1 DCNNG Multi CCU System Setup
12.Mar.07 DCNNG MCCU System Setup

2 DCNNG Multi CCU System Setup
A basic multi-CCU system. The following can be connected to a multi-CCU system: A maximum of 30 DCN-CCU devices. A maximum of 4000 delegate positions (Stand-alone and Microphone function only). A maximum of 1500 delegate positions with PC control. A maximum of 32 audio channels (1 Floor and 31 channels for Interpretation). 12.Mar.07 DCNNG MCCU System Setup

3 DCNNG Multi CCU System with 490 Concentus units
Up to 245 addresses can be connected to one CCU. All active units use an address. (Concentus Units are active units) AutoDome RS 232 Optional PC Control Ethernet link DCN-NCO For redundancy only Seat 1 CCU 1 Seat 245 Seat 246 Seat 490 CCU 2 12.Mar.07 DCNNG MCCU System Setup

4 Up to 245 addresses can be connected to one CCU.
DCNNG Multi CCU System with 426 Concentus units and 64 Interpreter Desks Up to 245 addresses can be connected to one CCU. All active units use an address. (Concentus Units and Interpreter desks are both active units) AutoDome RS 232 Optional PC Control Ethernet link DCN-NCO CCU 1 Seat 1 Seat 245 CCU 2 Seat 246 Seat 426 IDESK 1 IDESK 64 Audio Expander 12.Mar.07 DCNNG MCCU System Setup

5 Up to 245 addresses can be connected to one CCU.
DCNNG Multi CCU System with 490 Concentus units and # Interpreter Desks Up to 245 addresses can be connected to one CCU. All active units use an address. (Concentus Units and Interpreter desks are both active units) AutoDome RS 232 Optional PC Control Ethernet link DCN-NCO CCU 1 Seat 1 Seat 245 CCU 2 Seat 246 Seat 490 CCU 3 n 12.Mar.07 DCNNG MCCU System Setup

6 DCNNG Multi CCU System Single Room or combined Rooms
Up to 245 addresses can be connected to one CCU. All active units use an address. (Concentus Units and Interpreter desks are both active units) Interlock between booths on separate CCU‘s cannot be used in “None” - mode. DCN-NCO CCU 1 1 n 1 n Room 1 CCU 2 1 n 1 n Room 2 CCU 3 1 n 1 n Room 3 12.Mar.07 DCNNG MCCU System Setup

7 DCNNG Multi CCU System up to 1225 seats
Up to 245 addresses can be connected to one CCU. DCN Dual Delegates Units use an address. Each unit controls two seat numbers. AutoDome RS 232 Optional PC Control Ethernet link DCN-NCO CCU 1 Unit Unit Seat 1 & 2 Seat 489 & 490 CCU 2 Unit Unit Seat 491 & 492 Seat 979 & 980 CCU 3 Unit Unit Seat 981 & 982 Seat 1224 & 1225 12.Mar.07 DCNNG MCCU System Setup

8 DCNNG Multi CCU System Setup
End of section MCCU Menu 12.Mar.07 DCNNG MCCU System Setup