Presentation is loading. Please wait.

Presentation is loading. Please wait.

More Wirescanner Results

Similar presentations


Presentation on theme: "More Wirescanner Results"— Presentation transcript:

1 More Wirescanner Results
Simulations Development of the e.m. cascade Expected energy deposition Measurements Beam sizes Correlations beam loss monitors–wirescanners Beam dynamics meeting, 2007/02/12 Lars Fröhlich/Eduard Prat, MPY

2 FLUKA simulations Beam dynamics meeting, 2007/02/12
Lars Fröhlich/Eduard Prat, MPY

3 Simulation: 50 µm W WS scintillators beam wire BLM scintillators
Beam dynamics meeting, 2007/02/12 Lars Fröhlich/Eduard Prat, MPY

4 Simulation: 10 µm W Beam dynamics meeting, 2007/02/12
Lars Fröhlich/Eduard Prat, MPY

5 Simulation: 10 µm C Beam dynamics meeting, 2007/02/12
Lars Fröhlich/Eduard Prat, MPY

6 Relative energy deposition
(scan with wire 21SEED.VER) 50 µm W 10 µm W (GeV/cm3/primary particle) deposited energy 10 µm C Beam dynamics meeting, 2007/02/12 Lars Fröhlich/Eduard Prat, MPY

7 Measurements Beam dynamics meeting, 2007/02/12
Lars Fröhlich/Eduard Prat, MPY

8 Beam Sizes 50 µm W @ 2.0 V 10 µm W @ 2.0 V 10 µm C @ 3.0 V
Beam dynamics meeting, 2007/02/12 Lars Fröhlich/Eduard Prat, MPY

9 Correlation BLM-WS 10 µm carbon wire, wirescanner PM at 3.5 V, BLM 3R
UND 1L 3L 1R 3R 5R 5L low WS signal, low BLM signal: linear behavior Beam dynamics meeting, 2007/02/12 Lars Fröhlich/Eduard Prat, MPY

10 10 µm carbon wire, wirescanner PM at 3.5 V, BLM 5L
Correlation BLM-WS 10 µm carbon wire, wirescanner PM at 3.5 V, BLM 5L UND 1L 3L 1R 3R 5R 5L low WS signal, higher BLM signal: BLM nonlinearity Beam dynamics meeting, 2007/02/12 Lars Fröhlich/Eduard Prat, MPY

11 50 µm tungsten wire, wirescanner PM at 2.0 V, BLM 3R
Correlation BLM-WS 50 µm tungsten wire, wirescanner PM at 2.0 V, BLM 3R higher WS signal, high BLM signal: BLM nonlinearity+WS nonlinearity? Beam dynamics meeting, 2007/02/12 Lars Fröhlich/Eduard Prat, MPY

12 50 µm tungsten wire, wirescanner PM at 2.5 V, BLM 3R
Correlation BLM-WS 50 µm tungsten wire, wirescanner PM at 2.5 V, BLM 3R higher wirescanner PM voltage: WS nonlinearity less distinct Beam dynamics meeting, 2007/02/12 Lars Fröhlich/Eduard Prat, MPY

13 First Conclusions BLMs and WSs are linear for low signals (BLM signal < 0.1) WSs have wider linear range than BLMs Carbon: signals entirely in WS linear range Reduction of WS light input will improve linearity Beam dynamics meeting, 2007/02/12 Lars Fröhlich/Eduard Prat, MPY

14 One more thing... Beam dynamics meeting, 2007/02/12
Lars Fröhlich/Eduard Prat, MPY

15 Relative Calibration signal per charge density (a.u. / (nC/mm))
Beam dynamics meeting, 2007/02/12 Lars Fröhlich/Eduard Prat, MPY

16 Relative Calibration relative signal strength SEED 1.158 UND1 0.498
0.826 UND3 1.930 UND4 0.941 UND5 0.865 UND6 0.783 relative signal strength Beam dynamics meeting, 2007/02/12 Lars Fröhlich/Eduard Prat, MPY

17 Relative Calibration relative signal strength
Beam dynamics meeting, 2007/02/12 Lars Fröhlich/Eduard Prat, MPY


Download ppt "More Wirescanner Results"

Similar presentations


Ads by Google