Download presentation
Presentation is loading. Please wait.
1
energy revenue & power quality meter
PowerLogic ION8800 energy revenue & power quality meter
2
A PowerLogic system can help you…
Lower operations costs automated, accurate billing data acquisition lowers administrative costs and eliminates errors while making the data available to regulators, service providers, and end users. Improve network reliability sophisticated power quality monitoring and reporting provide the information needed to validate compliance, improve system stability, and minimize unplanned downtime. Streamline business planning detailed information on loading, capacity, stress, and more, remove the guesswork so you can more efficiently coordinate demand-side management programs and optimize capacity planning.
3
The most advanced meter available
The ION8800 energy and power quality meter is the newest high-end meter in the industry-leading family of PowerLogic products Designed for tariff metering and power quality monitoring in IEC markets Typically applied at interconnection points on medium, high, and ultra-high voltage networks
4
A modular design Retrofit compatible with IEC/DIN ” rack mount series Tailor the meter to the application with numerous I/O options Solid-state Form A and Form C digital outputs Mechanical alarm relay High and low voltage digital inputs 3 base-model feature sets ION8800C - Basic tariff/energy revenue meter with sag/swell monitoring ION8800B – ION8800C + EN50160 compliance monitoring ION8800A – ION8800B + waveform capture and transient detection
5
Flexible multi-port communications
Standard IEC1107 optical port Communication module options include 1 RS-485/RS RS-485 serial ports Ethernet (10Base-T) or Fibre (10Base-FL) EtherGate: daisy-chain 31 devices to RS-485 Alarm notification via On-board web server with customizable web pages Modem (56 kbps) ModemGate: daisy-chain 31 devices to RS-485 Simultaneous communication on all ports Rear view of ION8800 meter picturing Essailec connector and communication module.
6
Energy and power quality metering in one
The ION8800 meets IEC Class 0.2S, the most stringent metering standard Measure power quality parameters according to IEC Class A, perform power quality compliance monitoring in accordance with EN standards, and measure flicker & interharmonics according to IEC & IEC Multi-user, multi-level security allows 16 designated users to gain access to the meter with security levels ranging from read access up to administrative rights
7
Meter characteristics (front panel)
Graphical LCD device setup & operational screens Menu control & demand reset buttons LEDs for alarm, heartbeat, and energy Sturdy handles for easy racking IEC1107 optical ports for energy pulsing SCADA (ION, DNP 3.0, DLMS, Modbus) Anti-tamper (revenue) lock
8
Meter characteristics (rear connections)
Voltage inputs and Digital I/O Modem (RJ11) port Serial ports (RS-232 and RS-485) Ethernet (TCP/IP) IEC/DIN 48362 Field-upgradeable Communication module Current inputs
9
Feature summary Power Quality ION8800A ION8800B ION8800C
Sag/swell monitoring g Symmetrical component: zero, positive, negative Harmonics: individual, even, odd, total (up to 63rd) Harmonics: magnitude, phase and interharmonics - EN50160 compliance monitoring Flicker (IEC ) Configurable for IEEE , IEEE Transient detection Waveform capture
10
Feature summary (cont.)
Communications & Logging/Recording ION8800A ION8800B ION8800C Modbus TCP master / slave (Ethernet) g / g - / g Modbus RTU master / slave (serial ports) Historical logs, maximum number of channels 800 640 32 Waveform logs, maximum number of channels 96 - Consecutive waveform cycles captured per MB 900 Revenue Metering & Standards IEC class 0,2S compliant g Time-of-Use Transformer/line loss compensation MV-90 on serial, modem, and Ethernet ports (if present)
11
Feature summary (cont.)
Communications and I/O All models IEC1107 optical port (COM1) - standard in front of meter 1 RS-485 port (COM2) - selectable on Essailec connector or communications module RS-232/485 port (COM3) - optional on communications module Internal PSTN modem (COM4) - optional on communications module Ethernet port - optional on communications module DLMS, DNP 3.0 & Modbus RTU Slave via serial, modem & optical port g Modbus TCP through Ethernet port EtherGate, Webmeter, ModemGate, features IEC1107 Active/reactive visible LED energy optical pulse ports Digital pulse outputs (solid state Form A) (Optional) 8 Digital pulse outputs (solid state Form C) 4 Alarm relay output (Form C) Digital inputs (Optional) 3
12
Feature summary (cont.)
Setpoints, Alarming, and Control All models Number of setpoints 65 Minimum response time for setpoints ½ cycle Math, logic, trig, log, linearization formulas g Call out on single condition & multiple condition alarms Logging and Recording Memory capacity (standard / optional) 5MB /10MB Maximum data points per MB (channels x depth per recorder) 165,000 Timestamp resolution in seconds 0.001 Min/max logging for any parameter GPS time synchronization (standard on serial; optional on IRIG-B) Power line time synchronization
13
Application: network revenue metering
Metering at generation, transmission, or distribution locations requires: Highest standards of accuracy Multiple communications ports Multiple protocols Security Compensation algorithms Billing system compatibility Power quality monitoring Web capabilities
14
Application: network revenue metering
The ION8800 meets and exceeds network revenue metering requirements: IEC class 0,2S accuracy Ethernet, modem, and serial communications ION, Modbus and DLMS protocols Multi-user, multi-level security as well as anti-tamper seals on the meter Instrument transformer correction and Transformer/line loss calculation capabilities MV-90 compatibility on serial, modem, and Ethernet communications
15
Application: power quality monitoring
EN50160 compliance reporting Analyze/troubleshoot based on IEC Class A Flicker to IEC ; harmonics/interharmonics to CEI Digital fault recording at 1024 samples/cycle 17/20µs (60/50Hz) transient detection and capture
16
Application: engineering and operations
The ION8800 integrates with SCADA software and supports substation automation: Feeder monitor aggregation and other PLC/RTU features within the substation Ethernet, modem, and serial communications ION, DNP 3.0, Modbus RTU master/slave, and Modbus TCP master/slave protocols WebMeter (onboard web server) and
17
The PowerLogic family Schneider Electric is the world’s largest provider of energy efficiency, power quality and reliability solutions PowerLogic offers enhanced, compatible and expanding breadth of capabilities and support Customers can leverage existing PowerLogic and ION investments and buy new PowerLogic products with confidence Compatible and expanding breadth of capabilities and support
18
For more information, visit powerlogic.com
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.