1 Dose in 2 - 10l/h clean liquid
Slurry Design Basic principle of handling solids : pump and motor are separated motor is filled with clean liquid During operation clean liquid approx. 2-10l/h will be dosed in motor circulation => volume of dosed in clean liquid will flow from motor to pump => particles or liquid from pump cannot enter into motor Heat exchanger Dose in l/h clean liquid

2 Handling Solids with Slurry design
pump and motor are separated motor is filled with clean liquid During operation clean liquid approx. 4-6l/h will be dosed in motor circulation => volume of dosed in clean liquid will flow from motor to pump => particles or liquid from pump cannot enter into motor Dosing pump, 4-6l/h

3 Slurry Design / CNK type with dosing pump for dose in clean liquid in motor end