1

2 Honeywell Fire Systems Group

3 RFX SLC L1: Det.159 Mod. 159 SLC L2: Det.159 Mod. 159 SLC L3 ~ L10 EIA 485 EIA 232 RDP Up to 32 Noti-Fire-Net Onyxworks 4 Set On Board Relay O/P

4 Honeywell Fire Systems Group TB4TB3TB2TB1 ALARM TROUBLE SUPV SCTY TB7 ACS TB9 RDP TB5 PRN TB6 +24V J4 BACKLIGHT J2 LCD J9 KEYPAD J13 AMPS-24 J6 SCTY J5 TROUBLE J1 NUP J7 SLC

5 Honeywell Fire Systems Group Display & Function Keys Function LEDs Function Keys

6 Honeywell Fire Systems Group TO NEXT LCM FROM CPU J7 or LCM SLC WIRING LEM CONNECTION

7 Honeywell Fire Systems Group Loop Modules J3 J1 J2 JP1 D33 +5V D32 D28 B+ A+ B- A- SLC JP2 TB1 JP3 SW1 EG FAULT LCM-320 LEM-320 LEM Ground Fault LCM Ground Fault

8 Honeywell Fire Systems Group LCM Cables

9 Honeywell Fire Systems Group LCM/LEM SLC Connector Channel B Channel A Typical Style 4.0 Channel B Output Channel A Return Typical Style 6.0/7.0

10 Honeywell Fire Systems Group AMPS-24(E) Power Supply TB3 AC TB1 SLC TB2 CPU TB6 Accessory Power SW1 Configuration Switches TB4 & 5 DC SW4 Charger Selection

11 Honeywell Fire Systems Group AMPS-24E (New Version) AC Input: AC 220V DC Output: 24VDC, 5A for CPU 24VDC, 3A for External Devices Battery Charger: 24VDC 7 – 200AH

12 Honeywell Fire Systems Group Base Address Setting

13 Honeywell Fire Systems Group Properties setup via software kit

14 Honeywell Fire Systems Group Setup Battery and Charger Current

15 Honeywell Fire Systems Group APS2-6RE – Auxiliary Power Supply AC Input: AC 220V DC Output: 24VDC, 3A (2 set) 24VDC, 6A (1 set) (Total 24VDC, 6A)

16 Honeywell Fire Systems Group Addressable Charger Power Supply ACPS 610(E) AC Input: AC 220V DC Output: 24VDC, 1.25A x 4 Circuits Battery Charger: 24VDC 7 – 200AH

17 Honeywell Fire Systems Group LCD-160 Remote Display TB1 RDP Bus 12 to 18 AWG Max 4K feet total Max 100 ohms TB2 24v Power From AMPS-24 From APS-6R Max 10 ohms SW17 #1 ON: Prog #2 ON: ELR 160 character display Custom graphics Tactile keypad DCC participation

18 Honeywell Fire Systems Group ACM (AEM) – 48 A A1P1 A1P2 A1P3 A1P4 ACM(AEM)-24AT ACS Annunciators

19 Honeywell Fire Systems Group ACS Annunciators 0 1 2 3 4 5 7 9 8 6 0 1 2 3 4 5 7 9 8 6 1 2 3 4 5 6 7 8 ACM-8R LDM-32 series

20 Honeywell Fire Systems Group ACS Annunciators Switch Group 5 Switch Group 6 Switch Group 7 Switch Group 8 Switch Group 1 Switch Group 2 Switch Group 3 Switch Group 4 All Auto Manual Acknowledge SCS-8 Smoke Control Station

21 Honeywell Fire Systems Group Smoke Control Station Up to four modules/group Three position toggle switches –On / Off / Auto Control On Control Off Monitor On Monitor Off SCS-8

22 Honeywell Fire Systems Group Network Communications Module To communicate with another Onyx control panel on a network, the Onyx Panels requires an Network Control Module. The NCM is capable of working on a either a wire or a fiber network. NCM-W (Wire) NCM-F (Fiber optic) Mounting Options: In a standard Chassis position. On the right side of a DAA Audio Amplifier. Underneath the DVC Digital Video Controller. NCM-W

23 Honeywell Fire Systems Group A B Network Node A B Network Node or RPT A B Network Node or RPT A B Network Node Point-To-Point Configuration A point-to-point wiring configuration is defined as a twisted- pair segment with only two nodes/repeaters attached to it. Terminating resistors are required at each end of every segment, and are built into each MIB/RPT/NCM.

24 Honeywell Fire Systems Group A B Network Node or RPT A B Network Node or RPT A B Network Node or RPT A B Network Node or RPT Point-To-Point Configuration Wiring a Noti-Fire-Net in NFPA Style 7 point-to- point.

25 Honeywell Fire Systems Group CPU-3030D or CPU-3030ND Both CPU options require a CHS-M3 chassis for mounting in the top position of the cabinet. SBB-D4 D-Size Backbox CPU2 mounting LCM/LEM and NCM-W/F can be installed in the two right- hand positions. BATTERY AMPS-24(E)

26 Honeywell Fire Systems Group CHS-4L CHS-4L Chassis, low profile, 4 positions for mounting the LCM/LEM, NCM-W/F, APS-6R, LDM-32, BACNet GW... D-Size Backbox

27 Honeywell Fire Systems Group Dress Panels & Plates * Use to BMP-1 Blank Module plate to cover unused single positions DP-1B Blank Dress Plate, 4 row ADP-4B Annunciator Dress Plate* BP2-4 Battery Dress Plate DP-DISP Display Dress Plate

28 Honeywell Fire Systems Group The assembly consists of a back box and a locking door with two keys. The back box and door can be ordered separately or as a complete unit. Doors may be hinged right or left. A semi-flush trim ring kit is available for each box size. Page 19 DR-A4 SBB-A4

29 Honeywell Fire Systems Group Page 19 SBB-B4 DR-B4

30 Honeywell Fire Systems Group Page 20 SBB-C4 DR-C4

31 Honeywell Fire Systems Group Page 20 SBB-D4 DR-D4

32 Honeywell Fire Systems Group ABS-4D ABS-2D

33 Honeywell Fire Systems Group