Analog Control Instruments Extremely Long runs of Discrete Inputs IS Applications

34 Network Layout and Design
Determine # of devices per segment Determine cable length and cable routing Determine Drop connector method Select FF power supply or power conditioner Size network based upon current load and network traffic time

35 Device Configuration www.stonel.com
Often done via FF host interface (Master) National Instruments Configurator with PCMCIA Host - Good for Bench testing and network configuration planning

36 Application Questions
Where can protected drop connectors be used? Can you use a conventional 24VDC power supply to supply the FF segment? StoneL offers short circuit protection devices for FF, At what current do they trip? What type of pneumatic valve can be used with bus powered Foundation Fieldbus Dual Modules?

37 Foundation Fieldbus