Flow Schematics – Air Terminal Chilled

Similar presentations


Presentation on theme: "Flow Schematics – Air Terminal Chilled"— Presentation transcript:

1 Flow Schematics – Air Terminal Chilled
QUALITY AIR DISTRIBUTION PRODUCTS Air Terminal Induction Chilled Beam Flow Schematics – Air Terminal Chilled

2 QUALITY AIR DISTRIBUTION PRODUCTS CFD of a ceiling model

3 EB AIR- Terminal Induction Models
QUALITY AIR DISTRIBUTION PRODUCTS Air Terminal Induction Chilled Beam 2 WAYS THROW- 1X4 –BOTTOM VIEW 2 WAYS (2X2) THROW 2 WAYS (2X2) THROW-TOP VIEW 1 WAY THROW-1X4 TOP VIEW 1 WAY THROW (2X2) –BOTTOM VIEW 1 WAY THROW-1X4 –BOTTOM VIEW

4 QUALITY AIR DISTRIBUTION PRODUCTS Air Terminal Induction Chilled Beam
Actual units for projects

5 QUALITY AIR DISTRIBUTION PRODUCTS Air Terminal Induction Chilled Beam
High Capacity Units ( Single+ Double units) Single ATCBU Double ATCBU Double ATCBU

6 QUALITY AIR DISTRIBUTION PRODUCTS Air Terminal Induction Chilled Beam
EVOLUTION From Induction unit – the idea developed Ceiling mounting for better coverage High capacity to bigger loads No Moving parts/ No Maintenance Low Noise Aerodynamic Nozzles and better Induction All packaged in a compact box

7 QUALITY AIR DISTRIBUTION PRODUCTS Air Terminal Induction Chilled Beam
When not draining the pan, float switch sends signal to CCD controller to shut the water valve so no more water entering the coil, if ½” or more condensate collects on drain pan.

8 QUALITY AIR DISTRIBUTION PRODUCTS Induction Unit
Induction unit (Type ML) High Capacity Induction Unit (Type HVMG)

9 QUALITY AIR DISTRIBUTION PRODUCTS Induction Unit
Used in retrofit application and new building designs Basic Models : Low Boy ML and MG, Available in various heights 11.42”, 22.87”,17.38” . Four basic sizes model ” length , model ” length, model ” length, model ” length 2pipe ( 1 Row, 2 Row) & 4 Pipe coil configurations available to meet various loads Low primary air pressure design with extremely low noise due to efficient nozzle configuration Higher Induction Ratio’s ( 2.4 to 5.5) can be achieved at lower primary air pressure

10 QUALITY AIR DISTRIBUTION PRODUCTS Test of Induction unit performance
Unit Measurement using various probes Air Velocity + Total Air

11 QUALITY AIR DISTRIBUTION PRODUCTS Induction Unit
Test set up at ETL Lab Various tests were carried out both on Induction unit and ceiling Induction Chilled Beam to validate performance of capacity, throw and noise. We tested several models to highlight performance on conditions as required on different projects.

12 QUALITY AIR DISTRIBUTION PRODUCTS Induction Unit
Low Boy(Type ML) Tall Boy Induction Unit (Type MG) Horizontal Bulkhead Induction (Type HMG)

13 Field installations

14 QUALITY AIR DISTRIBUTION PRODUCTS
Active Chilled Beam