Presentation is loading. Please wait.

Presentation is loading. Please wait.

FRA Measurements for Power Electronics

Similar presentations


Presentation on theme: "FRA Measurements for Power Electronics"— Presentation transcript:

1 FRA Measurements for Power Electronics
January 28th, 2019 Steve Sandler

2 Primarily focused on RF, Analog, and Distributed Power Systems
40+ Years Experience (1977-present) AEi Systems – Founder and CTO (1995-) Picotest – Founder and Managing Director (2010-) Test Engineer of the Year ( ) Experience: Space Shuttle, Space Station, GPS, Large Hadron Collider and many other military and commercial projects Primarily focused on RF, Analog, and Distributed Power Systems I enjoy writing lecturing lab time and making pizza

3 The FRA measurements FRA Analysis Control Loop PSRR/PSMR

4 Control loop Measurement

5 Power Supply Rejection/Modulation Ratio
PSRR/PSMR

6 $ Targeting Customers $ Components Digital Design Power Designers
AC/DC DC/DC Silver box Components IC Manufacturers TI, Analog Devices, Xilinx, ON Semi Digital Design FPGA, DDR, Clocks VRM/PCB Design EMC, Intel RF & Microwave Amplifiers, Sensors Microsemi / Symmetricom Here you will overview the key markets, market segments, types of customers and applications. Place pictures representing each market on the slide. $ $

7 The Most Basic Scope FRA Bundle
J2100A Injection transformer J2120A Line injector VRTS 1.6 Demo Board

8 The J2120A Line Injector ~ 1𝑢𝑉 𝐻𝑧 ~1𝑚𝑉𝑝𝑝 ~ 350𝑛𝑉 𝐻𝑧 ~200𝑢𝑉𝑝𝑝
~ 1𝑢𝑉 𝐻𝑧 ~1𝑚𝑉𝑝𝑝 ~ 350𝑛𝑉 𝐻𝑧 ~200𝑢𝑉𝑝𝑝 ULTRA-LOW noise Up to 50VDC 5Amps CE Certified ~ 1𝑛𝑉 𝐻𝑧 ~2𝑢𝑉𝑝𝑝 Need higher voltage or current? J2121A 400VDC/20A

9 The J2100A and J2101A Transformer
High linearity/low distortion Up to 600V Cat II CE Certified Need higher bandwidth, lower frequency? J2110A DC-100MHz 10V injector

10 Common measurement errors?
The results can become distorted if the injected signal is too large May need to remove many or most of the input capacitors The scope has limited dynamic range. The demo boards are designed to stay inside this range. Going outside the range can result in bad data Induced noise in ground leads can be significant – plug for the mmcx tips works here

11 Demonstrating the FRA features
Control the setting by using your own demo boards and knowing the right answer Start with the VRTS1.6 to show off mmcx probe tips. Some customers will complain that VRTS1.6 is a linear regulator – too easy LM20143 is pocket sized, USB powered control loop demo switching regulator VRTS3 is more sophisticated, USB powered, switching regulator and PSMR LM20143 VRTS3

12 Picotest products and expertise are available to you and your customers
Visit Visit Hands-on workshops at +1 (480) Connect with me on LinkedIn Join the Power Integrity for Distributed Systems Linkedin Group Sign-up for the Picotest monthly newsletter

13 Thank you for attending this session!
Call to Action! Thank you for attending this session! Search for these opportunities at the highest level possible Use Picotest as your consultant. We can answer questions you can’t and potentially boost margin Encourage customer training – Educated customers spend more and most attendees do purchase These measurements are a stepping stone to Power Integrity. Power Integrity has much more $$$ to spend


Download ppt "FRA Measurements for Power Electronics"

Similar presentations


Ads by Google