1 API Subcommittee on Well Cements (SC-10) Surfactant Testing WG 2018 Summer Meeting Progress Report

2 Today Members Workgroup charge/ Current Status Discussion

3 Team Members Steven Riedinger Chevron Co-Chair Rick Lukay Ofite Coach
Kevin Fort Exxon Aaron Dondale BP Matthew Kellum BHI Gunnar DeBruijn SLB Kevin Docherty SLB Mark Meade SLB Samuel Lewis Hal Felipe Padila BJS Paul Sonnier CSI Shailesh Dighe BHI Co-Chair 11 Members 8 Organizations

4 Current Status Baseline testing was performed in every laboratory by using their own methods but same samples (discussed in the Winter meeting) A new shear bond testing procedure and setup developed by using fluid loss cell to correlate SSST results 1st Round testing Almost completed – Every laboratory used the API fluid loss cell with same samples as previous test

5 Previous Findings Combined Std. Dev.: 134 psi Std. Dev./Median: 45%
Median: 303 psi

6 Previous Findings

7 Details of WG Activities
Three Rounds of Testing with unified procedure Round 1 – Shear bond with No Pre-treatment Round 2 – Shear bond with Drilling Fluid Pre-treatment Round 3 – Shear bond with Drilling Fluid and Surfactant Pre-treatment

8 Latest WG Findings

9 Latest WG Findings Combined Std. Dev.: 81 psi Std. Dev./Median: 18%
Median: 442 psi Std. Dev./Median w/o Outliers: 12%

10 Comparison Average of Set to Average of All Sets

11 Round 1 Testing Details Use API cell for shear bond mold
Mix slurry as per API 10B2 Condition slurry in Atmp. Const. 80F – 20min Place Cell in water bath 120F for 72hrs Use Constant Load rate at 4000 lbf/min

12 Best Practices Face to Face for the writing of the unified shear bond procedure First test done in one lab. with WG members witnessing the steps Adjustment of procedure during first test to accurately reflect steps

13 Next steps Perform 2nd Round test in all laboratory with Mud
Perform 3rd Round test with Mud and Surfactant Analyze by % change and absolute Compare Results – if above works to SSST