1 Be Off The Grid.com US Department of Energy ….2009 on LED Technology US Department of Energy ….2009 on LED Technology "No other lighting technology offers our nation so much potential to save energy and enhance the quality of our building environments. Healing the Earth – one light at a time

2 CO2 EMISSIONS BY LIGHT SOURCE

3 Global warming is the most pressing environmental issue of this century. What does this have to do with how we choose the way we light up our world? US government statistics- power plants in the US produced 2,459,000,000 tons of carbon dioxide (CO2) in 2006. Almost 32% of the electricity they generated was used for lighting. Get serious about fighting global warming… Make lifestyle choices that will reduce our greenhouse gas emissions. Most significant thing you can do…simple as L.E.D. Replace traditional lights* with an LED lights Reduce our carbon dioxide emissions by 27.4 million metric tons of CO2 per year! 3 x more carbon dioxide than Costa Rica gives off in whole year.** Global Warming

4 LEDs contain NO Mercury - Florescent Lights Do LEDs contain NO Mercury - Florescent Lights Do 49% of the electricity in the US is produced from coal fired power plants. Besides CO2, power plants emit hazardous substances including: Mercury, Nitrous Oxides, Sculpture Oxides, and others. LEDs for lighting = 80% less electricity = 80% less substances contaminating our environment = 80% less contact with us. LEDs last 60 x longer than incandescent lights and 10 x longer than fluorescent lights = less waste = less replacements. LEDs dont waste energy as heat = electricity you use for air conditioning inside. * All data and statistics are derived from publicly available data from the source for official energy statistics from the US government.

5 LED Lamp Features Ecology Ecology – Reduces Global Warming. Economy Economy – 80 + % less power consumption than traditional lights. Extended Life Extended Life -Rated at 50,000 hours which translates to 10 + years maintenance-free product life. Eliminates Eliminates - Glare, and night blossoming outside… Stops light pollution! Excellent Luminosity Excellent Luminosity -Ultra bright, cool white light close to daylight quality, provides bright white light which improves color rendering and improves night visibility to 300% over traditional light sources. Cost Saving Cost Saving -Save up to $280 per year per light, -2,300 over the products lifetime. GHG (Co2) Reduction GHG (Co2) Reduction - 768.2 lbs/yr; 10,574 lbs over the lifetime - as much Co2 as the average passenger car produces in 11 months of driving. *( - 768.2 lbs/yr; 10,574 lbs over the lifetime - as much Co2 as the average passenger car produces in 11 months of driving. *(Based on 1.55 lbs Co2 per kwh, 11,560 lbs Co2 per passenger car per year) Easy Installation Modular construction and mounting. – Modular construction and mounting.

6 Exterior LED Lamp/Bulb Vs High Pressure Sodium High Pressure Sodium LED Lamp Applications Major Roadways & Residential Streets Parking Lots Docks and Pliers Tennis Courts – Indoor Sporting Areas

7 Exterior LED Lamp/Bulb Vs High Pressure Sodium/Metal Halide A – LED Street Light no glare, close to daylight B – Metal Halide Street Light – Strong glare, high color temperature with harsh radiation levels C – Sodium Street Lamp – strong glare, very low color temperature producing untrue yellow and orange radiation effects

8 Exterior LED Lamp/Bulb Vs Metal Halide 120 Watts LED Street Light – LED Consumption 133 watt, power consumption 20 watts, power factory 0.98 Total Power Consumption : 155W The bean pattern is rectangular 26 x10 meters. Maximum intensity is 42 Lux and average intensity of 30 Lux Traditional 250 Watts Metal Halide Lamp Lamp power 285 watts, rectifier 23 watts Power factor : 0.5 Total Power Consumption 616 watts Brightness is significantly less than LED lamp Maximum intensity 35 lux and average intensity of 15 lux. The beam pattern is oval and undefined

9 Products SP90 - SP90 - 2,100lm (equal to 75w HPS Lamp on 7m height pole or 150w HPS lamp on 6m Height Pole UL2 = 250W HPS and 150W HPS LU 4 – 4 Panel LED Lamp 120w Comparable to: 250W HPS UL 6 – 6 Panel LED Lamp 225w Comparable to: 800W Metal Halide 800w Double Soduim & 400w HPS UL 8 – 8 Panel LED Lamp 225w Comparable to: 800 w Double Sodium and 800w Metal Halide UL1 = 500W Metal Halide Lamp

10 LU Street Light Installations

11 Easy Installation

12 Exterior LED Lamp/Bulb Vs Traditional High Pressure Sodium TypeHigh Pressure SodiumLED 1Unit250-300w120w 2Power ConsumptionHigh 100%Very low 10-15 % 3Energy SavingNoYes, 80+% 4Lighting Quality Yellow and OrangeClose to daylight (pure white) 5Safety Concern Light pollution Glare for driver's eyes Close to daylight quality, rendering of colors and higher real and effective almost zero 6Life Time of Bulb 6-8,000 Hours (1-2 years, base on 10 hours/day) 50,000 hours + 7Maintenance CostHigh (change bulb by every 1-2 years)Low 8 Power Supply System Stabilization NO. Surges Needs of 3 times the electric power at turn- on…and if the power supply is not stable it will cause damage or reduce the life to less than 1-2 years. Yes Digital No Surges Constant low power consumption at turn-on….and all the time. 9 Power Support Facilities like wires, HP transformers… 100%40% 10UV EmissionYesNo 11Operating TemperatureHot LightCool Light Few hundred degrees<50 degrees 12Environmental ProtectionNO YES, Less Pollution no CO2s

13 YEARS1st Year2 nd Year3 rd Year4 th Year5 th Year6 th Year7 th Year LED Lamp Cost $ 1,000.00 35% Electric+ 4% Electric Electric $ 34.23 $ 46.21 $ 48.05 $ 49.98 $ 51.98 Totals $ 1,034.23 $ 46.21 $ 48.05 $ 49.98 $ 51.98 Cumulative Costs $ 1,034.23 $ 1,080.44$ 1128.49 $ 1176.54 $ 1226.52 $ 1,276.50 $ 1,328.47 METAL HALIDE Lamp Cost $ 11.07 Electric $ 134.61 $ 181.72 $ 188.99 $ 196.55 $ 204.41 Labor Replacement $ 50.00 Ballast $ 96.00 Labor Replacement $ 75.00 $ 83.00 Totals $ 145.68 $ 231.72 $ 371.06 $ 238.99 $ 257.62 $ 375.55 $ 215.48 Cumulative Costs $ 145.68 $ 377.72 $ 748.48 $ 987.45 $ 1,245.07 $ 1,620.62 $ 1,836.10 High Pres. Sodium Lamp $ 9.07 $ 9.70 Electric $ 127.61 $ 172.27 $ 179.16 $ 186.33 $ 193.78 Labor Replacement $ 50.00 Ballast $ 96.00 Labor Replacement $ 75.00 $ 83.00 Totals $ 136.68 $ 172.27 $ 350.16 $ 179.16 $ 246.03 $ 365.33 $ 193.78 Cumulative Costs$ 136.68 $ 309.40 $ 309.40 $ 659.56 $ 838.72 $ 1,084.75 $ 1,450.08 $ 1,643.86 Costs and Savings Mercury Vapor Lamps are no longer allowed to be utilized in the United States - must be replaced with NON-MERCURY BULBS

14 High Pressure YEAR LEDMetal Halide Sodium 1 $ 1,034.22 $ 145.68 $ 136.68 2 $ 46.21 $ 231.72 $ 172.72 3 $ 48.05 $ 371.06 $ 350.16 4 $ 48.05 $ 238.99 $ 179.16 5 $ 49.98 * $ 257.62 * $ 246.03 6 $ 49.98 $ 375.55 $ 365.33 7 $ 51.98 $ 215.48 $ 193.78 8 $ 51.98 $ 254.41 $ 253.48 9 $ 54.06 $ 429.65 $ 407.53 10 $ 54.06 $ 262.58 $ 201.53 11 $ 56.22 $ 232.16 $ 209.59 12 $ 56.22 $ 488.09 $ 485.66 13 $ 58.47 $ 240.10 $ 217.98 Total $ 1,659.48 $ 3,743.09 $ 3,419.63 LED COSTS- $(1,659.48) $(1,659.48) SAVINGS- $ 2,083.61 $ 1,,760.15 (* Return on Investment) EACH LAMP OPERATIONAL COST ANALYSIS 250W EQUIVALENT LIGHTING LIFE OF LED LAMP (50,000 Hours)

15 YEARLEDMetal HalideHigh Pressure Sodium Initial Outlay Budgeted Dollars Year One $ 1,034.22 $ 145.68 $ 136.68 2 yr Cumulative $ 1,080.43 $ 377.40 $ 309.40 3 yr Cumulative $ 1,128.48 $ 748.46 $ 659.56 4 yr Cumulative $ 1,176.53 $ 987.45 $ 838.72 5 yr Cumulative $ 1,226.51 $ 1,245.07 $ 1,084.75 6 yr Cumulative $ 1,276.49 $ 1,620.62 $ 1,450.08 7 yr Cumulative $ 1,328.47 $ 1,836.10 $ 1,643.86 8 yr Cumulative $ 1,380.45 $ 2,090.51 $ 1,897.34 9 yr Cumulative $ 1,434.51 $ 2,520.16 $ 2,304.87 10 yr Cumulative $ 1,488.57 $ 2,782.74 $ 2,506.40 11 yr Cumulative $ 1,544.79 $ 3,014.90 $ 2,715.99 12 yr Cumulative $ 1,601.01 $ 3,502.99 $ 3,201.65 13 yr Cumulative $ 1,659.48 $ 3,743.09 $ 3,419.63 13 yr Existing Bulb Cost $ 3,743.09 $ 3,419.63 13 yr LED cost $ (1,659.48) 13 Year Conversion Savings $ 2,083.61 $ 1,760.15 Each Lamp Mercury vapor ballasts Effective January 1, 2008. Can no longer be manufactured or imported. Bans the sale of mercury lamp ballasts essentially banning the sale of new mercury vapor fixtures. Reference: GE Consumer & Industrical Environmental Info website: www.geconsumerandindustrial.com/environmentalinfo/regulations_resources/minimum_energy_efficiency_regulations.htm www.geconsumerandindustrial.com/environmentalinfo/regulations_resources/minimum_energy_efficiency_regulations.htm

16 Cost Comparison Chart 5 Yr ROI on Metal Halide 5.6 Yr ROI on High Pressure Sodium

17 Be Off The Grid.com Healing the Earth – one light at a time US Department of Energy ….2009 on LED Technology "No other lighting technology offers our nation so much potential to save energy and enhance the quality of our building environments.