1 Field Emission onset data from VTA testing of C50 pairs
Liang Zhao 09/09/2016

2 How were data acquired Collect all data from traveler
Double check original data and compare with traveler Definition of FE onset and value First point rising above noise level on Radiation-Eacc curve FE processed away are counted FE towards/at quench are counted Showing only final test result of qualified cavities Horizontal axis is along cavity test sequence, equivalent to timeline Emax is directly from traveler

3 Here FE onset at zero = no FE.
Year 2006 2007 2008 2009 2013 2014 2016 # of points 9 27 22 16 1 8 Summary of final test and qualified C50 cavities in VTA. Each point is a VTA test performed. Most of these cavities were build into pairs. Here FE onset at zero = no FE.

4 # of pairs need VTA re-test # of VTA tests to qualify pair
VTA re-tests to qualify cavity pair (preliminary analysis) Year # of pairs qualified # of pairs need VTA re-test # of VTA tests to qualify pair 2006 4 2.5 2,2,2 2007 16 2,2,2,3 2008 12 2,2,2,2 2009 8 2 3,2 2013 2016 2,2 1 CM = 4 pairs = 8 cavities