Presentation is loading. Please wait.

Presentation is loading. Please wait.

UNIT – IV Interrupts V SUPRAJA.

Similar presentations


Presentation on theme: "UNIT – IV Interrupts V SUPRAJA."— Presentation transcript:

1 UNIT – IV Interrupts V SUPRAJA

2 Interrupts are commonly used for a range of applications:
Urgent tasks that must be executed promptly at higher priority than the main code. However, it is even faster to execute a task directly by hardware if this is possible. Infrequent tasks, such as handling slow input from humans. This saves the overhead of regular polling. Waking the CPU from sleep. This is particularly important in the MSP430, which typically spends much of its time in a low-power mode and can be awakened only by an interrupt. Calls to an operating system. These are often processed through a trap or software interrupt instruction but the MSP430 does not have one. A substitute is for software to set an unused interrupt flag for one of the peripherals, such as port P1 or P2. V SUPRAJA

3 What Happens when an Interrupt Is Requested?
A lengthy chain of operations lies between the cause of a maskable interrupt and the start of its ISR Hardware then performs the following steps to launch the ISR: 1. Any currently executing instruction is completed if the CPU was active when the interrupt was requested. MCLK is started if the CPU was off. 2. The PC, which points to the next instruction, is pushed onto the stack. 3. The SR is pushed onto the stack. 4. The interrupt with the highest priority is selected if multiple interrupts are waiting for service. V SUPRAJA

4 5. The interrupt request flag is cleared automatically for vectors that have a single source. Flags remain set for servicing by software if the vector has multiple sources, which applies to the example of TAIFG. 6. The SR is cleared, which has two effects. First, further maskable interrupts are disabled because the GIE bit is cleared; nonmaskable interrupts remain active. 7. The interrupt vector is loaded into the PC and the CPU starts to execute the interrupt service routine at that address. V SUPRAJA

5 V SUPRAJA

6 An interrupt service routine must always finish with the special return from interrupt instruction reti, which has the following actions: The SR pops from the stack. All previous settings of GIE and the mode control bits are now in effect, regardless of the settings used during the interrupt service routine. In particular, this reenables maskable interrupts and restores the previous low-power mode of operation if there was one. 2. The PC pops from the stack and execution resumes at the point where it was interrupted. Alternatively, the CPU stops and the device reverts to its low-power mode before the interrupt. V SUPRAJA

7 (Non)-Maskable Interrupts (NMI)
The MSP430x5xx family supports two levels of NMI interrupts, system NMI (SNMI) and user NMI (UNMI). In general, (Non)-maskable NMI interrupts are not masked by the general interrupt enable bit (GIE). A (non)-maskable user NMI interrupt can be generated by following sources: An edge on the RST/NMI pin when configured in NMI mode An oscillator fault occurs An access violation to the flash memory V SUPRAJA

8 Power Management Module (PMM) supply voltage fault PMM time out
A (non)-maskable system NMI interrupt can be generated by following sources: Power Management Module (PMM) supply voltage fault PMM time out Vacant memory access JTAG mailbox event Maskable Interrupts Maskable interrupts are caused by peripherals with interrupt capability. Each maskable interrupt source can be disabled individually by an interrupt enable bit, or all maskable interrupts can be disabled by the general interrupt enable (GIE) bit in the status register (SR) V SUPRAJA

9 Issues Associated with Interrupts
Keep Interrupt Service Routines Short Other interrupts, which may be urgent, are disabled during an ISR unless you choose to allow nested interrupts. 2. Configure Interrupts Carefully Make sure that unwanted interrupts are disabled Make sure that the module is fully configured before interrupts are enabled. Do not set the GIE bit until you are ready to handle interrupts. V SUPRAJA

10 3. Define All Interrupt Vectors
define a single ISR for unused interrupts that traps the processor in an infinite loop. The address of this routine can then be stored in all the unused interrupt vectors. Use the debugger to trace back if one of these interrupts arises. 4. The Shared Data Problem This is one of the classic issues with interrupts and multitasking systems It arises when variables are used both in the main function and in ISRs. V SUPRAJA

11 DisplayMinutes (MinsOfDay ); DisplayHours (MinsOfDay );
Suppose that the time was 01:59 when DisplayMinutes was called but has been updated to 02:00 by the time that Display Hours is called. The displayed time will be 02:59 V SUPRAJA

12 Interrupt vector Table
V SUPRAJA 11

13 Low Power Modes The MSP430 family is designed for ultra low-power applications and uses different operating modes The operating modes take into account three different needs: ·Ultralow-power · Speed and data throughput ·Minimization of individual peripheral current consumption The low-power modes LPM0 through LPM4 are configured with the CPUOFF, OSCOFF, SCG0, and SCG1 bits in the status register V SUPRAJA

14 An interrupt automatically switches the device to active mode.
CPU, all clocks, and enabled modules are active, I ≈ 300A. The MSP430 starts up in this mode, which must be used when the CPU is required. An interrupt automatically switches the device to active mode. The current can be reduced by running the MSP430 at the lowest supply voltage VCC can be lowered to 1.8V for fDCO = 1MHz, giving I ≈ 200A. V SUPRAJA

15 CPU and MCLK are disabled, SMCLK and ACLK remain active, I ≈ 85A.
LPM0: CPU and MCLK are disabled, SMCLK and ACLK remain active, I ≈ 85A. This is used when the CPU is not required but some modules require a fast clock from SMCLK and the DCO. LPM3: CPU, MCLK, SMCLK, and DCO are disabled; only ACLK remains active; I ≈ 1A This is the standard low-power mode when the device must wake itself at regular intervals and therefore needs a (slow) clock The current can be reduced to about 0.5A by using the VLO instead of an external crystal in a MSP430F2xx V SUPRAJA

16 LPM4: CPU and all clocks are disabled, I ≈ 0.1A. The device can be wakened only by an external signal. This is also called RAM retention mode. V SUPRAJA

17 CPU Operating modes V SUPRAJA

18 Waking from a Low power mode
An interrupt is needed to awaken the MSP430. The processor handles an interrupt from a low-power mode in almost the same way as in active mode Status register is cleared when an interrupt is accepted, which puts the processor into active mode MCLK is automatically turned off at the end of the ISR if the MSP430 returns to a low-power mode when the status register is restored. V SUPRAJA

19 Sometimes it is not appropriate to carry out all actions in an ISR and it is better to return to the main function in active mode In this case we must clear all the low-power bits in the saved value of SR on the stack before it is restored at the end of the interrupt service routine. V SUPRAJA

20 Entering and Exiting Low-Power Modes
Enter interrupt service routine: – The PC and SR are stored on the stack – The CPUOFF, SCG1, and OSCOFF bits are automatically reset Options for returning from the interrupt service routine: – The original SR is popped from the stack, restoring the previous operating mode. – The SR bits stored on the stack can be modified within the interrupt service routine V SUPRAJA

21 Watchdog Timer The main purpose of the watchdog timer is to protect the system against failure of the software, such as the program becoming trapped in an unintended, infinite loop. If the selected time interval expires, a system reset is generated. The operation of the watchdog is controlled by the 16-bit register WDTCTL V SUPRAJA

22 Features of the watchdog timer module include:
· Eight software-selectable time intervals · Watchdog mode · Interval mode · Access to WDT control register is password protected · Selectable clock source · Can be stopped to conserve power · Clock fail-safe feature V SUPRAJA

23 V SUPRAJA

24 WDTCTL is a 16-bit, password-protected, read/write register
The WDT module can be configured as either a watchdog or interval timer with the WDTCTL register. WDTCTL is a 16-bit, password-protected, read/write register write accesses must include the write password 05Ah in the upper byte Any read of WDTCTL reads 069h in the upper byte. The watchdog timer counter (WDTCNT) is a 32-bit up-counter that is not directly accessible by software The WDTCNT can be sourced from SMCLK, ACLK, VLOCLK and X_CLK on some devices. The clock source is selected with the WDTSSEL bits V SUPRAJA

25 V SUPRAJA

26 A PUC resets the WDT to its default condition. Interval Timer Mode:
Watchdog Mode: After a PUC condition, the WDT module is configured in the watchdog mode with an initial ~32-ms reset interval using the SMCLK Once it configured in Watchdog mode writing to WDTCTL with an incorrect password, or expiration of the selected time interval triggers a PUC. A PUC resets the WDT to its default condition. Interval Timer Mode: Set WDTTMSEL bit to 1 to select the interval timer mode. This mode can be used to provide periodic interrupts V SUPRAJA

27 WDTIFG enable bit WDTIE remains unchanged Clock Fail-Safe Feature:
In interval timer mode, the WDTIFG flag is set at the expiration of the selected time interval. A PUC is not generated in interval timer mode at expiration of the selected timer interval and the WDTIFG enable bit WDTIE remains unchanged Clock Fail-Safe Feature: The WDT_A provides a fail-safe clocking feature assuring the clock to the WDT_A cannot be disabled while in watchdog mode. This means the low-power modes may be affected by the choice for the WDT_A clock. V SUPRAJA

28 If SMCLK or ACLK fails as WDT_A clock source then VLOCLK is automatically selected as WDT_A clock source. When the WDT_A module is used in interval timer mode, there is no fail-safe feature within WDT_A for the clock source. V SUPRAJA

29 V SUPRAJA

30 CLOCK SYTEM All microcontrollers contain a clock module to drive the CPU and peripherals clock signal is a square wave whose edges trigger hardware throughout the device so that the changes in different components are synchronized. A crystal with a frequency of a few MHz would be connected to two pins. It would drive the CPU directly and was typically divided down by a factor of 2 or 4 for the main bus Modern Microcontrollers demands high performance and low power complicated clocks, often with two or more sources V SUPRAJA

31 Two clocks with quite different specifications are often needed:
• A fast clock to drive the CPU, which can be started and stopped rapidly to conserve energy but usually need not be particularly accurate. • A slow clock that runs continuously to monitor real time, which must therefore use little power and may need to be accurate. V SUPRAJA

32 Several types of oscillator are used to generate the clock signal.
Crystal: Accurate and stable. Crystals for microcontrollers typically run at either a high frequency of a few MHz to drive the main bus or a low frequency of 32,768 Hz for a real-time clock. The disadvantages are that crystals are expensive and delicate, the oscillator draws a relatively large current, particularly at high frequency. the crystal is an extra component and may need two capacitors as well. Crystal oscillators also take a long time to start up and stabilize, often around 105 cycles V SUPRAJA

33 Resistor and capacitor (RC):
Cheap and quick to start but used to have poor accuracy and stability. The components can be external but are now more likely to be integrated within the MCU. The quality of integrated RC oscillators has improved dramatically in recent years There are also ceramic resonators that lie between these extremes, being cheaper but less accurate and stable than crystals. V SUPRAJA

34 The MSP430 addresses the conflicting demands for high performance, low power, and a precise frequency by using three internal clocks: • Master clock, MCLK, is used by the CPU and a few peripherals. • Subsystem master clock, SMCLK, is distributed to peripherals. • Auxiliary clock, ACLK, is also distributed to peripherals. SMCLK runs at the same frequency as MCLK, both in the megahertz range(1MHz). ACLK is often derived from a watch crystal and therefore runs at a much lower frequency(32KHz). Most peripherals can select their clock from either SMCLK or ACLK. V SUPRAJA

35 Simplified block diagram of the clock module of the MSP430F2xx family
V SUPRAJA

36 V SUPRAJA

37 Crystal Oscillators, LFXT1 and XT2
Crystals are used when an accurate, stable frequency is needed: • Accurate means that the frequency is close to what it says on the package, typically within 1 part in 105. • Stable means that does not change significantly with time or temperature. Traditional crystals oscillated at frequencies of a few MHz. Small microcontrollers use low frequency watch crystals with frequency 32Kz. Low frequency crystals disadvantage is they are more sensitive to temperature than high-frequency crystals. A change of 10◦C in the temperature causes the frequency to fall by about 4 parts per million (ppm). V SUPRAJA

38 The circuit is known as a Pierce oscillator and also requires a
Oscillator circuits are integrated into the MSP430 and the crystal should be connected to pins XIN and XOUT. The circuit is known as a Pierce oscillator and also requires a capacitance (10pf) to ground from each pin. The oscillator is designed to run at low power and this renders it susceptible to electromagnetic interference. It is also possible to use high-frequency crystals (above 400 KHz) with LFXT1 in most devices and some have a second oscillator XT2, which works only at high frequencies. The stability of crystals is reflected electrically in their high Q factor. This means that they oscillate for a long time after being excited. The disadvantage of this is that the oscillator takes an equally long time to reach a stable state, typically around 105 cycles V SUPRAJA

39 Internal Low-Power, Low-Frequency Oscillator, VLO
The VLO is an internal RC oscillator that runs at around 12 KHz and can be used instead of LFXT1 in some newer devices. It saves the cost and space required for a crystal and reduces the current drawn. LFXT1 draws about 0.8A, which falls to 0.5A with the VLO This is not impressive in terms of accuracy and stability A variation of 10◦C changes the frequency by about 5% .you would not use the VLO for serious timing. The purpose is often to wake the device periodically to check whether any inputs have changed, and accuracy is not important. V SUPRAJA

40 ACLK is taken from LFXT1 by default even where the VLO is present.
This means that current is wasted in LFXT1 and that pins P2.6 and P2.7 in the F20xx are configured for a crystal. It is usually a good idea to reconfigure the BCM+ to use the VLO and redirect port 2 for digital input/output. V SUPRAJA

41 Digitally Controlled Oscillator, DCO
One of the aims of MSP430 was that it should be able to start rapidly at full speed from a low-power mode, without waiting a long time for the clock to settle. Early versions of the DCO started in 6s, which has been reduced to 1–2s in the MSP430F2xx family. The frequency can be controlled through sets of bits in the module’s registers at three levels RSELx: Selects one of 16 coarse ranges of frequency. The overall range is about 0.09–20 MHz's DCOx: Selects one of eight steps within each range. Each step increases the frequency by about 8%, giving a factor of 1.7 from bottom to top of the range. V SUPRAJA

42 V SUPRAJA

43 The average frequency is obtained by modulating the frequency of the oscillator between the selected value of DCO and the next step up (DCO+1). V SUPRAJA

44 Control of the Clock Module through the Status Register
CPUOFF disables MCLK, which stops the CPU and any peripherals that use MCLK. SCG1 disables SMCLK and peripherals that use it. SCG0 disables the DC generator for the DCO (disables the FLL in the MSP430x4xx family). OSCOFF disables VLO and LFXT1. V SUPRAJA

45 Introduction: Digital Input & Output
MSP430x5xx devices may have up to 12 digital I/O ports implemented, P1 to P11 and PJ. Most ports have eight I/O pins, however some ports may contain less. All ports have individually configurable pullup or pulldown resistors, as well as, configurable drive strength. Ports P1 and P2 always have interrupt capability. Individual ports can be accessed as byte wide ports or can be combined into word wide ports and accessed via word formats. Port pairs P1/P2, P3/P4, P5/P6, P7/P8, etc. are associated with the names PA, PB, PC, PD, etc., respectively V SUPRAJA

46 The digital I/O features include:
· Independently programmable individual I/Os · Any combination of input or output · Individually configurable P1 and P2 interrupts · Independent input and output data registers · Individually configurable pullup or pulldown resistors Digital I/O Operation: > The digital I/O is configured with user software Each bit in each PxIN register reflects the value of the input signal at the corresponding I/O pin. These registers are read only. · Bit = 0: The input is low · Bit = 1: The input is high V SUPRAJA

47 Output Registers PxOUT:
Each bit in each PxOUT register is the value to be output on the corresponding I/O pin. · Bit = 0: The output is low · Bit = 1: The output is high Direction Registers PxDIR: Each bit in each PxDIR register selects the direction of the corresponding I/O pin · Bit = 0: Port pin is switched to input direction · Bit = 1: Port pin is switched to output direction Pullup/Pulldown Resistor Enable Registers PxREN: Each bit in each PxREN register enables or disables the pullup/pulldown resistor of the corresponding I/O pin. · Bit = 0: Pullup/pulldown resistor disabled · Bit = 1: Pullup/pulldown resistor enabled V SUPRAJA

48 V SUPRAJA

49 Output Drive Strength Registers PxDS:
> Each bit in each PxDS register selects either full drive or reduced drive strength. Default is reduced drive strength. · Bit = 0: Reduced drive strength · Bit = 1: Full drive strength Function Select Registers PxSEL: Port pins are often multiplexed with other peripheral module functions. Each PxSELx bit is used to select the pin function - I/O port or peripheral module function. · Bit = 0: I/O Function is selected for the pin · Bit = 1: Peripheral module function is selected for the pin > P1 and P2 Interrupts Are Disabled When PxSEL = 1 V SUPRAJA

50 P1 and P2 Interrupts: > Each pin in ports P1 and P2 have interrupt capability, configured with the PxIFG, PxIE, and PxIES registers. All P1 interrupt flags are prioritized, with P1IFG.0 being the highest. The highest priority enabled interrupt generates a number in the P1IV register. This number is added to PC. Each PxIFGx bit is the interrupt flag for its corresponding I/O pin. All PxIFGx interrupt flags request an interrupt when their corresponding PxIE bit and the GIE bit are set. In PxIFG flag if bit is 0 no interrupt is pending. If bit is 1 interrupt is pending. V SUPRAJA

51 V SUPRAJA

52 Configuring Unused Port Pins
Unused I/O pins should be configured as I/O function, output direction, and left unconnected on the PC board, to prevent a floating input and reduce power consumption. The value of the PxOUT bit is don't care, since the pin is unconnected. the integrated pullup/pulldown resistor can be enabled by setting the PxREN bit of the unused pin to prevent the floating input V SUPRAJA

53 Operating Modes Active Mode Low Power Mode 0(LPM0)
V SUPRAJA

54 Memory Organization 512 Bytes= 1FF 128 Bytes=7F 2K=7FF 32K=7FFF
V SUPRAJA

55 FRAM vs Flash Ultra-low-power Read/Write With Increased Throughput
Read and writes require just 1.5V, so it is able to operate without a charge pump, unlike Flash and EEPROM. This lowers power and minimizes physical footprint. FRAM consumes 250x less power than Flash-based devices when running at equal speed (12kB/s) Test case - CPU 8MHz - Both memory options 12kB/s throughput (typical application) FRAM consumes 12kB/s Flash consumes 12kB/s V SUPRAJA

56 Both writing to memory at 12kB/s Summary: At equal throughput, FRAM consumes 250x less power than Flash V SUPRAJA

57 Industry-Leading Read/Write Speeds
In addition to lower power performance, FRAM can also maintain unmatched data throughput. MSP430 with embedded FRAM is capable of 50ns access times, enabling speeds up to 1400 kB/s. > With FRAM, embedded memory is no longer the bottle neck of your application. FRAM can write more than 100x faster than flash, while consuming less power! Test case - CPU 8MHz - Both memory options writing 512B memory blocks FRAM max throughput = 730μA Flash max throughput = 2200μA V SUPRAJA

58 Summary: FRAM maximum throughput is >100x faster than Flash maximum throughput, while still consuming 3x lower power than Flash V SUPRAJA

59 Virtually Unlimited Write Endurance – 1014 Cycles
Embedded FRAM also offers endurance that existing memory technologies cannot match. FRAM offers virtually unlimited endurance at 1014 cycles This increased write endurance is particularly ideal for data logging, digital rights management, battery-backed SRAM and other applications. FRAM offers virtually unlimited write endurance of 1014 cycles – this is 1,000,000,000 times better than Flash! Test case - CPU 8MHz - Both memory options 12kB/s throughput (typical application) FRAM will last for 6.6x10^10 seconds Flash will last for 6.6 minutes V SUPRAJA

60 Summary: FRAM's increased write endurance enables 1,000,000,000x longer memory life cycles than Flash V SUPRAJA

61 Timer_A Timer_A is a 16-bit timer/counter with up to seven capture/compare registers. Timer_A can support multiple capture/compares, PWM outputs, and interval timing. Timer_A also has extensive interrupt capabilities. V SUPRAJA

62 V SUPRAJA

63 V SUPRAJA

64 Timer_A Operation The Timer_A module is configured with user software
16-Bit Timer Counter: The 16-bit timer/counter register, TAR, increments or decrements (depending on mode of operation) with each rising edge of the clock signal. TAR can be read or written with software. Additionally, the timer can generate an interrupt when it overflows. TAR may be cleared by setting the TACLR bit. Setting TACLR also clears the clock divider and count direction for up/down mode. V SUPRAJA

65 Clock Source Select and Divider:
The timer clock TACLK can be sourced from ACLK, SMCLK, or externally via TACLK. The clock source is selected with the TASSELx bits. The selected clock source may be passed directly to the timer or divided by 2, 4, or 8, using the IDx bits . The selected clock source can be further divided by 2, 3, 4, 5, 6, 7, or 8 using the IDEXx bits. The TACLK dividers are reset when TACLR is set. Starting the Timer The timer may be started, or restarted in the following ways: · The timer counts when MCx > 0 and the clock source is active. · When the timer mode is either up or up/down, the timer may be stopped by writing 0 to TACCR0. V SUPRAJA

66 Timer Mode Control V SUPRAJA

67 Changing the Period Register TACCR0
Up Mode The up mode is used if the timer period must be different from 0FFFFh counts. When the timer value equals TACCR0 the timer restarts counting from zero Changing the Period Register TACCR0 When changing TACCR0 while the timer is running, if the new period is greater than or equal to the old period, or greater than the current count value, the timer counts up to the new period. If the new period is less than the current count value, the timer rolls to zero V SUPRAJA

68 V SUPRAJA

69 V SUPRAJA

70 Use of the Continuous Mode
The continuous mode can be used to generate independent time intervals and output frequencies. Each time an interval is completed, an interrupt is generated. V SUPRAJA

71 V SUPRAJA

72 Changing the Period Register TACCR0
When changing TACCR0 while the timer is running, and counting in the down direction, the timer continues its descent until it reaches zero. The new period takes affect after the counter counts down to zero. When the timer is counting in the up direction, and the new period is greater than or equal to the old period, or greater than the current count value, the timer counts up to the new period before counting down. When the timer is counting in the up direction, and the new period is less than the current count value, the timer begins counting down. V SUPRAJA

73 Capture/Compare Blocks
Three or five identical capture/compare blocks, TACCRx, are present in Timer_A. Any of the blocks may be used to capture the timer data, or to generate time intervals. Capture Mode: The capture mode is selected when CAP = 1. Capture mode is used to record time events. The capture inputs CCIxA and CCIxB are connected to external pins or internal signals and are selected with the CCISx bits. The CMx bits select the capture edge of the input signal as rising, falling, or both. A capture occurs on the selected edge of the input signal. If a capture occurs: · The timer value is copied into the TACCRx register · The interrupt flag CCIFG is set V SUPRAJA

74 V SUPRAJA

75 V SUPRAJA

76 Compare Mode The compare mode is selected when CAP = 0. The compare mode is used to generate PWM output signals or interrupts at specific time intervals. When TAR counts to the value in a TACCRx: · Interrupt flag CCIFG is set · Internal signal EQUx = 1 · EQUx affects the output according to the output mode · The input signal CCI is latched into SCCI Output Unit Each capture/compare block contains an output unit. The output unit is used to generate output signals such as PWM signals. Each output unit has eight operating modes that generate signals based on the EQU0 and EQUx signals. V SUPRAJA

77 Output Modes V SUPRAJA

78 V SUPRAJA

79 V SUPRAJA

80 Two interrupt vectors are associated with the 16-bit Timer_A module:
Timer_A Interrupts Two interrupt vectors are associated with the 16-bit Timer_A module: · TACCR0 interrupt vector for TACCR0 CCIFG · TAIV interrupt vector for all other CCIFG flags and TAIFG In capture mode any CCIFG flag is set when a timer value is captured in the associated TACCRx register. In compare mode, any CCIFG flag is set if TAR counts to the associated TACCRx value. V SUPRAJA

81 Timer_B Timer_B is a 16-bit timer/counter with three or seven capture/compare registers. Timer_B can support multiple capture/compares, PWM outputs, and interval timing. Timer_B also has extensive interrupt capabilities. Interrupts may be generated from the counter on overflow conditions and from each of the capture/compare registers. Timer_B is identical to Timer_A with the following exceptions: · The length of Timer_B is programmable to be 8, 10, 12, or 16 bits. · Timer_B TBCCRx registers are double-buffered and can be grouped. · All Timer_B outputs can be put into a high-impedance state. · The SCCI bit function is not implemented in Timer_B. V SUPRAJA

82 Timer-B Block Diagram V SUPRAJA

83 V SUPRAJA

84 Real-Time Clock A Real-Time Clock (RTC) module has been added to recent devices in the MSP430xFxx family. It counts seconds, minutes, hours, days, months, and years. Alternatively it can be used as a straightforward counter. This can be configured in calendar mode or Counter mode. The current time and date are held in a set of registers that contain the following bytes: • Second (RTCSEC). • Minute (RTCMIN). • Hour (RTCHOUR), which runs from 0–23 (24-hour format). • Day of week (RTCDOW), which runs from 0–6. • Day of month (RTCDAY). • Month (RTCMON). V SUPRAJA

85 • Year (RTCYEARL), assuming BCD format.
• Century (RTCYEARH), assuming BCD format The registers are arranged in pairs that can also be accessed as words. For example, RTCYEAR = RTCYEARH:RTCYEARL and RTCTIM0 = RTCMIN:RTCSEC. Their values can be stored either as normal binary numbers or as BCD. The latter is more convenient for driving a display and is selected by setting the RTCBCD bit in RTCCTL. V SUPRAJA

86 V SUPRAJA

87 Setting the Real-Time Clock: State Machines
Introduction to State Machines Circle Indicates State and Arrow Indicates Transition. Dotted Circle with arrow indicates Initial State. V SUPRAJA

88 State Diagram of Read Input from a Switch
It enters the LedOff state after initialization. The initial transition should really have an Extinguish LED action to ensure that the LED is initially switched off. The state machine is called periodically. While the button remains up, the state machine takes the transition labeled !Button and therefore remains in the LedOff state. If the button is pressed when the state machine is called, it performs the Light LED action and makes a transition to the LedOn state. The state machine remains in the LedOn state until the button is released, when it carries out the Extinguish LED action and returns to the LedOff state. V SUPRAJA

89 V SUPRAJA

90 Example 2: The LED should be turned on when the button is next pressed, then turned off after the button has been released and pressed again. Now there are four states of the system instead of two because the LED can be either on or off when the button is either up or down. V SUPRAJA

91 A State Machine to Set the Time of the Clock
Instructions for Setting the Time 1. Hold down the Mode button until the minutes vanish and the hours flash on the display. 2. Hold down the Advance button until the hours display shows the correct time. 3. Hold down the Mode button until the hours vanish and the minutes flash on the display. 4. Hold down the Advance button until the minutes display shows the correct time. 5. Hold down the Mode button until the full display reappears. The clock restarts at the time shown with 0 seconds when the button is released. V SUPRAJA

92 The time should be advanced if only the Advance button is down.
The state machine should move on to the next state if only the Mode button is down. The display should flash if neither button is down. V SUPRAJA

93 V SUPRAJA

94 MSP stands for “mixed signal processor” and most MSP430s are used in applications that handle both analog and digital data The MSP430 offers three methods of conversion with quite different characteristics. Comparator: Simple and cheap module that cannot perform a conversion by itself but is usually used with Timer_A to measure the time-constant of an external RC circuit. There are two versions, Comparator_A and Comparator_A+. Successive-approximation ADC: The general-purpose type of ADC for many years. It is fast and relatively straightforward to understand. There are two versions, ADC10 and ADC12, which give 10 and 12 bits of output. Sigma–delta ADC:A more complicated ADC that works in a quite different way to give higher resolution (more bits) but at a slower speed. There are two versions, SD16 and SD16_A, both of which give a 16-bit output. V SUPRAJA

95 COMPARATOR A An analog comparator compares the voltages on its two input terminals, V+ and V−. Its output is high if V+ >V− and low if V+ <V−. Thus it provides a basic bridge between the analog and digital domains and acts like a 1-bit ADC. Architecture of Comparator A+ V SUPRAJA

96 reference can also be connected to V+.
These are the main features of Comparator_A+. The entire module is switched on and off with the CAON bit. It is off by default to save current. The non inverting input V+ can be connected to external signals CA0–CA2 or left without an external connection. This is selected using bits P2CA4 and P2CA0. An internal voltage reference can also be connected to V+. Similarly, the inverting input V− can be connected to external signals CA1–CA7 (but not CA0) or left unconnected, according to bits P2CA[3:1]. It can also be connected to an internal reference. The internal reference voltage VCAREF can be chosen from ¼ VCC, ½ VCC or a nominally fixed voltage from a transistor, Vdiode. This is selected with the CAREFx bits. It can be applied to either input of the comparator according to the CARSEL bit. V SUPRAJA

97 The raw output of the comparator can optionally be filtered through an RC circuit to reduce oscillations in the signal, which may arise if the inputs vary slowly. This is selected with the CAF bit. The output is brought to an external pin CAOUT. It is also connected internally to capture input CCI1B of Timer_A, which allows precise timing without delays that would be introduced if software were needed for communication between the modules. The flag CAIFG is raised on either a rising or falling edge of the comparator output, selected with the CAIES bit. This can in turn request an interrupt if CAIE is set. Comparator_A+ has its own interrupt vector and the flag is cleared automatically when the interrupt is serviced. V SUPRAJA

98 The ADC10 Successive-Approximation ADC
There are two SAR ADC modules available on the MSP430, the ADC10 and ADC12. The ADC12 has a more elaborate set of registers for storing batches of results. It needs external capacitors on its voltage reference. >Interrupts are more complicated in the ADC12 V SUPRAJA

99 Architecture of the ADC10
V SUPRAJA

100 the heart of the ADC10 is a 10-bit, switched-capacitor, SAR core.
Figure shows a simplified block diagram of the ADC10 in the F20x2; there are more inputs in larger devices. Core: the heart of the ADC10 is a 10-bit, switched-capacitor, SAR core. It is guaranteed monotonic with no missing codes. The ADC10ON bit enables the core and a flag ADC10BUSY is set while sampling and conversion is in progress. The result is written to ADC10MEM in a choice of two formats, selected with the ADC10DF bit: • The default is straightforward, right-justified binary in the range 0x0000–0x03FF.Zero corresponds to the bottom of the input range. • lowest 6 bits are always clear and bit 15 gives the sign. V SUPRAJA

101 Clock: This can be taken from MCLK, SMCLK, ACLK, or the module’s internal oscillator ADC10OSC, selected with the ADC10SSELx bits. It must lie within the range 0.45–6.3MHz for the F20x2. The internal oscillator runs nominally at 5MHz but the specification gives a spread of 3.7 to 6.3MHz. It is automatically enabled when needed and disabled when conversions have finished. This makes it the most convenient source for most applications. The frequency of the clock can be divided by 2, 3, , 7, 8 by configuring the ADC10DIVx bits. The output of the divider is labeled ADC10CLK and feeds both the SAR core and sample-and-hold blocks. V SUPRAJA

102 Sample and Hold: a sample and hold (S/H, also "follow-and-hold") circuit is an analog device that samples (captures, grabs) the voltage of a continuously varying analog signal  and holds (locks, freezes) its value at a constant level for a specified minimum period of time.  V SUPRAJA

103 Input Selection Conversion Trigger
A multiplexer selects the input from eight external pins A0–A7 (more in larger MSP430s) and four internal connections. Two of the internal connections are for optional, The other two internal connections are A10 to a temperature sensor and A11 to Vmid = ½ (VCC+VSS), which is provided to monitor the supply voltage. External reference voltages, which share the pins for A3 and A4 in many devices. These are not shown in Figure. Conversion Trigger A conversion can be triggered in two ways provided that the ENC bit is set. The first is by setting the ADC10SC bit from software (it clears again automatically). This has the usual problem that the timing is not precise, which leads to errors in the converted value of a signal that varies rapidly V SUPRAJA

104 Timing and Current Consumption of the ADC10
Interrupts The interrupt flag ADC10IFG is raised when the result is written to ADC10MEM except when the DTC is used, when it is set after a block has been completed Timing and Current Consumption of the ADC10 Conversions take 13 cycles of ADC10CLK. The final cycle is used to copy the result into ADC10MEM and adjust its format if necessary. It is interesting to look at the currents drawn by the different blocks within the ADC10. • 0.6mA for the SAR core. • 0.25mA for the internal reference alone, without the buffer. • 0.5mA for the buffer at reduced speed • 1.1mA for the buffer at full speed V SUPRAJA

105 Basic Operation of the ADC10
1. Configure the ADC10, including the ADC10ON bit to enable the module. The ENC bit must be clear during this operation because most bits in ADC10CTL0 and ADC10CTL1 can be changed only when ENC = Set the ENC bit to enable a conversion. This cannot be done while the module is being configured in the previous step. 3. Trigger the conversion, either by setting the ADC10SC bit or by an edge from Timer_A. V SUPRAJA

106 DMA controller features
Up to eight independent transfer channels Configurable DMA channel priorities Requires only two MCLK clock cycles per transfer Byte or word and mixed byte and word transfer capability Block sizes up to bytes or words Configurable transfer trigger selections Selectable-edge or level-triggered transfer Four addressing modes Single, block, or burst-block transfer modes V SUPRAJA

107 V SUPRAJA

108 Data Transfer Direct Memory Access (DMA)
The DMA controller transfers data from one address to another, without CPU intervention, across the entire address range. Using the DMA controller can increase the throughput of peripheral modules V SUPRAJA

109 DMA Addressing Modes: The DMA controller has four addressing modes
The addressing modes are: Fixed address to fixed address Fixed address to block of addresses Block of addresses to fixed address Block of addresses to block of addresses V SUPRAJA

110 DMA Transfer Modes V SUPRAJA

111 Single Transfer V SUPRAJA

112 V SUPRAJA

113 Burst-Block Transfer V SUPRAJA


Download ppt "UNIT – IV Interrupts V SUPRAJA."