Gdpack 40.5kV Technical Data Sheet MV-LV Prefabricated Substation

Similar presentations


Presentation on theme: "Gdpack 40.5kV Technical Data Sheet MV-LV Prefabricated Substation"— Presentation transcript:

1 Gdpack 40.5kV Technical Data Sheet MV-LV Prefabricated Substation
Steel Housing Primary Voltage: up to 40.5kV Power Rating: up to 3500 kVA Technical Data Sheet

2 GDpack Primary Voltage: 40.5kV Definition
Power Rating: Up to 3500 kVA GDpack Definition GDpack is a type tested MV/LV prefabricated substation comprising of an enclosure containing Medium Voltage switchgear, Distribution transformers, Low Voltage switchboards, connections and auxiliary equipment to transform energy from medium to low voltage systems. Layout Features Type tested per latest GB Internal Arc fault Type AB tested at 20 kA, 1second High level of safety for equipment and personnel All equipment inside GDpack are type tested Engineered footprint meeting required clearance standards Optional oil collection pit underneath the transformer Steel housing Can be delivered with transformer installed Engineered for smooth air flow and natural cooling Locking system for all doors to prevent un-authorized entry of personnel Stainless steel hinges for corrosion resistance No access to live parts Equipment Description Transformer GDpack is designed and manufactured to accept oil or dry transformers. Medium Voltage GDpack can be provided with different options of Medium Voltage kV Switchgear from our SF6 insulated compact secondary switchgear portfolio. Low Voltage The LV compartment could accommodate an LV panel with ACB or MCCB’s and various number and ratings of outgoing feeders depending on transformer size and customer needs. Special low voltage equipment is available upon request.

3 GDpack Primary Voltage: 40.5kV Additional equipment
Power Rating: Up to 3500 kVA GDpack Additional equipment Devices for metering and control circuit SCADA ready for easy connection to any SCADA System through standard communication protocols. Power Factor Correction Panel Remote Terminal Unit (RTU) to monitor the CSS and store data for operation, maintenance and fault analysis. Local and remote monitoring operations available. Standard Models Model Number Max. KVA kV Maximum Number of MV Switchgear panels MV Switchgear Insulation Type GDpack 20NS 2000 12, 24, 36 & 40.5 Up to 4 Gas GDpack 35NS 3500 Installation Factory delivers a factory tested solution to the installation site, and provides all necessary lifting device for moving the substation. No complicated civil engineering job is needed in advance or during the installation. Only a pit has to be excavated and the substation has to be placed into this installation pit. When the substation is in its place, than the commissioning can be started after the incoming and outgoing cables had been connected. For detailed information please see our installation manual.

4 GDpack Primary Voltage: Up to 40.5kV Technical Data Description
Power Rating: Up to 3500 kVA GDpack Technical Data Description UniPack Compact Secondary Substation – Mercury layout Max KVA 2000 3500 Type of layout Mercury 20NS Mercury 35NS Rated voltage (kV) 12/24/36/40.5 kV Short circuit withstand current of internal earthing network 6kA/1s, upon request 20kA/1s Substation dimension (with Gas insulated MV swgr. -LxWxH) in mm. 3450x2450x2750 4400x2450x3050 Weight of substation excluding transformer (approx.) in kg. 2700 3200 Transformer compartment dimension (LxWxH) in mm 2400x1800x2400 2850x2400x2700 Maximum transformer load losses/ No load losses in watts 14300/2500 30000/4000 Transformer compartment IP protection degree (min/max) IP 23D / IP 33D MV/LV IP compartment protection (min/max) IP 23 / IP 54 CSS Enclosure Thermal class (min/max) 20K / 10K Maximum dimension of MV compartment 4-way SafeRing / SafePlus 40.5kV Maximum dimension of LV compartment 10 pcs of 630A MCCB MV cabling The connecting can be AL or CU acoording to customer request. If not specified then the cross section is selected to fulfill the short circuit requirement of the arrangement. MV terminations The connecting cables can terminated with premolded/cold shrink/heat shrink cable terminations according to customer’s request LV connection to transformer Cable or busbar according to the rated power of the transformer Rated current of LV panel, A Rated short circuit withstand capacity of LV Busbar system, kA/1s 50 kA/1s All information subject to change without notification Technical Data Sheet Number: DS.CSS.S.M_03