Presentation is loading. Please wait.

Presentation is loading. Please wait.

EVAR Overview and stent-graft implantation in complex iliac anatomy

Similar presentations


Presentation on theme: "EVAR Overview and stent-graft implantation in complex iliac anatomy"— Presentation transcript:

1 EVAR Overview and stent-graft implantation in complex iliac anatomy
Angiomed Workshop Deineka Conference Room 22TH JUNE 2019 Dr. G. Kalender DRK Kliniken Berlin

2 Anaconda Stentgraft modular design flexible safe repositionable
easily probed with magnet wire Dr. G. Kalender

3 Indications Morphology suitable for Endovascular Aneurysm Repair (EVAR) Proximal aortic neck length of ≥15mm with non-significant calcification and/or thrombus Native proximal neck diameter 17,5- 31 mm Anaconda™ ONE-LOK™ Adequate iliac or femoral vessel access Native iliac artery diameters of 8,5- 21 mm Distal Fixation Length Of ≥20mm Dr. G. Kalender

4 Modular concept wide range of main bodys and iliac legs
durable ultrathin- polyester ring- stent design (nitinol) Dr. G. Kalender

5 contralateral radiopaque markers leg docking radiopaque
bifurcated main body proximal ring contralateral radiopaque markers secondary ring valley hooks peek hooks leg docking radiopaque distal radiopaque marker contralateral cannulation flare with radiopaque markers Dr. G. Kalender

6 proximal radiopaque marker distal radiopaque marker
Iliac leg proximal radiopaque marker individual ring stents with radiopaque alignment markers distal radiopaque marker Dr. G. Kalender

7 Iliac leg – flared und tapered
proximal radiopaque marker transition marker distal radiopaque marker Dr. G. Kalender

8 fast and easy cannulation
patented magnet wire cannulation Dr. G. Kalender

9 Fully repositionable Dr. G. Kalender

10 Range of sizes bifurcated main body diameter 21,5 – 34 mm length 65 mm
Iliac leg diameter – 23 mm length – 140 mm Dr. G. Kalender

11 Anaconda Stentgraft System
NEW ONE-LOK™ BODY: Additional ring stents: maximize the lumen und blood flow large lumen for ipsilateral cannulation standard diameter in the docking zone indicated to treat infra-renal neck angulations > 90° Dr. G. Kalender

12 Proactive Sealing System
12 Proactive Sealing System Excellent sealing function - dual, proximal ring stent design with hooks - security against stent graft migration Dr. G. Kalender

13 FDA Clinical Trial Phase II
One Year Results of the Vascutek Anaconda™. ONE-LOK EVAR trial. Christopher Kwolek, MD. Randy Moore, MD. On behalf of the Anaconda™ Investigators  23 hospitals (18 USA, 5 Canada), 195 patients, >15 mm neck of aneurysm, <60° angulation 98 % technical success , no conversion 0% mortality, 100 % open iliac leg 98% no endoleak Typ I oder III Typ II endoleak: 32 % (30 Tagen), 26% (1Jahr) summary: Anaconda- stentgraft- safe and effektive after 12 months Dr. G. Kalender

14 Fenestrated Anaconda™
Body section without stents: maximise the available area for fenestrations optimal flexibility for varying patient anatomies fully repositionable system for optimal positioning no deformation of fenestration by stent material Dr. G. Kalender

15 Fenestrated Anaconda™
patented magnet system: significantly reduce bifurcate body cannulation time dual proximal ring stent design with hooks provides excellent sealing function multiple independent ring stent design provides maximum flexibility for varying patient anatomies minimises the potential for kinking Dr. G. Kalender

16 Fenestrated Anaconda™
> 3000 implantations > 8000 target vessels since 06/2010 Vacutek Terumo News, fenestrated anaconda, Jahrgang XVIV 2015 Dr. G. Kalender

17 Custom Made Leg Example Concepts
Dr. G. Kalender

18 Design Possibilitys Sealingring, Hooks, Fenestrations…
Dr. G. Kalender

19 Access Possibilitys Dr. G. Kalender

20 POST-OP Pictures Dr. G. Kalender

21 Device Customisations
Pleating Reduces fabric in region of aortic narrowing Dr. G. Kalender

22 Additional Fenestration Support Tapered Graft
Helps to alleviate excess fabric overlapping with fenestrations Reduces the fabric diameter in cases of more extreme narrowing Dr. G. Kalender

23 Flared Graft Extra-long Body
Increases the fabric diameter in cases of more extreme widening 90-100mm long. Required joining ring to attach two pieces of fabric together and the contralateral flare is removed. Dr. G. Kalender

24 Legs Lateral Useful when close to the bifurcation of an existing device or aorta Dr. G. Kalender

25 Dr. G. Kalender


Download ppt "EVAR Overview and stent-graft implantation in complex iliac anatomy"

Similar presentations


Ads by Google