1 North Area Safety Review 2019
North Area Safety Review Gaz Detection Underground & Galleries premises Technical solutions & Cost estimates Resources estimates by S.Grau Thanks to: M. Averna, N.Broca from BE-ICS-AS for their contributions 6 Juin 2019 North Area Safety Review 2019

2 North Area Safety Review 2019
Outline Gas Detection Underground Galleries Maintenance Cost Consideration 6 Juin 2019 North Area Safety Review 2019

3 Gas Detection - Underground Technical Solution
Recommendations Assessment EHN2 installation arrives to the end of live (2004) Compulsory regular consolidation ECN3 Rationalisation gas detection infrastructure in SPS North Area Coherence for maintenance and FB Extension North Area architecture and technical solution to ECN3 and EHN2 6 Juin 2019 North Area Safety Review 2019

4 North Area Safety Review 2019
Gas Detection - Underground Cost Estimates Provided for NA-CONS-REPORT-001 Cost estimate based on existing gas detection coverage Real prices of B1159 contract 6 Juin 2019 North Area Safety Review 2019

5 Gas Detection - Galleries Technical Solution
North Area Gas Safety Concept (EDMS , ) Recommendations Assessment ODH and CO2 risk exists in the gallery of EHN1,ECN3, EHN2 due to the lack of ventilation and the thus stagnating air in the gallery: The current ODH detection system is not fit-for-purpose. The fixed ODH detectors can even give a false sense of safety and we recommend to removed them/are not sufficient. The use of portable ODH and CO2 detectors is advisable instead. Considering the presence of CO2, it is recommended to implemented CO2 detectors or wear portable CO2 detectors. Requested by project only Extension North Area architecture and technical solution to galleries Pre-requisite: renewal of EHN2 and upgrade of ECN3 Extension of EHN2&ECN3 and EHN1 Saleve infrastructure needed EDMS 6 Juin 2019 North Area Safety Review 2019

6 Gas Detection - Galleries Technical Solution
EDMS 6 Juin 2019 North Area Safety Review 2019

7 North Area Safety Review 2019
Gas Detection - Galleries Cost Estimates Provided for NA-CONS-REPORT-001 Cost estimated based on umber of detectors and flashes in conceptual design Real prices of B1159 contract 15 % Contingency 6 Juin 2019 North Area Safety Review 2019

8 North Area Safety Review 2019
Gas Detection – Under. & Galleries Cost & Resources Estimates Update for Safety Review Cost Estimate Assessment 220 KCHF EHN2 Compulsory regular consolidation 80 KCHF ECN3 Coherence for maintenance and FB 425 KCHF Galleries Requested by project only Resources FTE required BE-ICS-AS 0.3 FTE/year of project (2y) 0.5 FTE/year of project (2y) 6 Juin 2019 North Area Safety Review 2019

9 North Area Safety Review 2019
Maintenance cost Cost Estimates Provided for NA-CONS-REPORT-001 Cost estimates based on B1159 prices for traditional fire detection Update for Safety Review Cost Estimate + 30 kCHF/year +/- 20 % 6 Juin 2019 North Area Safety Review 2019

10 North Area Safety Review 2019
Considerations Extensions of B1159, no need to go through an IT Installation time of 1 year seems ambitious EN/EL planned ENH2 cabling Cabling for Galleries not requested to EN/EL 6 Juin 2019 North Area Safety Review 2019